New thermal neutron prompt γ-ray activation analysis instrument at the National Institute of Standards and Technology Center for Neutron Research

被引:26
|
作者
Mackey, EA
Anderson, DL
Liposky, PJ
Lindstrom, RM
Chen-Mayer, H
Lamaze, GP
机构
[1] Natl Inst Stand & Technol, Div Analyt Chem, Gaithersburg, MD 20899 USA
[2] US FDA, Elemental Res Branch, College Pk, MD 20740 USA
[3] Natl Inst Stand & Technol, Ctr Neutron Res, Gaithersburg, MD 20899 USA
关键词
gamma-ray spectrometry; neutron beam; neutron capture; prompt gamma activation analysis; prompt gamma-rays;
D O I
10.1016/j.nimb.2004.05.038
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new thermal neutron prompt gamma-ray activation analysis (PGAA) instrument was designed and built to replace the original PGAA system at the NIST Center for Neutron Research. By placing a sapphire filter in the neutron beam shutter assembly, the fast neutron fluence rate was reduced by a factor of 5 and low-energy (50-200 keV) gamma-ray intensities were reduced by factors of 5-10. The thermal neutron fluence rate was reduced by only a factor of 1.13. A new external beam tube, sample chamber, beam stop, and support structure were built and a new detection system installed. The new beam tube is made of two cylindrical aluminum sections lined with a lithiated polymer. Both sections are kept under vacuum to reduce the number of neutrons scattered by air into the beam tube walls. The sample chamber is also fabricated from aluminum and lined with lithiated polymer, and may be evacuated to minimize the number of neutrons scattered and absorbed by air. The beam tube and sample chamber assembly is suspended from the aluminum support structure. The detection system consists of a 40% efficient (relative) germanium detector (resolution 2.0 at 1332.5 keV) and a bismuth germanate Compton suppressor. The detection system is shielded by lead, surrounded by borated and lithiated polyethylene, and placed on a table attached to the support structure. The new, more compact beam stop is welded to the support structure. Capture gamma-ray photopeaks from H, B, C, N, Na, Al, Fe, Ge, I and Pb in the background spectrum were either of lower intensity or eliminated with the new PGAA instrument. The more efficient detection system, positioned closer to the sample, yielded element sensitivity increases of 5-50%. Limits of detection have been greatly reduced compared with those of the original instrument due to reduced Compton and scattered gamma-ray backgrounds (especially in the low-energy region), increased sensitivities, and reduction of background gamma-ray photopeak intensities. Published by Elsevier B.V.
引用
收藏
页码:426 / 440
页数:15
相关论文
共 50 条
  • [41] Analytical capability of an explosives detection by a prompt gamma-ray neutron activation analysis
    Im, Hee-Jung
    Cho, Hyun-Je
    Song, Byoung Chul
    Park, Yong Joon
    Chung, Yong-Sam
    Kim, Won-Ho
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 566 (02): : 442 - 447
  • [42] Cold neutron prompt gamma-ray activation analysis at NIST — Recent developments
    R. L. Paul
    R. M. Lindstrom
    A. E. Heald
    Journal of Radioanalytical and Nuclear Chemistry, 1997, 215 : 63 - 68
  • [43] Determination of boron in materials by cold neutron prompt gamma-ray activation analysis
    Paul, RL
    ANALYST, 2005, 130 (01) : 99 - 103
  • [44] Measurement of talc in flour by the prompt-gamma ray neutron activation analysis method
    Xu, Xu
    Lu, Jingbin
    Chang, Yi
    Tang, Wanyue
    Sun, Yuanming
    Zhao, Long
    Liu, Jiaxi
    Li, Chengqian
    Li, Xiaoyi
    Zheng, Renzhou
    Wang, Yu
    APPLIED RADIATION AND ISOTOPES, 2021, 178
  • [45] Cold neutron prompt gamma-ray activation analysis at NIST - Recent developments
    Paul, RL
    Lindstrom, RM
    Heald, AE
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1997, 215 (01) : 63 - 68
  • [46] Prompt gamma-ray analysis using cold and thermal guided neutron beams
    Yonezawa, C.
    Magara, M.
    Sawahata, H.
    Hoshi, M.
    Ito, Y.
    Tachikawa, E.
    Journal of Radioanalytical and Nuclear Chemistry, 1995, 193 (01): : 171 - 178
  • [47] DETERMINATION OF SILICON IN NATIONAL-INSTITUTE-OF-STANDARDS-AND-TECHNOLOGY BIOLOGICAL STANDARD REFERENCE MATERIALS BY INSTRUMENTAL EPITHERMAL NEUTRON-ACTIVATION AND X-RAY-FLUORESCENCE SPECTROMETRY
    GLADNEY, ES
    NEIFERT, PE
    BOWER, NW
    ANALYTICAL CHEMISTRY, 1989, 61 (17) : 1834 - 1836
  • [48] Improvements in food analysis by thermal neutron capture prompt gamma-ray spectrometry
    D. L. Anderson
    E. A. Mackey
    Journal of Radioanalytical and Nuclear Chemistry, 2005, 263 : 683 - 689
  • [49] PROMPT GAMMA-RAY ANALYSIS USING COLD AND THERMAL GUIDED NEUTRON BEAMS
    YONEZAWA, C
    MAGARA, M
    SAWAHATA, H
    HOSHI, M
    ITO, Y
    TACHIKAWA, E
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1995, 193 (01): : 171 - 178
  • [50] Improvements in food analysis by thermal neutron capture prompt gamma-ray spectrometry
    Anderson, DL
    Mackey, EA
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2005, 263 (03) : 683 - 689