Accelerated free-breathing whole-heart 3D T2 mapping with high isotropic resolution

被引:13
|
作者
Bustin, Aurelien [1 ]
Milotta, Giorgia [1 ]
Ismail, Tevfik F. [1 ]
Neji, Radhouene [1 ,2 ]
Botnar, Rene M. [1 ,3 ]
Prieto, Claudia [1 ,3 ]
机构
[1] Kings Coll London, Sch Biomed Engn & Imaging Sci, Dept Biomed Engn, London, England
[2] Siemens Healthcare, MR Res Collaborat, Frimley, England
[3] Pontificia Univ Catolica Chile, Escuela Ingn, Santiago, Chile
基金
英国工程与自然科学研究理事会;
关键词
fast imaging; isotropic resolution; motion correction; myocardial T-2 mapping; T-2; quantification; SATURATION-RECOVERY; MYOCARDIAL T-1; T2; T1; QUANTIFICATION; ANGIOGRAPHY; ACCURACY;
D O I
10.1002/mrm.27989
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To enable free-breathing whole-heart 3D T-2 mapping with high isotropic resolution in a clinically feasible and predictable scan time. This 3D motion-corrected undersampled signal matched (MUST) T-2 map is achieved by combining an undersampled motion-compensated T-2-prepared Cartesian acquisition with a high-order patch-based reconstruction. Methods The 3D MUST-T-2 mapping acquisition consists of an electrocardiogram-triggered, T-2-prepared, balanced SSFP sequence with nonselective saturation pulses. Three undersampled T-2-weighted volumes are acquired using a 3D Cartesian variable-density sampling with increasing T-2 preparation times. A 2D image-based navigator is used to correct for respiratory motion of the heart and allow 100% scan efficiency. Multicontrast high-dimensionality undersampled patch-based reconstruction is used in concert with dictionary matching to generate 3D T-2 maps. The proposed framework was evaluated in simulations, phantom experiments, and in vivo (10 healthy subjects, 2 patients) with 1.5-mm(3) isotropic resolution. Three-dimensional MUST-T-2 was compared against standard multi-echo spin-echo sequence (phantom) and conventional breath-held single-shot 2D SSFP T-2 mapping (in vivo). Results Three-dimensional MUST-T-2 showed high accuracy in phantom experiments (R-2 > 0.99). The precision of T-2 values was similar for 3D MUST-T-2 and 2D balanced SSFP T-2 mapping in vivo (5 +/- 1 ms versus 4 +/- 2 ms, P = .52). Slightly longer T-2 values were observed with 3D MUST-T-2 in comparison to 2D balanced SSFP T-2 mapping (50.7 +/- 2 ms versus 48.2 +/- 1 ms, P < .05). Preliminary results in patients demonstrated T-2 values in agreement with literature values. Conclusion The proposed approach enables free-breathing whole-heart 3D T-2 mapping with high isotropic resolution in about 8 minutes, achieving accurate and precise T-2 quantification of myocardial tissue in a clinically feasible scan time.
引用
收藏
页码:988 / 1002
页数:15
相关论文
共 50 条
  • [1] 3D Whole-heart free-breathing qBOOST-T2 mapping
    Milotta, Giorgia
    Ginami, Giulia
    Bustin, Aurelien
    Neji, Radhouene
    Prieto, Claudia
    Botnar, Rene M.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (05) : 1673 - 1687
  • [2] Fast, whole-heart, free-breathing 3D T2 mapping at 3T with application to myocardial edema imaging
    Hsin-Jung Yang
    Jianing Pang
    Behzad Sharif
    Avinash Kali
    Xiaoming Bi
    Ivan Cokic
    Debiao Li
    Rohan Dharmakumar
    Journal of Cardiovascular Magnetic Resonance, 17 (Suppl 1)
  • [3] Free-breathing 3D whole-heart joint T1/T2 mapping and water/fat imaging at 0.55 T
    Si, Dongyue
    Crabb, Michael G.
    Kunze, Karl P.
    Littlewood, Simon J.
    Prieto, Claudia
    Botnar, Rene M.
    MAGNETIC RESONANCE IN MEDICINE, 2024, 92 (04) : 1511 - 1524
  • [4] Evaluation of myocarditis with a free-breathing three-dimensional isotropic whole-heart joint T1 and T2 mapping sequence
    Hua, Alina
    Velasco, Carlos
    Munoz, Camila
    Milotta, Giorgia
    Fotaki, Anastasia
    Bosio, Filippo
    Granlund, Inka
    Sularz, Agata
    Chiribiri, Amedeo
    Kunze, Karl P.
    Botnar, Rene
    Prieto, Claudia
    Ismail, Tevfik F.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2024, 26 (02)
  • [5] Fast, Free-Breathing, Whole-Heart Cardiac Magnetic Resonance T2 Mapping for Myocardial Edema Imaging
    Yang, Hsin-Jung
    Sharif, Behzad
    Pang, Jianing
    Kali, Avinash
    Bi, Xiaoming
    Cokic, Ivan
    Li, Debiao
    Dharmakumar, Rohan
    CIRCULATION, 2014, 130
  • [6] High-Spatial-Resolution 3D Whole-Heart MRI T2 Mapping for Assessment of Myocarditis
    Bustin, Aurelien
    Hua, Alina
    Milotta, Giorgia
    Jaubert, Olivier
    Hajhosseiny, Reza
    Ismail, Tevfik F.
    Botnar, Rene M.
    Prieto, Claudia
    RADIOLOGY, 2021, 298 (03) : 578 - 586
  • [7] Accelerated high-resolution free-breathing 3D whole-heart T2-prepared black-blood and bright-blood cardiovascular magnetic resonance
    Teresa Correia
    Giulia Ginami
    Imran Rashid
    Giovanna Nordio
    Reza Hajhosseiny
    Tevfik F. Ismail
    Radhouene Neji
    René M. Botnar
    Claudia Prieto
    Journal of Cardiovascular Magnetic Resonance, 22
  • [8] Accelerated high-resolution free-breathing 3D whole-heart T2-prepared black-blood and bright-blood cardiovascular magnetic resonance
    Correia, Teresa
    Ginami, Giulia
    Rashid, Imran
    Nordio, Giovanna
    Hajhosseiny, Reza
    Ismail, Tevfik F.
    Neji, Radhouene
    Botnar, Rene M.
    Prieto, Claudia
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2020, 22 (01)
  • [9] Accelerated 3D free-breathing high-resolution myocardial T1ρ mapping at 3 Tesla
    Qi, Haikun
    Lv, Zhenfeng
    Hu, Junpu
    Xu, Jian
    Botnar, Rene
    Prieto, Claudia
    Hu, Peng
    MAGNETIC RESONANCE IN MEDICINE, 2022, 88 (06) : 2520 - 2531
  • [10] Simultaneous whole-liver water T1 and T2 mapping with isotropic resolution during free-breathing
    Stelter, Jonathan
    Weiss, Kilian
    Steinhelfer, Lisa
    Spieker, Veronika
    Moquillaza, Elizabeth Huaroc
    Zhang, Weitong
    Makowski, Marcus R.
    Schnabel, Julia A.
    Kainz, Bernhard
    Braren, Rickmer F.
    Karampinos, Dimitrios C.
    NMR IN BIOMEDICINE, 2024, 37 (12)