New thermal neutron prompt γ-ray activation analysis instrument at the National Institute of Standards and Technology Center for Neutron Research

被引:26
|
作者
Mackey, EA
Anderson, DL
Liposky, PJ
Lindstrom, RM
Chen-Mayer, H
Lamaze, GP
机构
[1] Natl Inst Stand & Technol, Div Analyt Chem, Gaithersburg, MD 20899 USA
[2] US FDA, Elemental Res Branch, College Pk, MD 20740 USA
[3] Natl Inst Stand & Technol, Ctr Neutron Res, Gaithersburg, MD 20899 USA
关键词
gamma-ray spectrometry; neutron beam; neutron capture; prompt gamma activation analysis; prompt gamma-rays;
D O I
10.1016/j.nimb.2004.05.038
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new thermal neutron prompt gamma-ray activation analysis (PGAA) instrument was designed and built to replace the original PGAA system at the NIST Center for Neutron Research. By placing a sapphire filter in the neutron beam shutter assembly, the fast neutron fluence rate was reduced by a factor of 5 and low-energy (50-200 keV) gamma-ray intensities were reduced by factors of 5-10. The thermal neutron fluence rate was reduced by only a factor of 1.13. A new external beam tube, sample chamber, beam stop, and support structure were built and a new detection system installed. The new beam tube is made of two cylindrical aluminum sections lined with a lithiated polymer. Both sections are kept under vacuum to reduce the number of neutrons scattered by air into the beam tube walls. The sample chamber is also fabricated from aluminum and lined with lithiated polymer, and may be evacuated to minimize the number of neutrons scattered and absorbed by air. The beam tube and sample chamber assembly is suspended from the aluminum support structure. The detection system consists of a 40% efficient (relative) germanium detector (resolution 2.0 at 1332.5 keV) and a bismuth germanate Compton suppressor. The detection system is shielded by lead, surrounded by borated and lithiated polyethylene, and placed on a table attached to the support structure. The new, more compact beam stop is welded to the support structure. Capture gamma-ray photopeaks from H, B, C, N, Na, Al, Fe, Ge, I and Pb in the background spectrum were either of lower intensity or eliminated with the new PGAA instrument. The more efficient detection system, positioned closer to the sample, yielded element sensitivity increases of 5-50%. Limits of detection have been greatly reduced compared with those of the original instrument due to reduced Compton and scattered gamma-ray backgrounds (especially in the low-energy region), increased sensitivities, and reduction of background gamma-ray photopeak intensities. Published by Elsevier B.V.
引用
收藏
页码:426 / 440
页数:15
相关论文
共 50 条
  • [31] PROMPT GAMMA-RAY NEUTRON-ACTIVATION ANALYSIS OF RIVER SEDIMENTS
    SPYCHALA, M
    MICHAELIS, W
    FANGER, HU
    NUCLEAR GEOPHYSICS, 1987, 1 (04): : 309 - 317
  • [32] Development of a new deuterium-deuterium (D-D) neutron generator for prompt gamma-ray neutron activation analysis
    Bergaoui, K.
    Reguigui, N.
    Gary, C. K.
    Brown, C.
    Cremer, J. T.
    Vainionpaa, J. H.
    Piestrup, M. A.
    APPLIED RADIATION AND ISOTOPES, 2014, 94 : 319 - 327
  • [33] Characterization of hydrogen in concrete by cold neutron prompt gamma-ray activation analysis and neutron incoherent scattering
    Paul, RL
    Chen-Mayer, HH
    Lindstrom, RM
    Blaauw, M
    NONDESTRUCTIVE METHODS FOR MATERIALS CHARACTERIZATION, 2000, 591 : 175 - 180
  • [34] Determination of hydrogen in niobium by cold neutron prompt gamma-ray activation analysis and neutron incoherent scattering
    Paul, RL
    Chen-Mayer, HH
    Myneni, GR
    HYDROGEN IN MATERIALS AND VACUUM SYSTEMS, 2003, 671 : 151 - 161
  • [35] Use of spherical targets to minimize effects of neutron scattering by hydrogen in neutron capture prompt γ-ray activation analysis
    Mackey, Elizabeth A.
    Gordon, Glen E.
    Lindstrom, Richard M.
    Anderson, David L.
    Analytical Chemistry, 1992, 64 (20)
  • [36] The 30 m small-angle neutron scattering instruments at the National Institute of Standards and Technology
    Glinka, CJ
    Barker, JG
    Hammouda, B
    Krueger, S
    Moyer, JJ
    Orts, WJ
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 1998, 31 : 430 - 445
  • [37] Quantification of boron contents in BN/BCN composites by prompt gamma-ray neutron activation analysis utilizing thermal neutron beam at Dhruva reactor
    Lopamudra Acharya
    Rashmi Acharya
    Sk Wasim Raja
    Raghunath Acharya
    Kulamani Parida
    Journal of Radioanalytical and Nuclear Chemistry, 2020, 325 : 977 - 982
  • [38] Quantification of boron contents in BN/BCN composites by prompt gamma-ray neutron activation analysis utilizing thermal neutron beam at Dhruva reactor
    Acharya, Lopamudra
    Acharya, Rashmi
    Raja, Sk Wasim
    Acharya, Raghunath
    Parida, Kulamani
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2020, 325 (03) : 977 - 982
  • [39] Prompt gamma-ray neutron activation analysis of boron using Deuterium–Deuterium (D–D) neutron generator
    K. Bergaoui
    N. Reguigui
    C. K. Gary
    C. Brown
    J. T. Cremer
    J. H. Vainionpaa
    M. A. Piestrup
    Journal of Radioanalytical and Nuclear Chemistry, 2015, 303 : 115 - 121
  • [40] ABUNDANCE OF BORON IN INTERNATIONAL GEOCHEMICAL STANDARDS BY PROMPT-GAMMA NEUTRON-ACTIVATION ANALYSIS
    HIGGINS, MD
    GEOSTANDARDS NEWSLETTER, 1984, 8 (01): : 31 - 34