Mucin balls with wear of conventional and silicone hydrogel contact lenses

被引:24
|
作者
Tan, J
Keay, L
Jalbert, I
Naduvilath, TJ
Sweeney, DF [1 ]
Holden, BA
机构
[1] Univ New S Wales, Cooperat Res Ctr Eye Res & Technol, Sch Optometry & Vis Sci, Sydney, NSW 2052, Australia
[2] Univ New S Wales, Cornea & Contact Lens Res Unit, Sch Optometry & Vis Sci, Sydney, NSW 2052, Australia
关键词
soft contact lens; high Dk; silicone hydrogel; mucin balls; microdeposits; lipid plugs;
D O I
10.1097/00006324-200304000-00006
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To compare the frequency of mucin balls in subjects wearing conventional and high-Dk silicone hydrogel lenses during 12 months of extended-wear and to determine whether mucin balls are associated with any lens or subject characteristics. Methods. This study used data from a clinical trial where subjects wore either conventional hydrogel (N = 69, 6-night extended-wear) or silicone hydrogel (N = 70, 30-night extended-wear) contact lenses for 12 months. The number of mucin balls and other physiological responses, lens fit and performance, and subjective patient responses to lens wear were rated at each scheduled visit. Results. Subjects in the silicone hydrogel group had significantly greater numbers of mucin balls compared with subjects in the conventional hydrogel group over time (p < 0.001), but there were no significant differences in the percentage of subjects with mucin balls between the two groups. Increasing lens wettability, back surface deposits, and time of lens wear were associated with higher numbers of mucin balls in the conventional hydrogel group (p < 0.05); steeper corneal curvature and increasing lens wettability, back surface deposits, and number of microcysts were associated with higher numbers of mucin balls in the silicone hydrogel group (p < 0.05). Conclusions. This study indicates that a subset of the population is predisposed to develop mucin balls irrespective of the soft contact lens type worn, but lens type influences the degree of mucin ball formation. The relationship between lens wettability, back surface deposits, and steeper corneal curvature with mucin balls supports the hypothesis that the mechanical interaction of a lens with the surface layer of the epithelium and the tear film in association with the blinking forces of the lid is involved in mucin ball formation.
引用
收藏
页码:291 / 297
页数:7
相关论文
共 50 条
  • [31] Contact Lens Lipid Spoliation of Hydrogel and Silicone Hydrogel Lenses
    Maissa, Cecile
    Guillon, Michel
    Cockshott, Nik
    Garofalo, Renee J.
    Lemp, Jessie M.
    Boclair, Joseph W.
    OPTOMETRY AND VISION SCIENCE, 2014, 91 (09) : 1071 - 1083
  • [32] Comparison of Silicone Hydrogel and Hydrogel Daily Disposable Contact Lenses
    Diec, Jennie
    Tilia, Daniel
    Thomas, Varghese
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2018, 44 : S167 - S172
  • [33] In Vitro Lipid Deposition on Hydrogel and Silicone Hydrogel Contact Lenses
    Pucker, Andrew D.
    Thangavelu, Mirunalni
    Nichols, Jason J.
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (12) : 6334 - 6340
  • [34] Comfort and adaptation to silicone hydrogel lenses for daily wear
    Dumbleton, Kathryn A.
    Woods, Craig A.
    Jones, Lyndon W.
    Fonn, Desmond
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2008, 34 (04): : 215 - 223
  • [35] Dynamic Contact Angle Analysis of Silicone Hydrogel Contact Lenses
    Read, Michael Leonard
    Morgan, Philip Bruce
    Kelly, Jeremiah Michael
    Maldonado-Codina, Carole
    JOURNAL OF BIOMATERIALS APPLICATIONS, 2011, 26 (01) : 85 - 99
  • [36] Influence of day and night wear on surface properties of silicone hydrogel contact lenses and bacterial adhesion
    Vermeltfoort, P
    Rustema-Abbing, M
    De Vries, J
    Bruinsma, M
    Busscher, HJ
    Van der Linden, ML
    Hooymans, JMM
    Van der Mei, HC
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2005, 46
  • [37] Objective and subjective responses in patients refitted to daily-wear silicone hydrogel contact lenses
    Dumbleton, Kathryn
    Keir, Nancy
    Moezzi, Amir
    Feng, Yunwei
    Jones, Lyndon
    Fonn, Desmond
    OPTOMETRY AND VISION SCIENCE, 2006, 83 (10) : 758 - 768
  • [38] Shape of the anterior surface of the cornea after extended wear of silicone hydrogel soft contact lenses
    Stachura, Joanna
    Mlyniuk, Patryk
    Bloch, Waldemar
    Jimenez-Villar, Alfonso
    Grulkowski, Ireneusz
    Kaluzny, Bartlomiej J.
    OPHTHALMIC AND PHYSIOLOGICAL OPTICS, 2021, 41 (04) : 683 - 690
  • [39] Risk Factors for Corneal Infiltrative Events during Continuous Wear of Silicone Hydrogel Contact Lenses
    Szczotka-Flynn, Loretta
    Lass, Jonathan H.
    Sethi, Ajay
    Debanne, Sara
    Benetz, Beth Ann
    Albright, Matthew
    Gillespie, Beth
    Kuo, Jana
    Jacobs, Michael R.
    Rimm, Alfred
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2010, 51 (11) : 5421 - 5430
  • [40] Risk Factors for Corneal Inflammatory and Mechanical Events with Extended Wear Silicone Hydrogel Contact Lenses
    Ozkan, Jerome
    Mandathara, Preeji
    Krishna, Pravin
    Sankaridurg, Padmaja
    Naduvilath, Thomas
    Willcox, Mark D. P.
    Holden, Brien
    OPTOMETRY AND VISION SCIENCE, 2010, 87 (11) : 847 - 853