Hemodynamic effects of different fluid volumes for a fluid challenge in septic shock patients

被引:2
|
作者
Yang, Ting [1 ]
Weng, Li [1 ]
Jiang, Wei [1 ]
Li, Shan [1 ]
Du, Bin [1 ]
机构
[1] Chinese Acad Med Sci, Peking Union Med Coll Hosp, Peking Union Med Coll, Med Intens Care Unit, 1 Shuai Fu Yuan, Beijing 100730, Peoples R China
关键词
Cardiac output (CO); Fluid challenge (FC); Arterial load; Effective arterial elastance (Ea); Septic shock; INTENSIVE-CARE; ARTERIAL LOAD; RESPONSIVENESS; MANAGEMENT; SEPSIS;
D O I
10.1097/CM9.0000000000001919
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: It is still unclear what the minimal infusion volume is to effectively predict fluid responsiveness. This study was designed to explore the minimal infusion volume to effectively predict fluid responsiveness in septic shock patients. Hemodynamic effects of fluid administration on arterial load were observed and added values of effective arterial elastance (Ea) in fluid resuscitation were assessed. Methods: Intensive care unit septic shock patients with indwelling pulmonary artery catheter (PAC) received five sequential intravenous boluses of 100 mL 4% gelatin. Cardiac output (CO) was measured with PAC before and after each bolus. Fluid responsiveness was defined as an increase in CO >10% after 500 mL fluid infusion. Results: Forty-seven patients were included and 35 (74.5%) patients were fluid responders. CO increasing >5.2% after a 200 mL fluid challenge (FC) provided an improved detection of fluid responsiveness, with a specificity of 80.0% and a sensitivity of 91.7%. The area under the ROC curve (AUC) was 0.93 (95% CI: 0.84-1.00, P < 0.001). Fluid administration induced a decrease in Ea from 2.23 (1.46-2.78) mmHg/mL to 1.83 (1.34-2.44) mmHg/mL (P = 0.002), especially for fluid responders in whom arterial pressure did not increase. Notably, the baseline Ea was able to detect the fluid responsiveness with an AUC of 0.74 (95% CI: 0.59-0.86, P < 0.001), whereas Ea failed to predict the pressure response to FC with an AUC of 0.50 (95% CI: 0.33-0.67, P = 0.086). Conclusion: In septic shock patients, a minimal volume of 200 mL 4% gelatin could reliably detect fluid responders. Fluid administration reduced Ea even when CO increased. The loss of arterial load might be the reason for patients who increased their CO without pressure responsiveness. Moreover, a high level of Ea before FC was able to predict fluid responsiveness rather than to detect the pressure responsiveness.
引用
收藏
页码:672 / 680
页数:9
相关论文
共 50 条
  • [11] Effects of fluid administration on arterial load in septic shock patients
    Manuel Ignacio Monge García
    Pedro Guijo González
    Manuel Gracia Romero
    Anselmo Gil Cano
    Chris Oscier
    Andrew Rhodes
    Robert Michael Grounds
    Maurizio Cecconi
    Intensive Care Medicine, 2015, 41 : 1247 - 1255
  • [12] Effects of fluid administration on arterial load in septic shock patients
    Monge Garcia, Manuel Ignacio
    Guijo Gonzalez, Pedro
    Gracia Romero, Manuel
    Gil Cano, Anselmo
    Oscier, Chris
    Rhodes, Andrew
    Grounds, Robert Michael
    Cecconi, Maurizio
    INTENSIVE CARE MEDICINE, 2015, 41 (07) : 1247 - 1255
  • [13] Variability in the Hemodynamic Response to Fluid Bolus in Pediatric Septic Shock
    Ranjit, Suchitra
    Natraj, Rajeswari
    Kissoon, Niranjan
    Thiagarajan, Ravi R.
    Ramakrishnan, Balasubramaniam
    Monge Garcia, M. Ignacio
    PEDIATRIC CRITICAL CARE MEDICINE, 2021, 22 (08) : E448 - E458
  • [14] Hemodynamic support in fluid-refractory pediatric septic shock
    Ceneviva, G
    Paschall, JA
    Maffei, F
    Carcillo, JA
    PEDIATRICS, 1998, 102 (02) : art. no. - e19
  • [15] Renal hemodynamic monitoring-guided precision fluid therapy in patients with septic shock
    Li, Ying
    Xiao, Wenbiao
    Lin, Xiao
    MINERVA MEDICA, 2024,
  • [16] OPTIMUM LEFT HEART FILLING PRESSURE DURING FLUID CHALLENGE OF PATIENTS WITH SEPTIC SHOCK
    PACKMAN, MI
    RACKOW, EC
    CRITICAL CARE MEDICINE, 1981, 9 (03) : 234 - 234
  • [17] Optimizing Fluid Resuscitation and Preventing Fluid Overload in Patients with Septic Shock
    Ravi, Chandni
    Johnson, Daniel W.
    SEMINARS IN RESPIRATORY AND CRITICAL CARE MEDICINE, 2021, 42 (05) : 698 - 705
  • [18] EFFECTS OF FLUID RESUSCITATION WITH CRYSTALLOID AND ALBUMIN IN REFRACTORY SEPTIC SHOCK PATIENTS
    Shigle, Amanda
    Winter, Jessica
    Droege, Chris
    Ernst, Neil
    Foertsch, Madeline
    CRITICAL CARE MEDICINE, 2020, 48
  • [19] Changes in Radial Artery Pulse Pressure During a Fluid Challenge Cannot Assess Fluid Responsiveness in Patients With Septic Shock
    De la Puente-Diaz de Leon, Victor
    Jaramillo-Rocha, Valente de Jesus
    Teboul, Jean-Louis
    Garcia-Miranda, Sofia
    Martinez-Guerra, Bernardo A.
    Dominguez-Cherit, Guillermo
    JOURNAL OF INTENSIVE CARE MEDICINE, 2020, 35 (02) : 149 - 153
  • [20] Changes in B-type natriuretic peptide and related hemodynamic parameters following a fluid challenge in patients with severe sepsis or septic shock
    S Omar
    LR Mathivha
    A Ali
    Critical Care, 16 (Suppl 1):