Accelerated high-resolution free-breathing 3D whole-heart T2-prepared black-blood and bright-blood cardiovascular magnetic resonance

被引:8
|
作者
Correia, Teresa [1 ]
Ginami, Giulia [1 ]
Rashid, Imran [1 ]
Nordio, Giovanna [1 ]
Hajhosseiny, Reza [1 ]
Ismail, Tevfik F. [1 ]
Neji, Radhouene [1 ,2 ]
Botnar, Rene M. [1 ,3 ]
Prieto, Claudia [1 ,3 ]
机构
[1] Kings Coll London, St Thomas Hosp, Sch Biomed Engn & Imaging Sci, London, England
[2] Siemens Healthcare Ltd, MR Res Collaborat, Frimley, England
[3] Pontificia Univ Catolica Chile, Escuela Ingn, Santiago, Chile
基金
英国工程与自然科学研究理事会;
关键词
Late gadolinium enhancement (LGE); Coronary magnetic resonance angiography (CMRA); Black-blood; Compressed sensing; Image navigator; Respiratory motion compensation; SENSITIVE INVERSION-RECOVERY; IRREVERSIBLE INJURY; MR; ENHANCEMENT; RECONSTRUCTION; VISUALIZATION; DISTINCTION; SCAR;
D O I
10.1186/s12968-020-00691-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background The free-breathing 3D whole-heart T-2-prepared Bright-blood and black-blOOd phase SensiTive inversion recovery (BOOST) cardiovascular magnetic resonance (CMR) sequence was recently proposed for simultaneous bright-blood coronary CMR angiography and black-blood late gadolinium enhancement (LGE) imaging. This sequence enables simultaneous visualization of cardiac anatomy, coronary arteries and fibrosis. However, high-resolution (< 1.4 x 1.4 x 1.4 mm(3)) fully-sampled BOOST requires long acquisition times of similar to 20 min. Methods In this work, we propose to extend a highly efficient respiratory-resolved motion-corrected reconstruction framework (XD-ORCCA) to T-2-prepared BOOST to enable high-resolution 3D whole-heart coronary CMR angiography and black-blood LGE in a clinically feasible scan time. Twelve healthy subjects were imaged without contrast injection (pre-contrast BOOST) and 10 patients with suspected cardiovascular disease were imaged after contrast injection (post-contrast BOOST). A quantitative analysis software was used to compare accelerated pre-contrast BOOST against the fully-sampled counterpart (vessel sharpness and length of the left and right coronary arteries). Moreover, three cardiologists performed diagnostic image quality scoring for clinical 2D LGE and both bright- and black-blood 3D BOOST imaging using a 4-point scale (1-4, non-diagnostic-fully diagnostic). A two one-sided test of equivalence (TOST) was performed to compare the pre-contrast BOOST images. Nonparametric TOST was performed to compare post-contrast BOOST image quality scores. Results The proposed method produces images from 3.8 x accelerated non-contrast-enhanced BOOST acquisitions with comparable vessel length and sharpness to those obtained from fully- sampled scans in healthy subjects. Moreover, in terms of visual grading, the 3D BOOST LGE datasets (median 4) and the clinical 2D counterpart (median 3.5) were found to be statistically equivalent (p < 0.05). In addition, bright-blood BOOST images allowed for visualization of the proximal and middle left anterior descending and right coronary sections with high diagnostic quality (mean score > 3.5). Conclusions The proposed framework provides high-resolution 3D whole-heart BOOST images from a single free-breathing acquisition in similar to 7 min.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Accelerated high-resolution free-breathing 3D whole-heart T2-prepared black-blood and bright-blood cardiovascular magnetic resonance
    Teresa Correia
    Giulia Ginami
    Imran Rashid
    Giovanna Nordio
    Reza Hajhosseiny
    Tevfik F. Ismail
    Radhouene Neji
    René M. Botnar
    Claudia Prieto
    Journal of Cardiovascular Magnetic Resonance, 22
  • [2] Free-breathing 3D whole-heart black-blood imaging with motion sensitized driven equilibrium
    Srinivasan, Subashini
    Hu, Peng
    Kissinger, Kraig V.
    Goddu, Beth
    Goepfert, Lois
    Schmidt, Ehud J.
    Kozerke, Sebastian
    Nezafat, Reza
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2012, 36 (02) : 379 - 386
  • [3] Accelerated free-breathing whole-heart 3D T2 mapping with high isotropic resolution
    Bustin, Aurelien
    Milotta, Giorgia
    Ismail, Tevfik F.
    Neji, Radhouene
    Botnar, Rene M.
    Prieto, Claudia
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (03) : 988 - 1002
  • [4] Advantage in Bright-blood and Black-blood Magnetic Resonance Imaging with High-resolution for Analysis of Carotid Atherosclerotic Plaques
    Li Mei
    Le Wei-Jie
    Tao Xiao-Feng
    Li Ming-Hua
    Li Yue-Hua
    Qu Nan
    中华医学杂志英文版, 2015, 128 (18) : 2478 - 2484
  • [5] Advantage in Bright-blood and Black-blood Magnetic Resonance Imaging with High-resolution for Analysis of Carotid Atherosclerotic Plaques
    Li, Mei
    Le, Wei-Jie
    Tao, Xiao-Feng
    Li, Ming-Hua
    Li, Yue-Hua
    Qu, Nan
    CHINESE MEDICAL JOURNAL, 2015, 128 (18) : 2478 - 2484
  • [6] Simultaneous 3D whole-heart bright-blood and black blood imaging for cardiovascular anatomy and wall assessment with interleaved T2prep-IR
    Milotta, Giorgia
    Ginami, Giulia
    Cruz, Gastao
    Neji, Radhouene
    Prieto, Claudia
    Botnar, Rene M.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 82 (01) : 312 - 325
  • [7] Non-contrast enhanced simultaneous 3D whole-heart bright-blood pulmonary veins visualization and black-blood quantification of atrial wall thickness
    Ginami, Giulia
    Lopez, Karina
    Mukherjee, Rahul K.
    Neji, Radhouene
    Munoz, Camila
    Roujol, Sebastien
    Mountney, Peter
    Razavi, Reza
    Botnar, Rene M.
    Prieto, Claudia
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (02) : 1066 - 1079
  • [8] 3D whole-heart phase sensitive inversion recovery CMR for simultaneous black-blood late gadolinium enhancement and bright-blood coronary CMR angiography
    Giulia Ginami
    Radhouene Neji
    Imran Rashid
    Amedeo Chiribiri
    Tevfik F. Ismail
    René M. Botnar
    Claudia Prieto
    Journal of Cardiovascular Magnetic Resonance, 19
  • [9] 3D whole-heart phase sensitive inversion recovery CMR for simultaneous black-blood late gadolinium enhancement and bright-blood coronary CMR angiography
    Ginami, Giulia
    Neji, Radhouene
    Rashid, Imran
    Chiribiri, Amedeo
    Ismail, Tevfik F.
    Botnar, Rene M.
    Prieto, Claudia
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2017, 19
  • [10] 3D Whole-heart free-breathing qBOOST-T2 mapping
    Milotta, Giorgia
    Ginami, Giulia
    Bustin, Aurelien
    Neji, Radhouene
    Prieto, Claudia
    Botnar, Rene M.
    MAGNETIC RESONANCE IN MEDICINE, 2020, 83 (05) : 1673 - 1687