Non-Parametric Bayesian Registration (NParBR) of Body Tumors in DCE-MRI Data

被引:2
|
作者
Pilutti, David [1 ]
Strumia, Maddalena [1 ,2 ,3 ]
Buechert, Martin [1 ]
Hadjidemetriou, Stathis [1 ,4 ]
机构
[1] Univ Med Ctr Freiburg, Dept Radiol Med Phys, D-79106 Freiburg, Germany
[2] German Canc Res Ctr, D-69121 Heidelberg, Germany
[3] German Canc Consortium DKTK, D-69121 Heidelberg, Germany
[4] Univ Hlth Sci, Inst Biomed Image Anal Med Informat & Technol, Dept Biomed Sci & Engn, A-6060 Hall In Tirol, Austria
关键词
Image time series analysis; joint histogram; non-parametric restoration; non-rigid registration; NONRIGID REGISTRATION; IMAGE REGISTRATION; MUTUAL-INFORMATION; BREAST; BRAIN; LIVER; DEFORMATION; SIMILARITY; ALGORITHM; MOTION;
D O I
10.1109/TMI.2015.2506338
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The identification of tumors in the internal organs of chest, abdomen, and pelvis anatomic regions can be performed with the analysis of Dynamic Contrast Enhanced Magnetic Resonance Imaging (DCE-MRI) data. The contrast agent is accumulated differently by pathologic and healthy tissues and that results in a temporally varying contrast in an image series. The internal organs are also subject to potentially extensive movements mainly due to breathing, heart beat, and peristalsis. This contributes to making the analysis of DCE-MRI datasets challenging as well as time consuming. To address this problem we propose a novel pairwise non-rigid registration method with a Non-Parametric Bayesian Registration (NParBR) formulation. The NParBR method uses a Bayesian formulation that assumes a model for the effect of the distortion on the joint intensity statistics, a non-parametric prior for the restored statistics, and also applies a spatial regularization for the estimated registration with Gaussian filtering. A minimally biased intra-dataset atlas is computed for each dataset and used as reference for the registration of the time series. The time series registration method has been tested with 20 datasets of liver, lungs, intestines, and prostate. It has been compared to the B-Splines and to the SyN methods with results that demonstrate that the proposed method improves both accuracy and efficiency.
引用
收藏
页码:1025 / 1035
页数:11
相关论文
共 50 条
  • [31] The Effectiveness of Deformable and Rigid-Body Registration On Estimating Pharmacokinetic Parameters of DCE-MRI of Esophageal Cancer Patients
    Lee, J.
    Ma, J.
    Carter, B.
    Court, L.
    Lin, S.
    MEDICAL PHYSICS, 2017, 44 (06) : 3099 - 3099
  • [32] MRI Denoising Based on a Non-Parametric Bayesian Image Sparse Representation Method
    Chen, Xian-bo
    Ding, Xing-hao
    Liu, Hui
    ADVANCED RESEARCH ON INFORMATION SCIENCE, AUTOMATION AND MATERIAL SYSTEM, PTS 1-6, 2011, 219-220 : 1354 - 1358
  • [33] NPBDREG: Uncertainty assessment in diffeomorphic brain MRI registration using a non-parametric Bayesian deep-learning based approach
    Khawaled, Samah
    Freiman, Moti
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 2022, 99
  • [34] Automatic Registration of DCE-MRI Prostate Images for Follow-up Comparison
    van Straaten, D.
    Zamecnik, P.
    Boehler, T.
    Laue, H.
    Wirtz, S.
    Hahn, H. K.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 4: IMAGE PROCESSING, BIOSIGNAL PROCESSING, MODELLING AND SIMULATION, BIOMECHANICS, 2010, 25 : 1452 - 1455
  • [35] Bayesian non-parametric models for spatially indexed data of mixed type
    Papageorgiou, Georgios
    Richardson, Sylvia
    Best, Nicky
    JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES B-STATISTICAL METHODOLOGY, 2015, 77 (05) : 973 - 999
  • [36] Bayesian non-parametric simultaneous quantile regression for complete and grid data
    Das, Priyam
    Ghosal, Subhashis
    COMPUTATIONAL STATISTICS & DATA ANALYSIS, 2018, 127 : 172 - 186
  • [37] A non-parametric Bayesian approach to decompounding from high frequency data
    Gugushvili S.
    van der Meulen F.
    Spreij P.
    Statistical Inference for Stochastic Processes, 2018, 21 (1) : 53 - 79
  • [38] Non-parametric Discrete Registration with Convex Optimisation
    Heinrich, Mattias P.
    Papiez, Bartlomiej W.
    Schnabel, Julia A.
    Handels, Heinz
    BIOMEDICAL IMAGE REGISTRATION (WBIR 2014), 2014, 8545 : 51 - 61
  • [39] Liver DCE-MRI registration based on sparse recovery of contrast agent curves
    Sun, Yuhang
    Zhu, Qiaoyun
    Huang, Meiyan
    Shen, Dinggang
    Zhou, Yujia
    Feng, Qianjin
    MEDICAL PHYSICS, 2021, 48 (11) : 6916 - 6929
  • [40] Multilevel Non-parametric Groupwise Registration in Cardiac MRI: Application to Explanted Porcine Hearts
    Mojica, Mia
    Pop, Mihaela
    Sermesant, Maxime
    Ebrahimi, Mehran
    STATISTICAL ATLASES AND COMPUTATIONAL MODELS OF THE HEART: ACDC AND MMWHS CHALLENGES, 2018, 10663 : 60 - 69