FPGA-based RF interference reduction techniques for simultaneous PET-MRI

被引:11
|
作者
Gebhardt, P. [1 ,2 ]
Wehner, J. [2 ]
Weissler, B. [2 ]
Botnar, R. [1 ]
Marsden, P. K. [1 ]
Schulz, V. [2 ,3 ]
机构
[1] Kings Coll London, Div Imaging Sci & Biomed Engn, London WC2R 2LS, England
[2] Rhein Westfal TH Aachen, Inst Expt Mol Imaging, Dept Phys Mol Imaging Syst, D-52062 Aachen, Germany
[3] Philips Res Europe, D-52066 Aachen, Germany
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 09期
基金
英国工程与自然科学研究理事会; 英国惠康基金;
关键词
PET-MRI; RF interference reduction; MR compatibility; FPGA; digital; SiPM; POSITRON-EMISSION-TOMOGRAPHY; DIGITAL SILICON PHOTOMULTIPLIER; PET/MRI INSERT; ACQUISITION; OPERATION; DETECTOR; SYSTEM; IMAGES;
D O I
10.1088/0031-9155/61/9/3500
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The combination of positron emission tomography (PET) and magnetic resonance imaging (MRI) as a multi-modal imaging technique is considered very promising and powerful with regard to in vivo disease progression examination, therapy response monitoring and drug development. However, PET-MRI system design enabling simultaneous operation with unaffected intrinsic performance of both modalities is challenging. As one of the major issues, both the PET detectors and the MRI radio-frequency (RF) subsystem are exposed to electromagnetic (EM) interference, which may lead to PET and MRI signal-to-noise ratio (SNR) deteriorations. Early digitization of electronic PET signals within the MRI bore helps to preserve PET SNR, but occurs at the expense of increased amount of PET electronics inside the MRI and associated RF field emissions. This raises the likelihood of PET-related MRI interference by coupling into the MRI RF coil unwanted spurious signals considered as RF noise, as it degrades MRI SNR and results in MR image artefacts. RF shielding of PET detectors is a commonly used technique to reduce PET-related RF interferences, but can introduce eddy-current-related MRI disturbances and hinder the highest system integration. In this paper, we present RF interference reduction methods which rely on EM field coupling-decoupling principles of RF receive coils rather than suppressing emitted fields. By modifying clock frequencies and changing clock phase relations of digital circuits, the resulting RF field emission is optimised with regard to a lower field coupling into the MRI RF coil, thereby increasing the RF silence of PET detectors. Our methods are demonstrated by performing FPGA-based clock frequency and phase shifting of digital silicon photo-multipliers (dSiPMs) used in the PET modules of our MR-compatible Hyperion IID PET insert. We present simulations and magnetic-field map scans visualising the impact of altered clock phase pattern on the spatial RF field distribution, followed by MRI noise and SNR scans performed with an operating PET module using different clock frequencies and phase patterns. The methods were implemented via firmware design changes without any hardware modifications. This introduces new means of flexibility by enabling adaptive RF interference reduction optimisations in the field, e.g. when using a PET insert with different MRI systems or when different MRI RF coil types are to be operated with the same PET detector.
引用
收藏
页码:3500 / +
页数:27
相关论文
共 50 条
  • [1] RF interference reduction for simultaneous digital PET/MR using an FPGA-based, optimized spatial and temporal clocking distribution
    Gebhardt, P.
    Wehner, J.
    Weissler, B.
    Kiessling, F.
    Marsden, P. K.
    Schulz, V.
    2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [2] Shielded transceiver RF coil array for simultaneous PET-MRI
    Solis, E.
    Tomasi, D.
    Junnarkar, S.
    Schlyer, D.
    Vaska, P.
    Woody, C.
    Pratte, J-F.
    O'Connor, P.
    Rodriguez, A. O.
    BRAZILIAN JOURNAL OF PHYSICS, 2008, 38 (02) : 287 - 291
  • [3] All-digital FPGA-based RF pulsed transmitter with hardware complexity reduction techniques
    de Menezes, Nagila Ribeiro
    Hernandez, Hugo Daniel
    Carvalho, Dionisio
    Van Noije, Wilhelmus
    33RD SYMPOSIUM ON INTEGRATED CIRCUITS AND SYSTEMS DESIGN (SBCCI 2020), 2020,
  • [4] Split Gradient Coils for Simultaneous PET-MRI
    Poole, Michael
    Bowtell, Richard
    Green, Dan
    Pittard, Simon
    Lucas, Alun
    Hawkes, Rob
    Carpenter, Adrian
    MAGNETIC RESONANCE IN MEDICINE, 2009, 62 (05) : 1106 - 1111
  • [5] Prototype integrated system of DOI-PET and the RF-coil specialized for simultaneous PET-MRI measurements
    Nishikido, Fumihiko
    Obata, Takayuki
    Inadama, Naoko
    Yoshida, Eiji
    Tashima, Hideaki
    Suga, Mikio
    Murayama, Hideo
    Ito, Hiroshi
    Yamaya, Taiga
    2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 2750 - 2752
  • [6] Feasibility study for a PET detector integrated with an RF coil for PET-MRI
    Nishikido, Fumihiko
    Tachibana, Atsushi
    Obata, Takayuki
    Yoshioka, Shunsuke
    Inadama, Naoko
    Yoshida, Eiji
    Tashima, Hideaki
    Suga, Mikio
    Murayama, Hideo
    Yamaya, Taiga
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3183 - 3186
  • [7] Results from a simultaneous PET-MRI breast scanner
    Ravindranath, Bosky
    Junnarkar, Sachin
    Purschke, Martin
    Stoll, Sean
    Hong, Xiaole
    Huang, Pai-Jung
    Maramraju, Harsha
    Vaska, Paul
    Woody, Craig
    Schlyer, David
    JOURNAL OF NUCLEAR MEDICINE, 2011, 52
  • [8] Performance improvement with respiratory gated PET using simultaneous PET-MRI
    Trott, Cathryn
    El Fakhri, Georges
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [9] Simultaneous PET-MRI m oncology: a solution looking for a problem?
    Yankeelov, Thomas E.
    Peterson, Todd E.
    Abramson, Richard G.
    Garcia-Izquierdo, David
    Arlinghaus, Lori R.
    Li, Xia
    Atuegwu, Nkiruka C.
    Catana, Ciprian
    Manning, H. Charles
    Fayad, Zahi A.
    Gore, John C.
    MAGNETIC RESONANCE IMAGING, 2012, 30 (09) : 1342 - 1356
  • [10] Simultaneous PET-MRI:: a new approach for functional and morphological imaging
    Judenhofer, Martin S.
    Wehrl, Hans F.
    Newport, Danny F.
    Catana, Ciprian
    Siegel, Stefan B.
    Becker, Markus
    Thielscher, Axel
    Kneilling, Manfred
    Lichy, Matthias P.
    Eichner, Martin
    Klingel, Karin
    Reischl, Gerald
    Widmaier, Stefan
    Roecken, Martin
    Nutt, Robert E.
    Machulla, Hans-Juergen
    Uludag, Kamil
    Cherry, Simon R.
    Claussen, Claus D.
    Pichler, Bernd J.
    NATURE MEDICINE, 2008, 14 (04) : 459 - 465