Non-Contact Infrared-Depth Camera-Based Method for Respiratory Rhythm Measurement While Driving

被引:10
|
作者
Mateu-Mateus, Marc [1 ]
Guede-Fernandez, Federico [1 ]
Garcia-Gonzalez, Miguel A. [1 ]
Ramos-Castro, Juan [1 ]
Fernandez-Chimeno, Mireya [1 ]
机构
[1] Univ Politecn Cataluna, Dept Elect Engn, Barcelona 08034, Spain
关键词
Cameras; Feeds; Rhythm; Face; Thorax; Optical imaging; Real-time systems; Non-contact; respiration; IR; camera-based; point-cloud; computer vision; SIGNAL;
D O I
10.1109/ACCESS.2019.2947759
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This work proposes a new non-contact method based on Infrared and Depth cameras to measure respiratory rhythm in real-life situations. The proposed algorithm consists on using both video feeds to track the movements of the subject in real-time, compute the location of the face and calculate the most suitable ROI to extract the respiratory signal in adult population. 20 subjects were measured while driving in a car simulator with no constraints other than the simulator itself. The algorithm has been validated using a commercial thorax plethysmography system. An opportunistic approach has been used to obtain pieces from the tests for each subject, thus making a more realistic approach to the real-life situations where the signal is likely to contain errors. The breath-to-breath respiratory signal and the instantaneous frequency from both methods has been computed from each piece to characterise the error between the proposed method and the reference system. The results show a high correlation between the measured rhythm from the reference method and the proposed method, with relatively low error results and good sensitivity in cycle detection and low errors for the instantaneous frequency between methods. The error results have also been compared with the ones obtained in previous studies showing a good agreement between the obtained results and the ones presented in the previous studies. No relationship between the length of the pieces and the error has been found either for the respiratory cycle signal or the instantaneous frequency signal. The proposed algorithm can be used to measure respiratory rhythm in unconstrained conditions and with opportunistic measurements, thus making it suitable to perform in real-life situations while driving. Further studies taking into account vibrations or light changing conditions are needed to confirm that the proposed method performs with the same accuracy with these constraints.
引用
收藏
页码:152522 / 152532
页数:11
相关论文
共 50 条
  • [31] Neonatal non-contact respiratory monitoring based on real-time infrared thermography
    Abbas, Abbas K.
    Heimann, Konrad
    Jergus, Katrin
    Orlikowsky, Thorsten
    Leonhardt, Steffen
    BIOMEDICAL ENGINEERING ONLINE, 2011, 10
  • [32] Neonatal non-contact respiratory monitoring based on real-time infrared thermography
    Abbas K Abbas
    Konrad Heimann
    Katrin Jergus
    Thorsten Orlikowsky
    Steffen Leonhardt
    BioMedical Engineering OnLine, 10
  • [33] Non-Contact Respiration Measurement Method Based on RGB Camera Using 1D Convolutional Neural Networks
    Hwang, Hyeon-Sang
    Lee, Eui-Chul
    SENSORS, 2021, 21 (10)
  • [34] Vision-based automatic detection method for non-contact respiratory rate
    Liu J.
    Liu H.
    Jia X.
    Guo S.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2019, 40 (02): : 51 - 58
  • [35] Non-Contact Cardio-Pulmonary Resuscitation Compression Action Quality Monitoring Based on Depth Camera
    Geng, Fanglin
    Zhang, Hao
    Yao, Yicheng
    Xia, Pan
    Wang, Peng
    Chen, Xianxiang
    Li, Zhenfeng
    Du, Lidong
    Fang, Zhen
    2023 IEEE 19TH INTERNATIONAL CONFERENCE ON BODY SENSOR NETWORKS, BSN, 2023,
  • [36] Application of non-contact strain measurement based on CCD camera in PMMA material constitutive model
    Qian, Xiaohui
    Ma, Xiaoyan
    Heng, Yuekun
    He, Wei
    Tang, Hongqiang
    Hou, Shaojing
    Pei, Yatian
    MATERIALS RESEARCH EXPRESS, 2021, 8 (09)
  • [37] Non-contact 3D measurement method for evaluating thoracoabdominal motion in respiratory assessment
    Yasukawa, Makoto
    Noyori, Shuhei S.
    Ibara, Takuya
    Fujita, Koji
    Nimura, Akimoto
    2022 61ST ANNUAL CONFERENCE OF THE SOCIETY OF INSTRUMENT AND CONTROL ENGINEERS (SICE), 2022, : 815 - 820
  • [38] Non-Contact Video-Based Assessment of the Respiratory Function Using a RGB-D Camera
    Valenzuela, Andrea
    Sibuet, Nicolas
    Hornero, Gemma
    Casas, Oscar
    SENSORS, 2021, 21 (16)
  • [39] The infrared image based non-contact monitoring of respiratory waveform through deep Kalman filter
    Sun, Hao
    Huang, Zhipei
    Tong, Yonggang
    Shan, Guangcun
    Dai, Xuewu
    Qin, Fei
    2024 IEEE INTERNATIONAL SYMPOSIUM ON MEDICAL MEASUREMENTS AND APPLICATIONS, MEMEA 2024, 2024,
  • [40] Camera-Based, Non-Contact, Vital-Signs Monitoring Technology May Provide a Way for the Early Prevention of SIDS in Infants
    Zhao, Fang
    Li, Meng
    Jiang, Zhongyi
    Tsien, Joe Z.
    Lu, Zhaohui
    FRONTIERS IN NEUROLOGY, 2016, 7