Mucin balls with wear of conventional and silicone hydrogel contact lenses

被引:24
|
作者
Tan, J
Keay, L
Jalbert, I
Naduvilath, TJ
Sweeney, DF [1 ]
Holden, BA
机构
[1] Univ New S Wales, Cooperat Res Ctr Eye Res & Technol, Sch Optometry & Vis Sci, Sydney, NSW 2052, Australia
[2] Univ New S Wales, Cornea & Contact Lens Res Unit, Sch Optometry & Vis Sci, Sydney, NSW 2052, Australia
关键词
soft contact lens; high Dk; silicone hydrogel; mucin balls; microdeposits; lipid plugs;
D O I
10.1097/00006324-200304000-00006
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To compare the frequency of mucin balls in subjects wearing conventional and high-Dk silicone hydrogel lenses during 12 months of extended-wear and to determine whether mucin balls are associated with any lens or subject characteristics. Methods. This study used data from a clinical trial where subjects wore either conventional hydrogel (N = 69, 6-night extended-wear) or silicone hydrogel (N = 70, 30-night extended-wear) contact lenses for 12 months. The number of mucin balls and other physiological responses, lens fit and performance, and subjective patient responses to lens wear were rated at each scheduled visit. Results. Subjects in the silicone hydrogel group had significantly greater numbers of mucin balls compared with subjects in the conventional hydrogel group over time (p < 0.001), but there were no significant differences in the percentage of subjects with mucin balls between the two groups. Increasing lens wettability, back surface deposits, and time of lens wear were associated with higher numbers of mucin balls in the conventional hydrogel group (p < 0.05); steeper corneal curvature and increasing lens wettability, back surface deposits, and number of microcysts were associated with higher numbers of mucin balls in the silicone hydrogel group (p < 0.05). Conclusions. This study indicates that a subset of the population is predisposed to develop mucin balls irrespective of the soft contact lens type worn, but lens type influences the degree of mucin ball formation. The relationship between lens wettability, back surface deposits, and steeper corneal curvature with mucin balls supports the hypothesis that the mechanical interaction of a lens with the surface layer of the epithelium and the tear film in association with the blinking forces of the lid is involved in mucin ball formation.
引用
收藏
页码:291 / 297
页数:7
相关论文
共 50 条
  • [1] An evaluation of mucin balls associated with high-DK silicone-hydrogel contact lens wear
    Craig, JP
    Sherwin, T
    Grupcheva, CN
    McGhee, CNJ
    LACRIMAL GLAND, TEAR FILM, AND DRY EYE SYNDROMES 3: BASIC SCIENCE AND CLINICAL RELEVANCE, PTS A & B, 2002, 506 : 917 - 923
  • [2] Continuous wear silicone hydrogel contact lenses and microbial keratitis
    Whiting, MAN
    Raynor, MK
    Morgan, PB
    Galloway, P
    Tole, DM
    Tullo, A
    EYE, 2004, 18 (09) : 935 - 937
  • [3] Continuous wear silicone hydrogel contact lenses and microbial keratitis
    M A N Whiting
    M K Raynor
    P B Morgan
    P Galloway
    D M Tole
    A Tullo
    Eye, 2004, 18 : 935 - 937
  • [4] Changes in Ultraviolet Transmittance of Hydrogel and Silicone Hydrogel Contact Lenses Induced by Wear
    Shedden, Arthur
    Pall, Brian
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2015, 41 (01): : 64 - 64
  • [5] Microbial keratitis associated with extended wear of silicone hydrogel contact lenses
    Lim, L
    Loughnan, MS
    Sullivan, LJ
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2002, 86 (03) : 355 - 357
  • [6] Microbial keratitis associated with overnight wear of silicone hydrogel contact lenses
    Landers, John A.
    Crompton, John L.
    MEDICAL JOURNAL OF AUSTRALIA, 2006, 185 (03) : 177 - 178
  • [7] Infection immunology in silicone hydrogel contact lenses for continuous wear - A review
    Bialasiewicz, AA
    KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 2003, 220 (07) : 453 - 458
  • [8] Pseudomonas keratitis associated with daily wear of silicone hydrogel contact lenses
    Schornack, Muriel M.
    Faia, Lisa J.
    Griepentrog, Gregory J.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2008, 34 (02): : 124 - 128
  • [9] In Response: Changes in Ultraviolet Transmittance of Hydrogel and Silicone Hydrogel Contact Lenses Induced by Wear
    Uchechukwu, Osuagwu L.
    Ogbuehi, Kelechi C.
    Almubrad, Turki M.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2015, 41 (04): : 252 - 254
  • [10] Changes in Ultraviolet Transmittance of Hydrogel and Silicone-Hydrogel Contact Lenses Induced by Wear
    Osuagwu, Uchechukwu L.
    Ogbuehi, Kelechi C.
    AlMubrad, Turki M.
    EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2014, 40 (01): : 28 - 36