New thermal neutron prompt γ-ray activation analysis instrument at the National Institute of Standards and Technology Center for Neutron Research

被引:26
|
作者
Mackey, EA
Anderson, DL
Liposky, PJ
Lindstrom, RM
Chen-Mayer, H
Lamaze, GP
机构
[1] Natl Inst Stand & Technol, Div Analyt Chem, Gaithersburg, MD 20899 USA
[2] US FDA, Elemental Res Branch, College Pk, MD 20740 USA
[3] Natl Inst Stand & Technol, Ctr Neutron Res, Gaithersburg, MD 20899 USA
关键词
gamma-ray spectrometry; neutron beam; neutron capture; prompt gamma activation analysis; prompt gamma-rays;
D O I
10.1016/j.nimb.2004.05.038
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
A new thermal neutron prompt gamma-ray activation analysis (PGAA) instrument was designed and built to replace the original PGAA system at the NIST Center for Neutron Research. By placing a sapphire filter in the neutron beam shutter assembly, the fast neutron fluence rate was reduced by a factor of 5 and low-energy (50-200 keV) gamma-ray intensities were reduced by factors of 5-10. The thermal neutron fluence rate was reduced by only a factor of 1.13. A new external beam tube, sample chamber, beam stop, and support structure were built and a new detection system installed. The new beam tube is made of two cylindrical aluminum sections lined with a lithiated polymer. Both sections are kept under vacuum to reduce the number of neutrons scattered by air into the beam tube walls. The sample chamber is also fabricated from aluminum and lined with lithiated polymer, and may be evacuated to minimize the number of neutrons scattered and absorbed by air. The beam tube and sample chamber assembly is suspended from the aluminum support structure. The detection system consists of a 40% efficient (relative) germanium detector (resolution 2.0 at 1332.5 keV) and a bismuth germanate Compton suppressor. The detection system is shielded by lead, surrounded by borated and lithiated polyethylene, and placed on a table attached to the support structure. The new, more compact beam stop is welded to the support structure. Capture gamma-ray photopeaks from H, B, C, N, Na, Al, Fe, Ge, I and Pb in the background spectrum were either of lower intensity or eliminated with the new PGAA instrument. The more efficient detection system, positioned closer to the sample, yielded element sensitivity increases of 5-50%. Limits of detection have been greatly reduced compared with those of the original instrument due to reduced Compton and scattered gamma-ray backgrounds (especially in the low-energy region), increased sensitivities, and reduction of background gamma-ray photopeak intensities. Published by Elsevier B.V.
引用
收藏
页码:426 / 440
页数:15
相关论文
共 50 条
  • [1] Thermal neutron capture prompt gamma-ray activation analysis facility at the National Center for Neutron Research.
    Anderson, DL
    Mackey, EA
    Lamaze, GP
    Lindstrom, RM
    Chen-Mayer, HH
    Liposky, PJ
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2000, 220 : U22 - U22
  • [2] Rheo-small-angle neutron scattering at the National Institute of Standards and Technology Center for Neutron Research
    Porcar, L.
    Pozzo, D.
    Langenbucher, G.
    Moyer, J.
    Butler, P. D.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2011, 82 (08):
  • [3] The very small angle neutron scattering instrument at the National Institute of Standards and Technology
    Barker, John
    Moyer, James
    Kline, Steven
    Jensen, Grethe
    Cook, Jeremy
    Gagnon, Cedric
    Kelley, Elizabeth
    Chabot, Jean Philippe
    Maliszewskyj, Nicholas
    Parikh, Chirag
    Chen, Wangchun
    Murphy, R. P.
    Glinka, Charles
    JOURNAL OF APPLIED CRYSTALLOGRAPHY, 2022, 55 : 271 - 283
  • [4] Compton suppression for neutron activation analysis applications at the National Institute of Standards and Technology (NIST)
    Stover, T
    Lamaze, G
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 241 (1-4): : 223 - 227
  • [5] Neutron Interferometry at the National Institute of Standards and Technology
    Pushin, D. A.
    Huber, M. G.
    Arif, M.
    Shahi, C. B.
    Nsofini, J.
    Wood, C. J.
    Sarenac, D.
    Cory, D. G.
    ADVANCES IN HIGH ENERGY PHYSICS, 2015, 2015
  • [6] Concepts and Engineering Aspects of a Neutron Resonance Spin-Echo Spectrometer for the National Institute of Standards and Technology Center for Neutron Research
    Cook, Jeremy C.
    JOURNAL OF RESEARCH OF THE NATIONAL INSTITUTE OF STANDARDS AND TECHNOLOGY, 2014, 119 : 55 - 211
  • [7] Design of a new instrument for cold neutron prompt gamma-ray activation analysis at NIST
    Paul, R. L.
    Lindstrom, R. M.
    Brocker, C.
    Mackey, E. A.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 278 (03) : 697 - 701
  • [8] Design of a new instrument for cold neutron prompt gamma-ray activation analysis at NIST
    R. L. Paul
    R. M. Lindstrom
    C. Brocker
    E. A. Mackey
    Journal of Radioanalytical and Nuclear Chemistry, 2008, 278 : 697 - 701
  • [9] THE NATIONAL-INSTITUTE-OF-STANDARDS-AND-TECHNOLOGY COLD NEUTRON RESEARCH FACILITY AND MAGNETIC NEUTRON-SCATTERING
    RHYNE, JJ
    MAJKRZAK, CF
    JOURNAL OF APPLIED PHYSICS, 1990, 67 (09) : 5693 - 5698
  • [10] Improving neutron source calibrations at the National Institute of Standards and Technology
    Adams, JM
    Gilliam, DM
    REACTOR DOSIMETRY IN THE 21ST CENTURY, 2003, : 682 - 688