Application of low-dose CT combined with model-based iterative reconstruction algorithm in oncologic patients during follow-up: dose reduction and image quality

被引:8
|
作者
Ippolito, Davide [1 ]
Maino, Cesare [1 ]
Pecorelli, Anna [1 ]
Salemi, Ilaria [1 ]
Gandola, Davide [1 ]
Riva, Luca [1 ]
Franzesi, Cammillo Talei [1 ]
Sironi, Sandro [2 ]
机构
[1] San Gerardo Hosp, Dept Diagnost Radiol, Monza, MB, Italy
[2] H Papa Giovanni XXIII, Dept Diagnost Radiol, Bergamo, BG, Italy
来源
BRITISH JOURNAL OF RADIOLOGY | 2021年 / 94卷 / 1124期
关键词
FILTERED BACK-PROJECTION; COMPUTED-TOMOGRAPHY; SCANS; CHEST; RISK;
D O I
10.1259/bjr.20201223
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To compare image quality and radiation dose of CT images reconstructed with model-based iterative reconstruction (MBIR) and hybrid-iterative (HIR) algorithm in oncologic patients. Methods: 125 oncologic patients underwent both contrast-enhanced low- (100 kV), and standard (120 kV) dose CT, were enrolled. Image quality was assessed by using a 4-point Likert scale. CT attenuation values, expressed in Hounsfield unit (HU), were recorded within a regions of interest (ROI) of liver, spleen, paraspinal muscle, aortic lumen, and subcutaneous fat tissue. Image noise, expressed as standard deviation (SD), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were calculated. Radiation dose were analyzed. Paired Student's t-test was used to compare all continuous variables. Results: The overall median score assessed as image quality for CT images with the MBIR algorithm was significantly higher in comparison with HIR [4 (range 3-4) vs 3 (3-4), p = 0.017]. CT attenuation values and SD were significantly higher and lower, respectively, in all anatomic districts in images reconstructed with MBIR in comparison with HIR ones (all p < 0.001). SNR and CNR values were higher in CT images reconstructed with MBIR, reaching a significant difference in all districts (all p < 0.001). Radiation dose were significantly lower in the MBIR group compared with the HIR group (p < 0.001). Conclusions: MBIR combined with low-kV setting allows an important dose reduction in whole-body CT imaging, reaching a better image quality both qualitatively and quantitatively. Advances in knowledge: MBIR with low-dose approach allows a reduction of dose exposure, maintaining high image quality, especially in patients which deserve a longlasting follow-up.
引用
收藏
页数:9
相关论文
共 50 条
  • [31] Improved image quality of low-dose CT combining with iterative model reconstruction algorithm for response assessment in patients after treatment of malignant tumor
    Xin, Xiaoyan
    Shen, Jingtao
    Yang, Shangwen
    Liu, Song
    Hu, Anning
    Zhu, Bin
    Jiang, Yan
    Li, Baoxin
    Zhang, Bing
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2018, 8 (07) : 648 - 657
  • [32] Intra-patient comparison of reduced-dose model-based iterative reconstruction with standard-dose adaptive statistical iterative reconstruction in the CT diagnosis and follow-up of urolithiasis
    Tenant, Sean
    Pang, Chun Lap
    Dissanayake, Prageeth
    Vardhanabhuti, Varut
    Stuckey, Colin
    Gutteridge, Catherine
    Hyde, Christopher
    Roobottom, Carl
    EUROPEAN RADIOLOGY, 2017, 27 (10) : 4163 - 4172
  • [33] Intra-patient comparison of reduced-dose model-based iterative reconstruction with standard-dose adaptive statistical iterative reconstruction in the CT diagnosis and follow-up of urolithiasis
    Sean Tenant
    Chun Lap Pang
    Prageeth Dissanayake
    Varut Vardhanabhuti
    Colin Stuckey
    Catherine Gutteridge
    Christopher Hyde
    Carl Roobottom
    European Radiology, 2017, 27 : 4163 - 4172
  • [34] Reducing the radiation dose for low-dose CT of the paranasal sinuses using iterative reconstruction: Feasibility and image quality
    Bulla, Stefan
    Blanke, Philipp
    Hassepass, Frederike
    Krauss, Tobias
    Winterer, Jan Thorsten
    Breunig, Christine
    Langer, Mathias
    Pache, Gregor
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (09) : 2246 - 2250
  • [35] Sinogram-Affirmed Iterative Reconstruction of Low-Dose Chest CT: Effect on Image Quality and Radiation Dose
    Kalra, Mannudeep K.
    Woisetschlaeger, Mischa
    Dahlstroem, Nils
    Singh, Sarabjeet
    Digumarthy, Subbarao
    Do, Synho
    Pien, Homer
    Quick, Petter
    Schmidt, Bernhard
    Sedlmair, Martin
    Shepard, Jo-Anne O.
    Persson, Anders
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2013, 201 (02) : W235 - W244
  • [36] Improving image quality with model-based iterative reconstruction at quarter of nominal dose in upper abdominal CT
    Zhang, Xirong
    Chen, Jing
    Yu, Nan
    Ren, Zhanli
    Tian, Qian
    Tian, Xin
    He, Taiping
    Guo, Changyi
    BRITISH JOURNAL OF RADIOLOGY, 2018, 92 (1093):
  • [37] Model-based Iterative Reconstruction: Effect on Patient Radiation Dose and Image Quality in Pediatric Body CT
    Smith, Ethan A.
    Dillman, Jonathan R.
    Goodsitt, Mitchell M.
    Christodoulou, Emmanuel G.
    Keshavarzi, Nahid
    Strouse, Peter J.
    RADIOLOGY, 2014, 270 (02) : 526 - 534
  • [38] Low-dose CT imaging of the acute abdomen using model-based iterative reconstruction: a prospective study
    Fiachra Moloney
    Karl James
    Maria Twomey
    David Ryan
    Tyler M. Grey
    Amber Downes
    Richard G. Kavanagh
    Niamh Moore
    Mary Jane Murphy
    Jackie Bye
    Brian W. Carey
    Sean E. McSweeney
    Conor Deasy
    Emmett Andrews
    Fergus Shanahan
    Michael M. Maher
    Owen J. O’Connor
    Emergency Radiology, 2019, 26 : 169 - 177
  • [39] Low-dose CT imaging of the acute abdomen using model-based iterative reconstruction: a prospective study
    Moloney, Fiachra
    James, Karl
    Twomey, Maria
    Ryan, David
    Grey, Tyler M.
    Downes, Amber
    Kavanagh, Richard G.
    Moore, Niamh
    Murphy, Mary Jane
    Bye, Jackie
    Carey, Brian W.
    McSweeney, Sean E.
    Deasy, Conor
    Andrews, Emmett
    Shanahan, Fergus
    Maher, Michael M.
    O'Connor, Owen J.
    EMERGENCY RADIOLOGY, 2019, 26 (02) : 169 - 177
  • [40] Evaluation of an Iterative model-based reconstruction of pediatric abdominal CT with regard to image quality and radiation dose
    Aurumskjold, Marie-Louise
    Soderberg, Marcus
    Stalhammar, Fredrik
    von Steyern, Kristina Vult
    Tingberg, Anders
    Ydstrom, Kristina
    ACTA RADIOLOGICA, 2018, 59 (06) : 740 - 747