Biomechanical evaluation of anterior cervical spine stabilization

被引:79
|
作者
Grubb, MR [1 ]
Currier, BL [1 ]
Shih, JS [1 ]
Bonin, V [1 ]
Grabowski, JJ [1 ]
Chao, EYS [1 ]
机构
[1] Mayo Clin & Mayo Fdn, Dept Orthoped, Rochester, MN 55905 USA
关键词
biomechanics; cervical spine; spinal instrumentation;
D O I
10.1097/00007632-199804150-00009
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. An in vitro biomechanical study. Objectives. To simulate a severe compressive flexion injury for determination of the relative stability of different anterior instrumentation systems in a porcine model and to validate this model in human cadaveric specimen. Summary of Background Data. Anterior plate fixation is useful for high-grade mechanical insufficiency of the cervical spine and may prevent the need for a second procedure. Methods. The cervical spines of 45 porcine and 12 cadaveric specimens were subjected to nondestructive flexion, lateral bending, and torsional testing on a modified universal testing machine. A corpectomy was performed with release of the posterior ligamentous structures. The specimens were stabilized with one of three anterior plate constructs. The nondestructive testing was repeated to evaluate structural stability (stiffness and neutral zone). Finally, destructive testing examined failure moment, energy to failure, and mechanism of failure. Results. The instrumented specimens had flexural and lateral bending and torsional stiffness values that were similar to or greater than those of their paired intact specimens. The cervical spine locking plate had a significantly higher flexural stiffness ratio (plated:intact), torsional stiffness ratio, lower flexural neutral zone ratio, higher failure moment, and higher energy to failure than did the Caspar plate. Conclusions. The cervical spine locking plate is theoretically safer than the Caspar system because the posterior vertebral body cortex is not breached by the fixation screws, and the screws are less likely to back out anteriorly and irritate the esophagus. According to these results, the cervical spine locking plate system is biomechanically equivalent to and in some cases more stable than the Caspar system for fixation of a severe compressive flexion injury.
引用
收藏
页码:886 / 892
页数:7
相关论文
共 50 条
  • [31] Biomechanical Evaluation of Anterior Thoracic Salvage Screws in the Osteoporotic Thoracic Spine
    Behrend, Caleb
    George, Stephen
    Molinari, Robert
    JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2013, 26 (06): : E235 - E239
  • [32] Comparative studies of cervical spine anterior stabilization systems - Finite element analysis
    Mackiewicz, A.
    Banach, M.
    Denisiewicz, A.
    Bedzinski, R.
    CLINICAL BIOMECHANICS, 2016, 32 : 72 - 79
  • [33] ANTERIOR PLATE STABILIZATION FOR FRACTURE-DISLOCATIONS OF THE LOWER CERVICAL-SPINE
    BOHLER, J
    GAUDERNAK, T
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 1980, 20 (03): : 203 - 205
  • [34] Biomechanical comparison of anterior cervical spine locked and unlocked plate-fixation systems
    Lehmann, W
    Briem, D
    Blauth, M
    Schmidt, U
    EUROPEAN SPINE JOURNAL, 2005, 14 (03) : 243 - 249
  • [35] Biomechanical comparison of anterior cervical spine locked and unlocked plate-fixation systems
    Wolfgang Lehmann
    Daniel Briem
    Michael Blauth
    Ulf Schmidt
    European Spine Journal, 2005, 14 : 243 - 249
  • [36] Cervical spine stabilization by plate-cage. Clinical evaluation
    Hakalo, Jerzy
    Wronski, Jerzy
    NEUROLOGIA I NEUROCHIRURGIA POLSKA, 2007, 41 (01) : 44 - 54
  • [37] BIOMECHANICAL EVALUATION OF CERVICAL SPINE INSTABILITY AFTER MULTIPLE LEVEL LAMINECTOMY
    丁少峰
    张志玉
    蒋知节
    顾湘杰
    李鸿儒
    王以进
    CHINESE MEDICAL JOURNAL, 1991, (08)
  • [38] BIOMECHANICAL EVALUATION OF CERVICAL SPINE INSTABILITY AFTER MULTIPLE LEVEL LAMINECTOMY
    丁少峰
    张志玉
    蒋知节
    顾湘杰
    李鸿儒
    王以进
    中华医学杂志(英文版), 1991, (08) : 626 - 633
  • [39] Biomechanical evaluation of different suture anchors for the stabilization of anterior labrum lesions
    Mueller, MB
    Fredrich, HH
    Steinhauser, E
    Schreiber, U
    Arians, A
    Imhoff, AB
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2005, 21 (05): : 611 - 619
  • [40] STABILIZATION OF THE CERVICAL-SPINE
    EVANS, DK
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (01): : 1 - 2