FPGA-based RF interference reduction techniques for simultaneous PET-MRI

被引:11
|
作者
Gebhardt, P. [1 ,2 ]
Wehner, J. [2 ]
Weissler, B. [2 ]
Botnar, R. [1 ]
Marsden, P. K. [1 ]
Schulz, V. [2 ,3 ]
机构
[1] Kings Coll London, Div Imaging Sci & Biomed Engn, London WC2R 2LS, England
[2] Rhein Westfal TH Aachen, Inst Expt Mol Imaging, Dept Phys Mol Imaging Syst, D-52062 Aachen, Germany
[3] Philips Res Europe, D-52066 Aachen, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 09期
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
PET-MRI; RF interference reduction; MR compatibility; FPGA; digital; SiPM; POSITRON-EMISSION-TOMOGRAPHY; DIGITAL SILICON PHOTOMULTIPLIER; PET/MRI INSERT; ACQUISITION; OPERATION; DETECTOR; SYSTEM; IMAGES;
D O I
10.1088/0031-9155/61/9/3500
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The combination of positron emission tomography (PET) and magnetic resonance imaging (MRI) as a multi-modal imaging technique is considered very promising and powerful with regard to in vivo disease progression examination, therapy response monitoring and drug development. However, PET-MRI system design enabling simultaneous operation with unaffected intrinsic performance of both modalities is challenging. As one of the major issues, both the PET detectors and the MRI radio-frequency (RF) subsystem are exposed to electromagnetic (EM) interference, which may lead to PET and MRI signal-to-noise ratio (SNR) deteriorations. Early digitization of electronic PET signals within the MRI bore helps to preserve PET SNR, but occurs at the expense of increased amount of PET electronics inside the MRI and associated RF field emissions. This raises the likelihood of PET-related MRI interference by coupling into the MRI RF coil unwanted spurious signals considered as RF noise, as it degrades MRI SNR and results in MR image artefacts. RF shielding of PET detectors is a commonly used technique to reduce PET-related RF interferences, but can introduce eddy-current-related MRI disturbances and hinder the highest system integration. In this paper, we present RF interference reduction methods which rely on EM field coupling-decoupling principles of RF receive coils rather than suppressing emitted fields. By modifying clock frequencies and changing clock phase relations of digital circuits, the resulting RF field emission is optimised with regard to a lower field coupling into the MRI RF coil, thereby increasing the RF silence of PET detectors. Our methods are demonstrated by performing FPGA-based clock frequency and phase shifting of digital silicon photo-multipliers (dSiPMs) used in the PET modules of our MR-compatible Hyperion IID PET insert. We present simulations and magnetic-field map scans visualising the impact of altered clock phase pattern on the spatial RF field distribution, followed by MRI noise and SNR scans performed with an operating PET module using different clock frequencies and phase patterns. The methods were implemented via firmware design changes without any hardware modifications. This introduces new means of flexibility by enabling adaptive RF interference reduction optimisations in the field, e.g. when using a PET insert with different MRI systems or when different MRI RF coil types are to be operated with the same PET detector.
引用
收藏
页码:3500 / +
页数:27
相关论文
共 50 条
  • [31] FPGA-based accurate star segmentation with moon interference
    Jie Jiang
    Keji Chen
    Journal of Real-Time Image Processing, 2019, 16 : 1289 - 1299
  • [32] HARDWARE REDUCTION IN FPGA-BASED MOORE FSM
    Barkalov, Alexander
    Titarenko, Larysa
    Malcheva, Raisa
    Soldatov, Kyryll
    JOURNAL OF CIRCUITS SYSTEMS AND COMPUTERS, 2013, 22 (03)
  • [33] Simplified FPGA-based data acquisition system for PET
    Laymon, CM
    Miyaoka, RS
    Park, BK
    Lewellen, TK
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 704 - 707
  • [34] Optimized RF shielding techniques for simultaneous PET/MR
    Truhn, D.
    Kiessling, F.
    Schulz, V.
    MEDICAL PHYSICS, 2011, 38 (07) : 3995 - 4000
  • [35] Simplified FPGA-based data acquisition system for PET
    Laymon, CM
    Miyaoka, RS
    Park, BK
    Lewellen, TK
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2003, 50 (05) : 1483 - 1486
  • [36] Studies of Electromagnetic Interference of PET Detector Insert for Simultaneous PET/MRI
    Lee, Brian J.
    Olcott, Peter D.
    Hong, Key Jo
    Grant, Alexander M.
    Chang, Chen-Ming
    Levin, Craig S.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [37] Simultaneous PET-MRI Confirms That Cerebral Blood Flow Does Not Confound PET Neuroreceptor Activation Studies
    Nummenmaa, Lauri
    Tuominen, Lauri
    Hirvonen, Jussi
    ACS CHEMICAL NEUROSCIENCE, 2018, 9 (02): : 159 - 161
  • [38] TCGFusion: a network for PET-MRI fusion based on GAN and transformer
    Fan, Chao
    Chen, Zhixiang
    Lin, Hao
    Wang, Xiao
    Multimedia Tools and Applications, 2024, 83 (13) : 37505 - 37522
  • [39] TCGFusion: a network for PET-MRI fusion based on GAN and transformer
    Chao Fan
    Zhixiang Chen
    Hao Lin
    Xiao Wang
    Multimedia Tools and Applications, 2024, 83 : 37505 - 37522
  • [40] TCGFusion: a network for PET-MRI fusion based on GAN and transformer
    Fan, Chao
    Chen, Zhixiang
    Lin, Hao
    Wang, Xiao
    MULTIMEDIA TOOLS AND APPLICATIONS, 2023, 83 (13) : 37505 - 37522