Voltammetric determination of the neonicotinoid insecticide thiamethoxam using a tricresyl phosphate-based carbon paste electrode

被引:25
|
作者
Papp, Zsigmond J. [1 ]
Guzsvany, Valeria J. [1 ]
Kubiak, Szymon [2 ]
Bobrowski, Andrzej [2 ]
Bjelica, Luka J. [1 ]
机构
[1] Univ Novi Sad, Dept Chem Biochem & Environm Protect, Fac Sci, Novi Sad 21000, Serbia
[2] AGH Univ Sci & Technol, Dept Bldg Mat Technol, Fac Mat Sci & Ceram, PL-30059 Krakow, Poland
关键词
pesticide; thiamethoxam; differential pulse voltammetry; carbon paste electrode; tricresyl phosphate; SOLID-PHASE EXTRACTION; PULSE POLAROGRAPHIC-DETERMINATION; BISMUTH FILM ELECTRODE; DIODE-ARRAY DETECTION; LIQUID-CHROMATOGRAPHY; MASS-SPECTROMETRY; COMMERCIAL FORMULATIONS; RESIDUES; CLEANUP; SAMPLES;
D O I
10.2298/JSC090624033P
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
The objective of the work was to investigate the possibility of using a tricresyl phosphate-based carbon paste electrode for the direct voltammetric determination of the neonicotinoid insecticide thiamethoxam. The analyte was determined by differential pulse voltammetry in Britton-Robinson buffer pH 7.0 in the concentration range of 3.72-41.5 mu g mL(-1). The reproducibility of the analytical signal at the 7.29 mu g mL(-1) level was characterized by a relative standard deviation of 1.3 %. The applicability of the developed method was evaluated by determining thiamethoxam in a river water sample and a commercial formulation Actara 25 WG.
引用
收藏
页码:681 / 687
页数:7
相关论文
共 50 条
  • [31] Voltammetric determination of diethylstilbestrol at carbon paste electrode using cetylpyridine bromide as medium
    Zhang, SH
    Wu, KB
    Hu, SS
    TALANTA, 2002, 58 (04) : 747 - 754
  • [32] Voltammetric Determination of Estrogens Based on the Enhancement Effect of Surfactant at Carbon Paste Electrode
    Wu Kang bing 1
    2. Department of Chemistry
    WuhanUniversityJournalofNaturalSciences, 2002, (04) : 463 - 469
  • [33] Determination of ultra-trace amounts of neonicotinoid insecticide imidacloprid by cyclic and square wave voltammetric methods using pretreated glassy carbon electrode
    Ben Brahim, M.
    Elahmadi, M. F.
    Ammar, H. B.
    Samet, Y.
    GLOBAL NEST JOURNAL, 2018, 20 (03): : 628 - 636
  • [34] VOLTAMMETRIC DETERMINATION OF NITRATE WITH A MODIFIED CARBON-PASTE ELECTRODE
    NEUHOLD, C
    KALCHER, K
    DIEWALD, W
    CAI, XH
    RABER, G
    ELECTROANALYSIS, 1994, 6 (03) : 227 - 236
  • [35] Adsorptive voltammetric determination of cisapride on carbon nanotubes paste electrode
    Zheng Li
    Song Jun-Feng
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2007, 35 (07) : 1018 - 1020
  • [36] Voltammetric behavior and determination of tanshinone II A at carbon paste electrode
    Tian Xinjuan
    Song Junfeng
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2006, 34 (09) : 1283 - 1286
  • [37] Voltammetric determination of bisphenol a using a carbon paste electrode based on the enhancement effect of cetyltrimethylammonium bromide (CTAB)
    Huang, WS
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2005, 26 (10): : 1560 - 1564
  • [38] Electrochemical Determination of Adrenaline Using Voltammetric Sensor Employing NiO/CNTs Based Carbon Paste Electrode
    Gupta, Vinod Kumar
    Mahmoody, Hamide
    Karimi, Fatemeh
    Agarwal, Shilpi
    Abbasghorbani, Maryam
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2017, 12 (01): : 248 - 257
  • [39] Simultaneous anodic stripping voltammetric determination of lead and cadmium with a carbon paste electrode modified by tributyl phosphate
    Huang, SS
    Cheng, YD
    Li, BF
    Liu, GD
    MIKROCHIMICA ACTA, 1998, 130 (1-2) : 97 - 101
  • [40] Simultaneous anodic stripping voltammetric determination of lead and cadmium with a carbon paste electrode modified by tributyl phosphate
    Sha-Sheng Huang
    Yi-Da Cheng
    Bi-Fen Li
    Guo-Dong Liu
    Microchimica Acta, 1998, 130 : 97 - 101