Development of the R2SUNED Code System for Shutdown Dose Rate Calculations

被引:46
|
作者
Sauvan, P. [1 ]
Catalan, J. P. [1 ]
Ogando, F. [1 ]
Juarez, R. [1 ]
Sanz, J. [1 ]
机构
[1] UNED, Dept Ingn Energet, Madrid 28040, Spain
关键词
Coupled radiation transport-activation calculations; DEMO; fusion neutronics; ITER; MCNP; R2S methodology; shutdown dose rate;
D O I
10.1109/TNS.2015.2507138
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
R2SUNED is a code system implementing the meshbased Rigorous-two-step method for shutdown dose rates calculations, making use of MCNP and ACAB codes. In addition to the most relevant features of state-of-the-art R2S systems, novel and unique features have been implemented in R2SUNED to overcome limitations common to the current mesh-based R2S implementations. One of particular interest is the cell-under-voxel approach intended to address most of the issues associated with the conventional averaging technique used in the neutron flux determination. The underlying idea is to identify the cells enclosed in each voxel and calculate the average value of the neutron flux within each cell fraction. Subsequently, the activation of each material, filling the cell delimited by the voxel, is calculated using the neutron flux evaluated in the corresponding cell. This capability enables to properly resolve the strong spatial gradients of the neutron flux independently of geometrical considerations. Another relevant feature is that a flexible decay gamma source sampling has been incorporated to assure an efficient decay gamma transport in a vast diversity of problems. A verification of R2SUNED has been addressed on the ITER computational shutdown dose rate benchmark. It is highlighted both the limitations of voxel averaged neutron flux standard approach, and the ability of R2SUNED to overcome this issue. The excellent agreement of the results with those obtained using a mesh matching perfectly the geometry tells that R2SUNED performs correctly. Finally, a description of the most representative applications carried out with R2SUNED is provided for fusion relevant facilities.
引用
收藏
页码:375 / 384
页数:10
相关论文
共 50 条
  • [1] Shutdown dose rate calculation code system and its application to EAST tokamak
    Wu, Liangliang
    Yang, Qi
    Zou, Jun
    Wang, Guozhong
    He, Tao
    FUSION ENGINEERING AND DESIGN, 2012, 87 (7-8) : 1315 - 1318
  • [2] Progress in development of advanced D1S dynamic code for three-dimensional shutdown dose rate calculations
    Mariano, Giovanni
    Flammini, Davide
    Fonnesu, Nicola
    Moro, Fabio
    Villari, Rosaria
    FUSION ENGINEERING AND DESIGN, 2020, 157
  • [3] Development of shutdown dose rate calculation code based on cosRMC and application to benchmark analysis
    Zhang, Xian
    Liu, Shichang
    Lu, Peng
    Zhang, Xiaokang
    Zheng, Yu
    Chen, Yixue
    Liu, Songlin
    FUSION ENGINEERING AND DESIGN, 2021, 173
  • [4] CALCULATION CODE FOR PREDICTING SHUTDOWN DOSE-RATE OF BWR
    MATSUSHIMA, Y
    MEGURO, Y
    UCHIDA, S
    KITAMURA, M
    YUSA, H
    OHSUMI, K
    MIKI, M
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1979, 32 (JUN): : 759 - 760
  • [5] Shutdown dose rate calculations with modified DEMO single sector model
    Lengar, Igor
    Kotnik, Domen
    Kos, Bor
    Cufar, Aljaz
    Bachmann, Christian
    Snoj, Luka
    FUSION ENGINEERING AND DESIGN, 2021, 171
  • [6] Sensitivity of R2Smesh shutdown dose rate results on the mesh resolution
    Lu, Peng
    Pereslavtsev, Pavel
    Fischer, Ulrich
    Wegmann, Christian
    FUSION ENGINEERING AND DESIGN, 2018, 126 : 15 - 23
  • [7] Development and validation of fully open-source R2S shutdown dose rate capabilities in OpenMC
    Peterson, Ethan E.
    Romano, Paul K.
    Shriwise, Patrick C.
    Myers, Patrick A.
    NUCLEAR FUSION, 2024, 64 (05)
  • [8] Nuclear waste analysis of JET, utilising shutdown dose rate code enhancements
    Chohan, Hari
    Eade, Tim
    Turner, Andrew
    Gilbert, Mark
    Naish, Jonathan
    Turner, Anthony
    Berry, Tom
    Packer, Lee
    FUSION ENGINEERING AND DESIGN, 2023, 194
  • [9] Benchmarking of Monte Carlo based shutdown dose rate calculations for applications to jet
    Petrizzi, L
    Batistoni, P
    Fischer, U
    Loughlin, M
    Pereslavtsev, P
    Villari, R
    RADIATION PROTECTION DOSIMETRY, 2005, 115 (1-4) : 80 - 85
  • [10] Rigorous MCNP based shutdown dose rate calculations: computational scheme, verification calculations and application to ITER
    Chen, Y
    Fischer, U
    FUSION ENGINEERING AND DESIGN, 2002, 63-64 : 107 - 114