Compact x-ray generator utilizing cerium-target tube for angiography

被引:0
|
作者
Sato, E [1 ]
Tanaka, E [1 ]
Mori, H [1 ]
Kawai, T [1 ]
Ito, F [1 ]
Ichimaru, T [1 ]
Sato, S [1 ]
Takayama, K [1 ]
Ido, H [1 ]
机构
[1] Iwate Med Univ, Dept Phys, Morioka, Iwate 0200015, Japan
来源
X-RAY SOURCES AND OPTICS | 2004年 / 5537卷
关键词
x-ray tube; cerium target; quasi-monochromatic x rays; characteristic x rays; K-edge angiography;
D O I
10.1117/12.560534
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The cerium-target x-ray tube is useful in order to perform cone beam K-edge angiography because K-series characteristic x rays from the cerium target are absorbed effectively by iodine-based contrast mediums. The x-ray generator consists of a main controller and a unit with a high-voltage circuit and a fixed anode x-ray tube. The tube is a glass-enclosed diode with a cerium target and a 0.5 mm-thick beryllium window. The maximum tube voltage and current were 65 kV and 0.4 mA, respectively, and the focal-spot sizes were 1.3x0.9 mm. Cerium K-series characteristic x rays were left using a 3.0 mm-thick aluminum filter, and the x-ray intensity was 0.59 muC/kg at 1.0 m from the source with a tube voltage of 60 kV, a current of 0.40 mA, and an exposure time of 1.0 s. Angiography was performed with a computed radiography system using iodine-based microspheres 15 mum in diameter. In angiography of non-living animals, we observed fine blood vessels of approximately 100 mum with high contrasts.
引用
收藏
页码:75 / 81
页数:7
相关论文
共 50 条
  • [21] Characteristic X-ray generator utilizing angle dependence of bremsstrahlung X-ray distribution
    Sato, Eiichi
    Tanaka, Etsuro
    Mori, Hidezo
    Kawai, Toshiaki
    Inoue, Takashi
    Ogawa, Akira
    Sato, Shigehiro
    Takayama, Kazuyoshi
    Onagawa, Jun
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 2006, 45 (4 A): : 2845 - 2849
  • [22] Characteristic X-ray generator utilizing angle dependence of bremsstrahlung X-ray distribution
    Sato, E
    Tanaka, E
    Mori, H
    Kawai, T
    Inoue, T
    Ogawa, A
    Sato, S
    Takayama, K
    Onagawa, J
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2006, 45 (4A): : 2845 - 2849
  • [23] Compact high current generator for x-ray radiography
    Kharlov, A. V.
    Kovalchuk, B. M.
    Zorin, V. B.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2006, 77 (12):
  • [24] A compact nanosecond pulse generator for x-ray radiographies
    Zhou, Lin
    Ye, Mingtian
    Qi, Jianming
    Chu, Yanyun
    Wang, Zhen
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2021, 92 (12):
  • [25] AN X-RAY TUBE TARGET CURRENT STABILIZER
    CRISP, RS
    JOURNAL OF SCIENTIFIC INSTRUMENTS, 1958, 35 (12): : 470 - 471
  • [26] X-ray spectra from a cerium target and their application to cone beam K-edge angiography
    Sato, M
    Yamadera, A
    Tanaka, E
    Mori, H
    Kawai, T
    Ito, F
    Inoue, T
    Ogawa, A
    Sato, S
    Takayama, K
    Onagawa, J
    Ido, H
    OPTICAL ENGINEERING, 2005, 44 (09)
  • [27] Quasi-monochromatic flash X-ray generator utilizing disk-cathode molybdenum tube
    Sato, E
    Sagae, M
    Tanaka, E
    Hayasi, Y
    Germer, R
    Mori, H
    Kawai, T
    Ichimaru, T
    Sato, S
    Takayama, K
    Ido, H
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS BRIEF COMMUNICATIONS & REVIEW PAPERS, 2004, 43 (10): : 7324 - 7328
  • [28] Quasi-monochromatic flash X-ray generator utilizing disk-cathode molybdenum tube
    Sato, E., 1600, Japan Society of Applied Physics (43):
  • [29] On angiography with a Thomson laser-electron X-ray generator
    Vinogradov, A. V.
    Vinogradov, S. L.
    D'yachkov, N. V.
    Polunina, A. V.
    Postnov, A. A.
    QUANTUM ELECTRONICS, 2017, 47 (01) : 75 - 78
  • [30] A COMPACT HIGH-POWER X-RAY TUBE FOR FLUORESCENT X-RAY SPECTRAL ANALYSIS
    SOBOLEVS.GD
    IOFFE, YK
    NIKOLAEN.GM
    FRIDMAN, EM
    INDUSTRIAL LABORATORY, 1965, 31 (11): : 1766 - &