Compact x-ray generator utilizing cerium-target tube for angiography

被引:0
|
作者
Sato, E [1 ]
Tanaka, E [1 ]
Mori, H [1 ]
Kawai, T [1 ]
Ito, F [1 ]
Ichimaru, T [1 ]
Sato, S [1 ]
Takayama, K [1 ]
Ido, H [1 ]
机构
[1] Iwate Med Univ, Dept Phys, Morioka, Iwate 0200015, Japan
来源
X-RAY SOURCES AND OPTICS | 2004年 / 5537卷
关键词
x-ray tube; cerium target; quasi-monochromatic x rays; characteristic x rays; K-edge angiography;
D O I
10.1117/12.560534
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The cerium-target x-ray tube is useful in order to perform cone beam K-edge angiography because K-series characteristic x rays from the cerium target are absorbed effectively by iodine-based contrast mediums. The x-ray generator consists of a main controller and a unit with a high-voltage circuit and a fixed anode x-ray tube. The tube is a glass-enclosed diode with a cerium target and a 0.5 mm-thick beryllium window. The maximum tube voltage and current were 65 kV and 0.4 mA, respectively, and the focal-spot sizes were 1.3x0.9 mm. Cerium K-series characteristic x rays were left using a 3.0 mm-thick aluminum filter, and the x-ray intensity was 0.59 muC/kg at 1.0 m from the source with a tube voltage of 60 kV, a current of 0.40 mA, and an exposure time of 1.0 s. Angiography was performed with a computed radiography system using iodine-based microspheres 15 mum in diameter. In angiography of non-living animals, we observed fine blood vessels of approximately 100 mum with high contrasts.
引用
收藏
页码:75 / 81
页数:7
相关论文
共 50 条
  • [31] THE COMPARISON OF MONOCHROMATIC X-RAY SOURCES BASED ON COMPACT ELECTRON ACCELERATORS AND X-RAY TUBE
    Adischev, Yu N.
    Popov, Yu. A.
    Potylitsyn, A. P.
    Wagner, A. R.
    Uglov, S. R.
    Zabaev, V. N.
    CHARGED AND NEUTRAL PARTICLES CHANNELING PHENOMENA, CHANNELING 2008, 2010, 30 : 696 - 704
  • [32] Intense quasi-monochromatic flash x-ray generator utilizing molybdenum-target diode
    Sagae, M
    Sato, E
    Obara, H
    Tanaka, E
    Mori, H
    Kawai, T
    Sato, S
    Ojima, H
    Takayama, K
    Ido, H
    26th International Congress on High Speed Photography and Photonics, 2005, 5580 : 674 - 680
  • [33] A compact pressure-insulated electrostatic x-ray generator
    Trump, JG
    van de Graaff, RJ
    PHYSICAL REVIEW, 1939, 55 (12): : 1160 - 1165
  • [34] A NEW COMPACT HIGH POWERED ANALYTICAL X-RAY GENERATOR
    ROSS, JA
    APPLIED SPECTROSCOPY, 1968, 22 (03) : 238 - &
  • [35] Lattice of NSCKIPT compact intense x-ray generator NESTOR
    Gladkikh, P
    Ivashchernko, V
    Karnaukhov, I
    Markov, V
    Mytsykov, A
    Shcherbakov, A
    Skyrda, V
    Trotsenko, V
    Zelinsky, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 543 (01): : 65 - 73
  • [36] A pulsed compact low-background X-ray generator
    Giomataris, I
    Belloni, F.
    Iguaz, F. J.
    Mols, J. P.
    Papaevangelou, T.
    Segui, L.
    JOURNAL OF COSMOLOGY AND ASTROPARTICLE PHYSICS, 2020, (12):
  • [37] PERFORMANCE OF RHODIUM TARGET TUBE IN X-RAY QUANTOMETERS
    DRYER, HT
    ANDERSON, CA
    DAVIDSON, E
    APPLIED SPECTROSCOPY, 1968, 22 (04) : 378 - &
  • [38] DESIGN OF MERCURY VAPOR TARGET X-RAY TUBE
    BEARDEN, JA
    HUFFMAN, FN
    SPIJKERM.JJ
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1964, 35 (12): : 1681 - &
  • [39] Comparative Analysis of Resonant Converters for X-Ray Generator Tube
    Bhuvaneswari, C.
    Memala, W. Abitha
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES, 2022, 65 (06) : 949 - 956
  • [40] Comparative Analysis of Resonant Converters for X-Ray Generator Tube
    C. Bhuvaneswari
    W. Abitha Memala
    Instruments and Experimental Techniques, 2022, 65 : 949 - 956