Hemodynamic effects of different fluid volumes for a fluid challenge in septic shock patients

被引:2
|
作者
Yang, Ting [1 ]
Weng, Li [1 ]
Jiang, Wei [1 ]
Li, Shan [1 ]
Du, Bin [1 ]
机构
[1] Chinese Acad Med Sci, Peking Union Med Coll Hosp, Peking Union Med Coll, Med Intens Care Unit, 1 Shuai Fu Yuan, Beijing 100730, Peoples R China
关键词
Cardiac output (CO); Fluid challenge (FC); Arterial load; Effective arterial elastance (Ea); Septic shock; INTENSIVE-CARE; ARTERIAL LOAD; RESPONSIVENESS; MANAGEMENT; SEPSIS;
D O I
10.1097/CM9.0000000000001919
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: It is still unclear what the minimal infusion volume is to effectively predict fluid responsiveness. This study was designed to explore the minimal infusion volume to effectively predict fluid responsiveness in septic shock patients. Hemodynamic effects of fluid administration on arterial load were observed and added values of effective arterial elastance (Ea) in fluid resuscitation were assessed. Methods: Intensive care unit septic shock patients with indwelling pulmonary artery catheter (PAC) received five sequential intravenous boluses of 100 mL 4% gelatin. Cardiac output (CO) was measured with PAC before and after each bolus. Fluid responsiveness was defined as an increase in CO >10% after 500 mL fluid infusion. Results: Forty-seven patients were included and 35 (74.5%) patients were fluid responders. CO increasing >5.2% after a 200 mL fluid challenge (FC) provided an improved detection of fluid responsiveness, with a specificity of 80.0% and a sensitivity of 91.7%. The area under the ROC curve (AUC) was 0.93 (95% CI: 0.84-1.00, P < 0.001). Fluid administration induced a decrease in Ea from 2.23 (1.46-2.78) mmHg/mL to 1.83 (1.34-2.44) mmHg/mL (P = 0.002), especially for fluid responders in whom arterial pressure did not increase. Notably, the baseline Ea was able to detect the fluid responsiveness with an AUC of 0.74 (95% CI: 0.59-0.86, P < 0.001), whereas Ea failed to predict the pressure response to FC with an AUC of 0.50 (95% CI: 0.33-0.67, P = 0.086). Conclusion: In septic shock patients, a minimal volume of 200 mL 4% gelatin could reliably detect fluid responders. Fluid administration reduced Ea even when CO increased. The loss of arterial load might be the reason for patients who increased their CO without pressure responsiveness. Moreover, a high level of Ea before FC was able to predict fluid responsiveness rather than to detect the pressure responsiveness.
引用
收藏
页码:672 / 680
页数:9
相关论文
共 50 条
  • [1] Hemodynamic effects of different fluid volumes for a fluid challenge in septic shock patients
    Yang Ting
    Weng Li
    Jiang Wei
    Li Shan
    Du Bin
    中华医学杂志英文版, 2022, 135 (06) : 672 - 680
  • [2] Hemodynamic effects of different fluid volumes for a fluid challenge in septic shock patients (vol 135, pg 672, 2022)
    Yang, T.
    Weng, L.
    Jiang, W.
    Li, S.
    Du, B.
    CHINESE MEDICAL JOURNAL, 2022, 135 (08)
  • [3] Utility Of Central Venous Pressure And Shock Index In Predicting Hemodynamic Response To Fluid Challenge In Patients With Septic Shock
    Lanspa, M. J.
    Brown, S.
    Li, Y.
    Pittman, J. E.
    Jones, J.
    Grissom, C.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2011, 183
  • [4] Sublingual microcirculatory response to fluid challenge in septic shock patients
    M Losser
    V Cirillo
    C Barbanti
    D Payen
    Critical Care, 8 (Suppl 1):
  • [5] Systemic and regional hemodynamic effects of fluid resuscitation in experimental septic shock
    AG Garrido
    LF Poli de Figueiredo
    E Silva
    R Cruz
    FAB Auler
    MM Yada-Langui
    M Rocha e Silva
    Critical Care, 7 (Suppl 3):
  • [6] FLUID RESUSCITATION ON TIME TO HEMODYNAMIC STABILITY IN OBESE PATIENTS WITH SEPTIC SHOCK
    Kiracofe, Brittany
    Doepker, Bruce
    Riha, Heidi
    Wilkinson, Rachel
    Rozycki, Elizabeth
    Adkins, Eric
    Lehman, Amy
    Patel, Megan Van Berkel
    CRITICAL CARE MEDICINE, 2019, 47
  • [7] Dynamic Parameters Predict Hemodynamic Response To A Fluid Challenge In Non-Mechanically Ventilated Patients With Septic Shock
    Lanspa, M. J.
    Brown, S.
    Jones, J.
    Pittman, J. E.
    Grissom, C. K.
    AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2011, 183
  • [8] Study by transpulmonary thermodilution of fluid challenge response in patients with septic shock
    Puyoo, O
    Genestal, M
    Cougot, P
    Angles, O
    Charlet, JP
    INTENSIVE CARE MEDICINE, 2001, 27 : S148 - S148
  • [9] HEMODYNAMIC-EFFECTS OF ALBUMIN AND PENTASTARCH FLUID INFUSION IN MURINE SEPTIC SHOCK
    RACKOW, EC
    ASTIZ, ME
    MCKEE, D
    WEIL, MH
    CLINICAL RESEARCH, 1987, 35 (03): : A316 - A316
  • [10] Assessment of fluid resuscitation on time to hemodynamic stability in obese patients with septic shock
    Kiracofe-Hoyte, Brittany R.
    Doepker, Bruce A.
    Riha, Heidi M.
    Wilkinson, Rachel
    Rozycki, Elizabeth
    Adkins, Eric
    Lehman, Amy
    Van Berkel, Megan A.
    JOURNAL OF CRITICAL CARE, 2021, 63 : 196 - 201