FPGA-based RF interference reduction techniques for simultaneous PET-MRI

被引:11
|
作者
Gebhardt, P. [1 ,2 ]
Wehner, J. [2 ]
Weissler, B. [2 ]
Botnar, R. [1 ]
Marsden, P. K. [1 ]
Schulz, V. [2 ,3 ]
机构
[1] Kings Coll London, Div Imaging Sci & Biomed Engn, London WC2R 2LS, England
[2] Rhein Westfal TH Aachen, Inst Expt Mol Imaging, Dept Phys Mol Imaging Syst, D-52062 Aachen, Germany
[3] Philips Res Europe, D-52066 Aachen, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 09期
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
PET-MRI; RF interference reduction; MR compatibility; FPGA; digital; SiPM; POSITRON-EMISSION-TOMOGRAPHY; DIGITAL SILICON PHOTOMULTIPLIER; PET/MRI INSERT; ACQUISITION; OPERATION; DETECTOR; SYSTEM; IMAGES;
D O I
10.1088/0031-9155/61/9/3500
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The combination of positron emission tomography (PET) and magnetic resonance imaging (MRI) as a multi-modal imaging technique is considered very promising and powerful with regard to in vivo disease progression examination, therapy response monitoring and drug development. However, PET-MRI system design enabling simultaneous operation with unaffected intrinsic performance of both modalities is challenging. As one of the major issues, both the PET detectors and the MRI radio-frequency (RF) subsystem are exposed to electromagnetic (EM) interference, which may lead to PET and MRI signal-to-noise ratio (SNR) deteriorations. Early digitization of electronic PET signals within the MRI bore helps to preserve PET SNR, but occurs at the expense of increased amount of PET electronics inside the MRI and associated RF field emissions. This raises the likelihood of PET-related MRI interference by coupling into the MRI RF coil unwanted spurious signals considered as RF noise, as it degrades MRI SNR and results in MR image artefacts. RF shielding of PET detectors is a commonly used technique to reduce PET-related RF interferences, but can introduce eddy-current-related MRI disturbances and hinder the highest system integration. In this paper, we present RF interference reduction methods which rely on EM field coupling-decoupling principles of RF receive coils rather than suppressing emitted fields. By modifying clock frequencies and changing clock phase relations of digital circuits, the resulting RF field emission is optimised with regard to a lower field coupling into the MRI RF coil, thereby increasing the RF silence of PET detectors. Our methods are demonstrated by performing FPGA-based clock frequency and phase shifting of digital silicon photo-multipliers (dSiPMs) used in the PET modules of our MR-compatible Hyperion IID PET insert. We present simulations and magnetic-field map scans visualising the impact of altered clock phase pattern on the spatial RF field distribution, followed by MRI noise and SNR scans performed with an operating PET module using different clock frequencies and phase patterns. The methods were implemented via firmware design changes without any hardware modifications. This introduces new means of flexibility by enabling adaptive RF interference reduction optimisations in the field, e.g. when using a PET insert with different MRI systems or when different MRI RF coil types are to be operated with the same PET detector.
引用
收藏
页码:3500 / +
页数:27
相关论文
共 50 条
  • [21] FPGA-based Deep Learning Accelerator for RF Applications
    den Boer, H.
    Muller, R. W. D.
    Wong, S.
    Voogt, V.
    2021 IEEE MILITARY COMMUNICATIONS CONFERENCE (MILCOM 2021), 2021,
  • [22] Enhanced RF Power Leveling with FPGA-Based Instrumentation
    Nelson, James Haydn
    Buritica, Alejandro
    IEEE MICROWAVE MAGAZINE, 2013, 14 (07) : 108 - +
  • [23] An FPGA-based Technique for Linearizing RF Power Amplifiers
    Mahmoodi, Mohammad Reza
    Fahimi, Zahra
    2015 2ND INTERNATIONAL CONFERENCE ON KNOWLEDGE-BASED ENGINEERING AND INNOVATION (KBEI), 2015, : 36 - 42
  • [24] Interfacing Techniques for FPGA-based Distributed Simulation
    Kredo, Kurtis, II
    Zenor, John J.
    Yusta, Jowel
    Moore, Daniel
    Mish, Sam
    PROCEEDINGS OF THE 2012 GRAND CHALLENGES IN MODELING & SIMULATION (GCMS '12), 2012, 44 (11): : 120 - 125
  • [25] A FPGA-Based High Speed Multi-Channel Simultaneous Signal Acquisition Method for PET
    Hu, W.
    Choi, Y.
    Jung, J. H.
    Kang, J. H.
    Min, B. J.
    Huh, Y. S.
    Shin, S. H.
    Lim, H. K.
    Chung, Y. H.
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2870 - +
  • [26] FPGA-based implementation of classification techniques: A survey
    Saidi, Afef
    Ben Othman, Slim
    Dhouibi, Meriam
    Ben Saoud, Slim
    INTEGRATION-THE VLSI JOURNAL, 2021, 81 : 280 - 299
  • [27] Simultaneous PET-MRI reconstruction with vectorial second order total generalized variation
    Knoll, Florian
    Holler, Martin
    Koesters, Thomas
    Bredies, Kristian
    Sodickson, Daniel K.
    2015 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2015,
  • [28] RF-Transmissive PET Detector Insert for Simultaneous PET/MRI
    Lee, Brian J.
    Grant, Alexander M.
    Chang, Chen-Ming
    Glover, Gary H.
    Levin, Craig S.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
  • [29] Understanding and Mitigating Memory Interference in FPGA-based HeSoCs
    Brilli, Gianluca
    Capotondi, Alessandro
    Burgio, Paolo
    Marongiu, Andrea
    PROCEEDINGS OF THE 2022 DESIGN, AUTOMATION & TEST IN EUROPE CONFERENCE & EXHIBITION (DATE 2022), 2022, : 1335 - 1340
  • [30] FPGA-based accurate star segmentation with moon interference
    Jiang, Jie
    Chen, Keji
    JOURNAL OF REAL-TIME IMAGE PROCESSING, 2019, 16 (04) : 1289 - 1299