Accelerated free-breathing whole-heart 3D T2 mapping with high isotropic resolution

被引:13
|
作者
Bustin, Aurelien [1 ]
Milotta, Giorgia [1 ]
Ismail, Tevfik F. [1 ]
Neji, Radhouene [1 ,2 ]
Botnar, Rene M. [1 ,3 ]
Prieto, Claudia [1 ,3 ]
机构
[1] Kings Coll London, Sch Biomed Engn & Imaging Sci, Dept Biomed Engn, London, England
[2] Siemens Healthcare, MR Res Collaborat, Frimley, England
[3] Pontificia Univ Catolica Chile, Escuela Ingn, Santiago, Chile
基金
英国工程与自然科学研究理事会;
关键词
fast imaging; isotropic resolution; motion correction; myocardial T-2 mapping; T-2; quantification; SATURATION-RECOVERY; MYOCARDIAL T-1; T2; T1; QUANTIFICATION; ANGIOGRAPHY; ACCURACY;
D O I
10.1002/mrm.27989
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose To enable free-breathing whole-heart 3D T-2 mapping with high isotropic resolution in a clinically feasible and predictable scan time. This 3D motion-corrected undersampled signal matched (MUST) T-2 map is achieved by combining an undersampled motion-compensated T-2-prepared Cartesian acquisition with a high-order patch-based reconstruction. Methods The 3D MUST-T-2 mapping acquisition consists of an electrocardiogram-triggered, T-2-prepared, balanced SSFP sequence with nonselective saturation pulses. Three undersampled T-2-weighted volumes are acquired using a 3D Cartesian variable-density sampling with increasing T-2 preparation times. A 2D image-based navigator is used to correct for respiratory motion of the heart and allow 100% scan efficiency. Multicontrast high-dimensionality undersampled patch-based reconstruction is used in concert with dictionary matching to generate 3D T-2 maps. The proposed framework was evaluated in simulations, phantom experiments, and in vivo (10 healthy subjects, 2 patients) with 1.5-mm(3) isotropic resolution. Three-dimensional MUST-T-2 was compared against standard multi-echo spin-echo sequence (phantom) and conventional breath-held single-shot 2D SSFP T-2 mapping (in vivo). Results Three-dimensional MUST-T-2 showed high accuracy in phantom experiments (R-2 > 0.99). The precision of T-2 values was similar for 3D MUST-T-2 and 2D balanced SSFP T-2 mapping in vivo (5 +/- 1 ms versus 4 +/- 2 ms, P = .52). Slightly longer T-2 values were observed with 3D MUST-T-2 in comparison to 2D balanced SSFP T-2 mapping (50.7 +/- 2 ms versus 48.2 +/- 1 ms, P < .05). Preliminary results in patients demonstrated T-2 values in agreement with literature values. Conclusion The proposed approach enables free-breathing whole-heart 3D T-2 mapping with high isotropic resolution in about 8 minutes, achieving accurate and precise T-2 quantification of myocardial tissue in a clinically feasible scan time.
引用
收藏
页码:988 / 1002
页数:15
相关论文
共 50 条
  • [21] Optimization of coronary whole-heart MRA free-breathing technique at 3 Tesla
    Gharib, Ahmed M.
    Abd-Elmoniem, Khaled Z.
    Herzka, Daniel A.
    Ho, Vincent B.
    Locklin, Julie
    Tzatha, Efstathia
    Stuber, Matthias
    Pettigrew, Roderic I.
    MAGNETIC RESONANCE IMAGING, 2011, 29 (08) : 1125 - 1130
  • [22] A study of in vitro and in vivo MR of free-breathing whole-heart 3D coronary angiography using parallel imaging
    Jin, Hang
    Zeng, Meng-Su
    Ge, Mei-Ying
    Yang, Shan
    Chen, Cai-Zhong
    Shen, Ji-Zhang
    Li, Ren-Chen
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2009, 25 : 121 - 129
  • [23] Free-Breathing Whole-Heart Coronary MRA: Motion Compensation Integrated into 3D Cartesian Compressed Sensing Reconstruction
    Forman, Christoph
    Grimm, Robert
    Hutter, Jana Maria
    Maier, Andreas
    Hornegger, Joachim
    Zenge, Michael O.
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2013, PT II, 2013, 8150 : 575 - 582
  • [24] Free-breathing T2* mapping for MR myocardial iron assessment at 3 T
    E. E. Nazarova
    G. V. Tereshchenko
    D. A. Kupriyanov
    N. S. Smetanina
    G. A. Novichkova
    European Radiology Experimental, 4
  • [25] Free-breathing T2*mapping for MR myocardial iron assessment at 3 T
    Nazarova, E. E.
    Tereshchenko, G., V
    Kupriyanov, D. A.
    Smetanina, N. S.
    Novichkova, G. A.
    EUROPEAN RADIOLOGY EXPERIMENTAL, 2020, 4 (01)
  • [26] A study of in vitro and in vivo MR of free-breathing whole-heart 3D coronary angiography using parallel imaging
    Hang Jin
    Meng-Su Zeng
    Mei-Ying Ge
    Shan Yang
    Cai-Zhong Chen
    Ji-Zhang Shen
    Ren-Chen Li
    The International Journal of Cardiovascular Imaging, 2009, 25 : 121 - 129
  • [27] Free-breathing whole-heart coronary MRA with 3D radial SSFP and self-navigated image reconstruction
    Stehning, C
    Börnert, P
    Nehrke, K
    Eggers, H
    Stuber, M
    MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (02) : 476 - 480
  • [28] Free-breathing 3D whole-heart coronary mra using respiratory motion-resolved sparse reconstruction
    Davide Piccini
    Li Feng
    Gabriele Bonanno
    Simone Coppo
    Jérôme Yerly
    Ruth P Lim
    Juerg Schwitter
    Daniel K Sodickson
    Ricardo Otazo
    Matthias Stuber
    Journal of Cardiovascular Magnetic Resonance, 18 (Suppl 1)
  • [29] Three-dimensional whole-heart T2 mapping at 3T
    Ding, Haiyan
    Fernandez-de-Manuel, Laura
    Schaer, Michael
    Schuleri, Karl H.
    Halperin, Henry
    He, Le
    Zviman, M. Muz
    Beinart, Roy
    Herzka, Daniel A.
    MAGNETIC RESONANCE IN MEDICINE, 2015, 74 (03) : 803 - 816
  • [30] Respiratory motion-compensated high-resolution 3D whole-heart T1ρ mapping
    Haikun Qi
    Aurelien Bustin
    Thomas Kuestner
    Reza Hajhosseiny
    Gastao Cruz
    Karl Kunze
    Radhouene Neji
    René M. Botnar
    Claudia Prieto
    Journal of Cardiovascular Magnetic Resonance, 22