Application of low-dose CT combined with model-based iterative reconstruction algorithm in oncologic patients during follow-up: dose reduction and image quality

被引:8
|
作者
Ippolito, Davide [1 ]
Maino, Cesare [1 ]
Pecorelli, Anna [1 ]
Salemi, Ilaria [1 ]
Gandola, Davide [1 ]
Riva, Luca [1 ]
Franzesi, Cammillo Talei [1 ]
Sironi, Sandro [2 ]
机构
[1] San Gerardo Hosp, Dept Diagnost Radiol, Monza, MB, Italy
[2] H Papa Giovanni XXIII, Dept Diagnost Radiol, Bergamo, BG, Italy
来源
BRITISH JOURNAL OF RADIOLOGY | 2021年 / 94卷 / 1124期
关键词
FILTERED BACK-PROJECTION; COMPUTED-TOMOGRAPHY; SCANS; CHEST; RISK;
D O I
10.1259/bjr.20201223
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives: To compare image quality and radiation dose of CT images reconstructed with model-based iterative reconstruction (MBIR) and hybrid-iterative (HIR) algorithm in oncologic patients. Methods: 125 oncologic patients underwent both contrast-enhanced low- (100 kV), and standard (120 kV) dose CT, were enrolled. Image quality was assessed by using a 4-point Likert scale. CT attenuation values, expressed in Hounsfield unit (HU), were recorded within a regions of interest (ROI) of liver, spleen, paraspinal muscle, aortic lumen, and subcutaneous fat tissue. Image noise, expressed as standard deviation (SD), signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR) were calculated. Radiation dose were analyzed. Paired Student's t-test was used to compare all continuous variables. Results: The overall median score assessed as image quality for CT images with the MBIR algorithm was significantly higher in comparison with HIR [4 (range 3-4) vs 3 (3-4), p = 0.017]. CT attenuation values and SD were significantly higher and lower, respectively, in all anatomic districts in images reconstructed with MBIR in comparison with HIR ones (all p < 0.001). SNR and CNR values were higher in CT images reconstructed with MBIR, reaching a significant difference in all districts (all p < 0.001). Radiation dose were significantly lower in the MBIR group compared with the HIR group (p < 0.001). Conclusions: MBIR combined with low-kV setting allows an important dose reduction in whole-body CT imaging, reaching a better image quality both qualitatively and quantitatively. Advances in knowledge: MBIR with low-dose approach allows a reduction of dose exposure, maintaining high image quality, especially in patients which deserve a longlasting follow-up.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Investigation of iterative image reconstruction in low-dose breast CT
    Bian, Junguo
    Yang, Kai
    Boone, John M.
    Han, Xiao
    Sidky, Emil Y.
    Pan, Xiaochuan
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (11): : 2659 - 2685
  • [22] Forward-Projected Model-Based Iterative Reconstruction in Screening Low-Dose Chest CT: Comparison With Adaptive Iterative Dose Reduction 3D
    Hassani, Cameron
    Ronco, Anthony
    Prosper, Ashley E.
    Dissanayake, Sumudu
    Cen, Steven Y.
    Lee, Christopher
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 211 (03) : 548 - 556
  • [23] Image Quality and Dose Reduction Evaluation of a New CT Iterative Reconstruction Algorithm Using Model Observers
    Tseng, H.
    Fan, J.
    Kupinski, M.
    Sainath, P.
    Hsieh, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [24] Assessment of a Model-Based, Iterative Reconstruction Algorithm (MBIR) Regarding Image Quality and Dose Reduction in Liver Computed Tomography
    Chang, Won
    Lee, Jeong Min
    Lee, Kyunghee
    Yoon, Jeong Hee
    Yu, Mi Hye
    Han, Joon Koo
    Choi, Byung Ihn
    INVESTIGATIVE RADIOLOGY, 2013, 48 (08) : 598 - 606
  • [25] Reduction of CT Exposure for Low-Dose CT Imaging by Iterative CT Reconstruction
    Grosser, O. S.
    Czuczwara, D.
    Wissel, H.
    Laatz, K.
    Ulrich, G.
    Furth, C.
    Ruf, J.
    Amthauer, H.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2012, 39 : S501 - S501
  • [26] Effects of Model-Based Iterative Reconstruction on Image Quality for Low-Dose Computed Tomographic Angiography of the Thoracic Aorta in a Swine Model
    Caywood, Devin
    Paxton, Ben
    Boll, Daniel
    Nelson, Rendon
    Kim, Charles
    Lowry, Carolyn
    Seaman, Danielle
    Roos, Justus E.
    Hurwitz, Lynne M.
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2015, 39 (02) : 196 - 201
  • [27] Low-dose CT of the thorax in cancer follow-up
    Yamada, T
    Ono, S
    Tsuboi, M
    Saito, H
    Sato, A
    Matsuhashi, T
    Ishibashi, T
    Takahashi, S
    EUROPEAN JOURNAL OF RADIOLOGY, 2004, 51 (02) : 169 - 174
  • [28] Image quality improvement using model-based iterative reconstruction in low dose chest CT for children with necrotizing pneumonia
    Sun, Jihang
    Yu, Tong
    Liu, Jinrong
    Duan, Xiaomin
    Hu, Di
    Liu, Yong
    Peng, Yun
    BMC MEDICAL IMAGING, 2017, 17
  • [29] Low-Dose CT of the Patients with 80kV Coronary Angiography Bypass Grafts Using Iterative Model Reconstruction: Evaluation of Image Quality and Radiation Dose Reduction
    Luo, C. C.
    Li, T.
    Yang, L.
    Huang, Z. L.
    Li, X. P.
    Liu, B.
    Yang, T.
    Qi, Y. Q.
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2019, 67 : S682 - S682
  • [30] Image quality improvement using model-based iterative reconstruction in low dose chest CT for children with necrotizing pneumonia
    Jihang Sun
    Tong Yu
    Jinrong Liu
    Xiaomin Duan
    Di Hu
    Yong liu
    Yun Peng
    BMC Medical Imaging, 17