Hemodynamic effects of different fluid volumes for a fluid challenge in septic shock patients

被引:2
|
作者
Yang, Ting [1 ]
Weng, Li [1 ]
Jiang, Wei [1 ]
Li, Shan [1 ]
Du, Bin [1 ]
机构
[1] Chinese Acad Med Sci, Peking Union Med Coll Hosp, Peking Union Med Coll, Med Intens Care Unit, 1 Shuai Fu Yuan, Beijing 100730, Peoples R China
关键词
Cardiac output (CO); Fluid challenge (FC); Arterial load; Effective arterial elastance (Ea); Septic shock; INTENSIVE-CARE; ARTERIAL LOAD; RESPONSIVENESS; MANAGEMENT; SEPSIS;
D O I
10.1097/CM9.0000000000001919
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: It is still unclear what the minimal infusion volume is to effectively predict fluid responsiveness. This study was designed to explore the minimal infusion volume to effectively predict fluid responsiveness in septic shock patients. Hemodynamic effects of fluid administration on arterial load were observed and added values of effective arterial elastance (Ea) in fluid resuscitation were assessed. Methods: Intensive care unit septic shock patients with indwelling pulmonary artery catheter (PAC) received five sequential intravenous boluses of 100 mL 4% gelatin. Cardiac output (CO) was measured with PAC before and after each bolus. Fluid responsiveness was defined as an increase in CO >10% after 500 mL fluid infusion. Results: Forty-seven patients were included and 35 (74.5%) patients were fluid responders. CO increasing >5.2% after a 200 mL fluid challenge (FC) provided an improved detection of fluid responsiveness, with a specificity of 80.0% and a sensitivity of 91.7%. The area under the ROC curve (AUC) was 0.93 (95% CI: 0.84-1.00, P < 0.001). Fluid administration induced a decrease in Ea from 2.23 (1.46-2.78) mmHg/mL to 1.83 (1.34-2.44) mmHg/mL (P = 0.002), especially for fluid responders in whom arterial pressure did not increase. Notably, the baseline Ea was able to detect the fluid responsiveness with an AUC of 0.74 (95% CI: 0.59-0.86, P < 0.001), whereas Ea failed to predict the pressure response to FC with an AUC of 0.50 (95% CI: 0.33-0.67, P = 0.086). Conclusion: In septic shock patients, a minimal volume of 200 mL 4% gelatin could reliably detect fluid responders. Fluid administration reduced Ea even when CO increased. The loss of arterial load might be the reason for patients who increased their CO without pressure responsiveness. Moreover, a high level of Ea before FC was able to predict fluid responsiveness rather than to detect the pressure responsiveness.
引用
收藏
页码:672 / 680
页数:9
相关论文
共 50 条
  • [41] Fluid resuscitation with colloids of different molecular weight in septic shock
    Molnár, Z
    Mikor, A
    Leiner, T
    Szakmány, T
    INTENSIVE CARE MEDICINE, 2004, 30 (07) : 1356 - 1360
  • [42] Initial fluid resuscitation in patients with septic shock: Is fluid expansion achievement the real objective?
    Jouffroy, Romain
    Gueye, Papa
    AMERICAN JOURNAL OF EMERGENCY MEDICINE, 2022, 57 : 172 - 173
  • [43] Optimal central venous pressure in fluid challenge in severe sepsis and septic shock
    Dobrin, BN
    Soldati, G
    Van Nuffelen, M
    Vincent, JL
    CRITICAL CARE MEDICINE, 2005, 33 (12) : A166 - A166
  • [44] HEMODYNAMIC-RESPONSE TO FLUID REPLETION IN PATIENTS WITH SEPTIC SHOCK - EVIDENCE FOR EARLY DEPRESSION OF CARDIAC-PERFORMANCE
    RACKOW, EC
    KAUFMAN, BS
    FALK, JL
    ASTIZ, ME
    WEIL, MH
    CIRCULATORY SHOCK, 1987, 22 (01) : 11 - 22
  • [45] Fluid resuscitation in septic shock - Reply
    Singhi, S
    INDIAN PEDIATRICS, 2005, 42 (08) : 845 - 846
  • [46] Fluid resuscitation in early septic shock
    Mellis, Craig
    JOURNAL OF PAEDIATRICS AND CHILD HEALTH, 2019, 55 (10) : 1286 - 1287
  • [47] Septic shock and amniotic fluid embolism
    Guerry, M. J.
    Robriquet, L.
    Ducq, P.
    Boisson-Gaudin, C.
    Fourrier, F.
    MEDECINE ET MALADIES INFECTIEUSES, 2012, 42 (02): : 86 - 88
  • [48] Choice of fluid for resuscitation of septic shock
    Sparrow, A
    Hedderley, T
    Nadel, S
    EMERGENCY MEDICINE JOURNAL, 2002, 19 (02) : 114 - 116
  • [49] FLUID RESUSCITATION AND INOTROPES IN SEPTIC SHOCK
    Iramain, R.
    Kissoon, N.
    Ortiz, J.
    Jara, A.
    Bogado, N.
    Morinigo, R.
    PEDIATRIC CRITICAL CARE MEDICINE, 2022, 23 (11)
  • [50] Fluid responsiveness predicted by elevation of PEEP in patients with septic shock
    Wilkman, E.
    Kuitunen, A.
    Pettila, V.
    Varpula, M.
    ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2014, 58 (01) : 27 - 35