A portal image based quality assurance program using a commercial portal dosimetry software

被引:0
|
作者
Guerrero, M. [1 ]
Patel, I. [1 ]
机构
[1] Dept Vet Affairs Med Ctr, Washington, DC USA
关键词
D O I
10.1118/1.2760375
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: There is an increasing trend in Radiation Oncology Departments to replace film as a tool for localization hence Medical Physicists increasingly find themselves without access to a film processor. Films are typically used for standard routine quality assurance (QA) of linear accelerators and IMRT commissioning and verifications. The purpose of this work is to develop a QA program using a commercial electronic portal imager (EPID) and commercial portal dosimetry software available on Varian Linear Accelerators. Method and Materials: Using Varian aS500 Portal Imager with the Portal Dosimetry Calculation (PDC) from Eclipse (commissioned according to manufacturer's recommendations), we perform a series of measurements associated with Linac QA (light‐field coincidence, flatness and symmetry, off‐axis ratios, etc), IMRT verifications and static and dynamic MLC QA. For light‐filed coincidence we use the gradicule to “mark” the edges of the light field. For flatness and symmetry we determine a “baseline” using a phantom measurement at 10cm depth and establishing a correspondence with the Portal Imager measurement. Similar baselines are established for off‐axis ratios and other measurements. Results: We present the results of our QA measurements; analyze their level of difficulty and convenience as compared with the use of film. The QA measurements performed with the portal imager are consistent with the results from our film measurements. The IMRT verifications performed with the EPID are also consistent with the ones performed with our commercial two‐dimensional diode array. We find that after we became familiar with the use of the Portal Imager and the software, the QA measurements with the portal imager are adequate and in many cases more convenient than the use of film. Conclusion: An appropriate Linac and IMRT QA program can be developed using the Varian aS500 EPID in combination with the Eclipse Portal Dosimetry Calculation. © 2007, American Association of Physicists in Medicine. All rights reserved.
引用
收藏
页码:2337 / 2337
页数:1
相关论文
共 50 条
  • [1] IMRT/VMAT Quality Assurance Using Portal Dosimetry
    Pan, X.
    Ochran, T.
    Bradley, W.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [2] Evaluation of HyperArc™ using film and portal dosimetry quality assurance
    Onno Kamst
    P. Desai
    Physical and Engineering Sciences in Medicine, 2023, 46 : 57 - 66
  • [3] Quality assurance of RapidArc in clinical practice using portal dosimetry
    Fogliata, A.
    Clivio, A.
    Fenoglietto, P.
    Hrbacek, J.
    Kloeck, S.
    Lattuada, P.
    Mancosu, P.
    Nicolini, G.
    Parietti, E.
    Urso, G.
    Vanetti, E.
    Cozzi, L.
    BRITISH JOURNAL OF RADIOLOGY, 2011, 84 (1002): : 534 - 545
  • [4] Evaluation of HyperArc™ using film and portal dosimetry quality assurance
    Kamst, Onno
    Desai, P.
    PHYSICAL AND ENGINEERING SCIENCES IN MEDICINE, 2023, 46 (01) : 57 - 66
  • [5] Single Target Radiosurgery Quality Assurance with Portal Dosimetry
    Covington, E.
    Snyder, J.
    Wu, X.
    Popple, R.
    MEDICAL PHYSICS, 2017, 44 (06) : 2886 - 2886
  • [6] Practical Application of a Portal Dosimetry Device for Daily Inspections in an Electron Accelerator Quality Assurance Program
    Kazantsev P.V.
    Lebedenko I.M.
    Krylova T.A.
    Prusova M.P.
    Jourov U.V.
    Klimanov V.A.
    Biomedical Engineering, 2016, 50 (1) : 70 - 74
  • [7] Portal dosimetry prediction using Pinnacle ® TPS for clinical quality assurance applications.
    Fawzi, M.
    Cerbah, Y.
    Eid, D.
    Mohamad, M. Alabdoaburas
    Sandjon, M.
    Belshi, R.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S730 - S730
  • [8] Assessing the feasibility of single target radiosurgery quality assurance with portal dosimetry
    Covington, Elizabeth L.
    Snyder, Jesse D.
    Wu, Xingen
    Cardan, Rex A.
    Popple, Richard A.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2019, 20 (05): : 135 - 140
  • [9] Patient Specific Quality Assurance of Prostate VMAT Plans with Portal Dosimetry
    Darko, J.
    Kiciak, A.
    Badu, S.
    Grigorov, G.
    Fleck, A.
    Osei, E.
    MEDICAL PHYSICS, 2016, 43 (06) : 3525 - 3525
  • [10] Patient Specific IMRT Pre-Treatment Verification Using A Commercial Portal Dosimetry Software
    Varatharaj, C.
    Moretti, E.
    Manickam, R.
    Padovani, R.
    MEDICAL PHYSICS, 2012, 39 (06) : 3788 - 3788