Voltammetric determination of diethylstilbestrol at carbon paste electrode using cetylpyridine bromide as medium

被引:84
|
作者
Zhang, SH
Wu, KB
Hu, SS [1 ]
机构
[1] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
[2] Hubei Inst National, Dept Chem, Enshi 445000, Peoples R China
基金
中国国家自然科学基金;
关键词
voltammetry; diethylstilbestrol; surfactant; carbon paste electrode;
D O I
10.1016/S0039-9140(02)00367-3
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In this paper, the voltammetric properties of diethylstilbestrol (DES) at the carbon paste electrode were described. The oxidation peak currents of DES increase significantly in the presence of surfactant cetylpyridine bromide (CPB), compared with that in the absence of CPB. Based on this fact, a voltammetric technique for determining DES is proposed. The accumulation potential has no effects on the peak current of the DES. An open-circuit accumulation is carried out. The experimental parameters, such as pH value of buffer, scan rate, and accumulation time were optimized. The interferences of some metal ions and organic compounds have also been studied, and some metal ions almost do not interfere with the determination of DES. Using this voltammetric method, DES in the injection sample was measured. The results show that this voltammetric method is reliable for the practice determination of DES. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:747 / 754
页数:8
相关论文
共 50 条
  • [1] VOLTAMMETRIC DETERMINATION OF PALLADIUM USING A CARBON PASTE ELECTRODE
    KRAPIVKINA, TA
    NOSACHEVA, VV
    INDUSTRIAL LABORATORY, 1977, 43 (03): : 321 - 323
  • [2] Voltammetric determination of bisphenol a using a carbon paste electrode based on the enhancement effect of cetyltrimethylammonium bromide (CTAB)
    Huang, WS
    BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2005, 26 (10): : 1560 - 1564
  • [3] Anodic stripping voltammetric determination of titanium(IV) using a carbon paste electrode modified with cetyltrimethylammonium bromide
    Stadlober, M
    Kalcher, K
    Raber, G
    Neuhold, C
    TALANTA, 1996, 43 (11) : 1915 - 1924
  • [4] Voltammetric determination of selected aminoquinolines using carbon paste electrode
    Zima, J
    Stoica, AI
    Zítová, A
    Barek, J
    ELECTROANALYSIS, 2006, 18 (02) : 158 - 162
  • [5] Voltammetric determination of bisphenol A using modified carbon paste electrode
    Jahani, Peyman Mohammadzadeh
    Beitollahi, Hadi
    Nejad, Fariba Garkani
    INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 2024,
  • [6] Voltammetric determination of lactate dehydrogenase using a carbon paste electrode
    Tarmure, C
    Sandulescu, R
    Ionescu, C
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2000, 22 (02) : 355 - 361
  • [7] Voltammetric Oxidation and Determination of Atenolol Using a Carbon Paste Electrode
    Patil, Roopa H.
    Hegde, Rajesh N.
    Nandibewoor, S. T.
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2009, 48 (23) : 10206 - 10210
  • [8] Voltammetric determination of azithromycin at the carbon paste electrode
    Farghaly, OA
    Mohamed, NAL
    TALANTA, 2004, 62 (03) : 531 - 538
  • [9] Anodic stripping voltammetric determination of vanadium(v) using a carbon paste electrode modified in situ with cetyltrimethylammonium bromide
    Stadlober, M
    Kalcher, K
    Raber, G
    ELECTROANALYSIS, 1997, 9 (03) : 225 - 230
  • [10] A VOLTAMMETRIC TECHNIQUE USING A MODIFIED CARBON PASTE ELECTRODE FOR THE DETERMINATION OF ACLONIFEN
    Novotny, Vit
    Barek, Jiri
    ECOLOGICAL CHEMISTRY AND ENGINEERING S-CHEMIA I INZYNIERIA EKOLOGICZNA S, 2015, 22 (03): : 451 - 458