Mucin balls with wear of conventional and silicone hydrogel contact lenses

被引:24
|
作者
Tan, J
Keay, L
Jalbert, I
Naduvilath, TJ
Sweeney, DF [1 ]
Holden, BA
机构
[1] Univ New S Wales, Cooperat Res Ctr Eye Res & Technol, Sch Optometry & Vis Sci, Sydney, NSW 2052, Australia
[2] Univ New S Wales, Cornea & Contact Lens Res Unit, Sch Optometry & Vis Sci, Sydney, NSW 2052, Australia
关键词
soft contact lens; high Dk; silicone hydrogel; mucin balls; microdeposits; lipid plugs;
D O I
10.1097/00006324-200304000-00006
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To compare the frequency of mucin balls in subjects wearing conventional and high-Dk silicone hydrogel lenses during 12 months of extended-wear and to determine whether mucin balls are associated with any lens or subject characteristics. Methods. This study used data from a clinical trial where subjects wore either conventional hydrogel (N = 69, 6-night extended-wear) or silicone hydrogel (N = 70, 30-night extended-wear) contact lenses for 12 months. The number of mucin balls and other physiological responses, lens fit and performance, and subjective patient responses to lens wear were rated at each scheduled visit. Results. Subjects in the silicone hydrogel group had significantly greater numbers of mucin balls compared with subjects in the conventional hydrogel group over time (p < 0.001), but there were no significant differences in the percentage of subjects with mucin balls between the two groups. Increasing lens wettability, back surface deposits, and time of lens wear were associated with higher numbers of mucin balls in the conventional hydrogel group (p < 0.05); steeper corneal curvature and increasing lens wettability, back surface deposits, and number of microcysts were associated with higher numbers of mucin balls in the silicone hydrogel group (p < 0.05). Conclusions. This study indicates that a subset of the population is predisposed to develop mucin balls irrespective of the soft contact lens type worn, but lens type influences the degree of mucin ball formation. The relationship between lens wettability, back surface deposits, and steeper corneal curvature with mucin balls supports the hypothesis that the mechanical interaction of a lens with the surface layer of the epithelium and the tear film in association with the blinking forces of the lid is involved in mucin ball formation.
引用
收藏
页码:291 / 297
页数:7
相关论文
共 50 条
  • [41] Changes in UV-Visible Transmittance of Silicone-Hydrogel Contact Lenses Induced by Wear
    Lira, Madalena
    dos Santos Castanheira, Elisabete M.
    Santos, Livia
    Azeredo, Joana
    Yebra-Pimentel, Eva
    Real Oliveira, M. Elisabete C. D.
    OPTOMETRY AND VISION SCIENCE, 2009, 86 (04) : 332 - 339
  • [42] Influence of day and night wear on surface properties of silicone hydrogel contact lenses and bacterial adhesion
    Vermeltfoort, Pit B. J.
    Rustema-Abbing, Minie
    de Vries, Joop
    Bruinsma, Gerda M.
    Busscher, Henk J.
    van der Linden, Matthijs L.
    Hooymans, Johanna M. M.
    van der Mei, Henny C.
    CORNEA, 2006, 25 (05) : 516 - 523
  • [43] Reduction in ionic permeability of a silicone hydrogel contact lenses after one month of daily wear
    Ferreira da Silva, Ana Rita
    Compan, Vicente
    Gonzalez-Meijome, Jose M.
    MATERIALS RESEARCH EXPRESS, 2015, 2 (06):
  • [44] Contact Lens-Induced Circumlimbal Staining in Silicone Hydrogel Contact Lenses Worn on a Daily Wear Basis
    Maissa, Cecile
    Guillon, Michel
    Garofalo, Renee J.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2012, 38 (01): : 16 - 26
  • [45] Long term effects of the daily wear of senofilcon A silicone hydrogel contact lenses on eyelid tissues
    Guillon, Michel
    Maissa, Cecile
    CONTACT LENS & ANTERIOR EYE, 2012, 35 (03): : 112 - 117
  • [46] Photocrosslinkable hyaluronic acid as an internal wetting agent in model conventional and silicone hydrogel contact lenses
    Weeks, Andrea
    Morrison, David
    Alauzun, Johan G.
    Brook, Michael A.
    Jones, Lyndon
    Sheardown, Heather
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART A, 2012, 100A (08) : 1972 - 1982
  • [47] Attachment to and penetration of conventional and silicone hydrogel contact lenses by Fusarium solani and Ulocladium sp in vitro
    Ahearn, Donald G.
    Simmons, Robert B.
    Zhang, Shangtong
    Stulting, R. Doyle
    Crow, Sidney A.
    Schwam, Brian L.
    Pierce, George E.
    CORNEA, 2007, 26 (07) : 831 - 839
  • [48] Bacterial adhesion to worn silicone hydrogel contact lenses
    Santos, Livia
    Rodrigues, Diana
    Lira, Madalena
    Real Oliveira, M. Elisabete C. D.
    Oliveira, Rosario
    Yebra-Pimentel Vilar, Eva
    Azeredo, Joana
    OPTOMETRY AND VISION SCIENCE, 2008, 85 (07) : 520 - 525
  • [49] The Epidemiology of Microbial Keratitis With Silicone Hydrogel Contact Lenses
    Stapleton, Fiona
    Keay, Lisa
    Edwards, Katie
    Holden, Brien
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2013, 39 (01): : 79 - 85
  • [50] Randomized crossover trial of silicone hydrogel contact lenses
    Garcia-Montero, Maria
    Rico-del-Viejo, Laura
    Llorens-Quintana, Clara
    Lorente-Velazquez, Amalia
    Luis Hernandez-Verdejo, Jose
    Madrid-Costa, David
    CONTACT LENS & ANTERIOR EYE, 2019, 42 (05): : 475 - 481