Non-Contact Infrared-Depth Camera-Based Method for Respiratory Rhythm Measurement While Driving

被引:10
|
作者
Mateu-Mateus, Marc [1 ]
Guede-Fernandez, Federico [1 ]
Garcia-Gonzalez, Miguel A. [1 ]
Ramos-Castro, Juan [1 ]
Fernandez-Chimeno, Mireya [1 ]
机构
[1] Univ Politecn Cataluna, Dept Elect Engn, Barcelona 08034, Spain
关键词
Cameras; Feeds; Rhythm; Face; Thorax; Optical imaging; Real-time systems; Non-contact; respiration; IR; camera-based; point-cloud; computer vision; SIGNAL;
D O I
10.1109/ACCESS.2019.2947759
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
This work proposes a new non-contact method based on Infrared and Depth cameras to measure respiratory rhythm in real-life situations. The proposed algorithm consists on using both video feeds to track the movements of the subject in real-time, compute the location of the face and calculate the most suitable ROI to extract the respiratory signal in adult population. 20 subjects were measured while driving in a car simulator with no constraints other than the simulator itself. The algorithm has been validated using a commercial thorax plethysmography system. An opportunistic approach has been used to obtain pieces from the tests for each subject, thus making a more realistic approach to the real-life situations where the signal is likely to contain errors. The breath-to-breath respiratory signal and the instantaneous frequency from both methods has been computed from each piece to characterise the error between the proposed method and the reference system. The results show a high correlation between the measured rhythm from the reference method and the proposed method, with relatively low error results and good sensitivity in cycle detection and low errors for the instantaneous frequency between methods. The error results have also been compared with the ones obtained in previous studies showing a good agreement between the obtained results and the ones presented in the previous studies. No relationship between the length of the pieces and the error has been found either for the respiratory cycle signal or the instantaneous frequency signal. The proposed algorithm can be used to measure respiratory rhythm in unconstrained conditions and with opportunistic measurements, thus making it suitable to perform in real-life situations while driving. Further studies taking into account vibrations or light changing conditions are needed to confirm that the proposed method performs with the same accuracy with these constraints.
引用
收藏
页码:152522 / 152532
页数:11
相关论文
共 50 条
  • [21] Non-contact Measurement of Respiratory and Heart Rates Using a CMOS Camera-equipped Infrared Camera for Prompt Infection Screening at Airport Quarantine Stations
    Nakayama, Yosuke
    Sun, Guanghao
    Abe, Shigeto
    Matsui, Takemi
    2015 IEEE INTERNATIONAL CONFERENCE ON COMPUTATIONAL INTELLIGENCE AND VIRTUAL ENVIRONMENTS FOR MEASUREMENT SYSTEMS AND APPLICATIONS (CIVEMSA), 2015, : 27 - 30
  • [22] Non-contact sensing of neonatal pulse rate using camera-based imaging: a clinical feasibility study
    Paul, M.
    Karthik, S.
    Joseph, J.
    Sivaprakasam, M.
    Kumutha, J.
    Leonhardt, S.
    Antink, C. Hoog
    PHYSIOLOGICAL MEASUREMENT, 2020, 41 (02)
  • [23] Non-contact measurement method of respiratory movement under pedal stroke motion
    Aoki, Hirooki
    Ichimura, Shiro
    Kiyooka, Satoru
    Koshiji, Kohji
    2007 ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-16, 2007, : 374 - +
  • [24] Measurement of drag coefficients of non-spherical particles with a camera-based method
    Krueger, B.
    Wirtz, S.
    Scherer, V.
    POWDER TECHNOLOGY, 2015, 278 : 157 - 170
  • [25] A non-contact gear measurement method based on laser vision
    Song L.-M.
    Qin M.-C.
    Li Z.-Y.
    Yang Y.-G.
    Li D.-P.
    Song, L.-M. (lilymay1976@126.com), 1600, Springer Verlag (10): : 237 - 240
  • [26] A non-contact gear measurement method based on laser vision
    宋丽梅
    覃名翠
    李宗艳
    杨燕罡
    李大鹏
    Optoelectronics Letters, 2014, 10 (03) : 237 - 240
  • [27] Respiratory signal and human stress: non-contact detection of stress with a low-cost depth sensing camera
    Yuhao Shan
    Shigang Li
    Tong Chen
    International Journal of Machine Learning and Cybernetics, 2020, 11 : 1825 - 1837
  • [28] Respiratory signal and human stress: non-contact detection of stress with a low-cost depth sensing camera
    Shan, Yuhao
    Li, Shigang
    Chen, Tong
    INTERNATIONAL JOURNAL OF MACHINE LEARNING AND CYBERNETICS, 2020, 11 (08) : 1825 - 1837
  • [29] Non-contact skin moisture measurement based on near-infrared spectroscopy
    Arimoto, H
    Egawa, M
    APPLIED SPECTROSCOPY, 2004, 58 (12) : 1439 - 1446
  • [30] A non-contact ECG measurement method based on capacitance coupling electrodes
    Wang Y.
    Li J.
    Xu Z.
    Tian X.
    Li C.
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2022, 43 (02): : 138 - 147