Investigation of the Static and Dynamic Musculotendinous Architecture of Supraspinatus

被引:41
|
作者
Kim, S. [1 ]
Bleakney, R. [2 ,3 ]
Boynton, E. [4 ]
Ravichandiran, K. [1 ]
Rindlisbacher, T. [5 ,6 ]
McKee, N. [7 ]
Agur, A. [1 ]
机构
[1] Univ Toronto, Dept Surg, Div Anat, Toronto, ON, Canada
[2] Mt Sinai Hosp, Univ Hlth Network, Joint Dept Med Imaging, Musculoskeletal Div, Toronto, ON M5G 1X5, Canada
[3] Univ Toronto, Womens Coll Hosp, Toronto, ON, Canada
[4] Inst Sports Med, Toronto, ON, Canada
[5] Cleveland Clin Canada, Toronto, ON, Canada
[6] Univ Toronto, Sunnybrook Hlth Sci Ctr, Toronto, ON, Canada
[7] Univ Toronto, Dept Surg, Div Plast & Reconstruct Surg, Toronto, ON, Canada
关键词
rotator cuff; shoulder; muscle; tendon; fiber bundle; angle; exercises; surgery; INTRATENDINOUS STRAIN FIELDS; SKELETAL-MUSCLE ARCHITECTURE; ROTATOR CUFF; IN-VIVO; THICKNESS; TENDON; PENNATION; TEARS;
D O I
10.1002/ca.20896
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
To date, the architecture of supraspinatus (SP) and its relation to joint position has not been investigated. The purpose of this study was to quantify the dynamic architecture of the distinct regions of SP using ultrasound (US). Seventeen subjects (8 M/9 F), mean age 36.4 +/- 12.7 years, without tendon pathology were recruited. The SP was scanned in relaxed and contracted states. For the contracted state, SP was scanned with the shoulder actively abducted to 60 degrees and the glenohumeral joint in neutral rotation; 80 degrees external rotation; 80 degrees internal rotation. Fiber bundle length (FBL) and pennation angle (PA) of distinct regions, and muscle thickness were computed. Measurements of the posterior region were limited because of acromion shadowing. Parameters between regions and changes between relaxed and contracted states were analyzed using paired t-tests and repeated measures ANOVA (P < 0.05). On contraction in the anterior region, mean percentage of FBL shortening ranged between 9% and 21%. However, in the posterior region, shortening of approximately 2% only occurred in two of the three positions; lengthening of approximately 2.5% occurred in internal rotation. For the anterior region, the mean PA increased the least in the externally rotated position, and the mean PA of the middle part was smaller than the deep part for all states. Findings suggest changes in the architecture are not uniform throughout the muscle and joint position may play an important role in force production. The US protocol may serve as an outcome measure of adaptive changes of muscle function following surgery, training, and rehabilitation. Clin. Anat. 23:48-55, 2010. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:48 / 55
页数:8
相关论文
共 50 条
  • [31] Investigation of static and dynamic bulk moduli in a carbonate field
    Sharifi, Javad
    Saberi, Mohammad Reza
    Javaherian, Abdolrahim
    Hafezi Moghaddas, Naser
    EXPLORATION GEOPHYSICS, 2021, 52 (01) : 16 - 41
  • [32] Investigation of fracture of spheroplastics under static and dynamic loading
    Atroshenko S.A.
    Krivosheev S.I.
    Petrov Y.A.
    Utkin A.A.
    Fedorovskii G.D.
    Strength of Materials, 2002, 34 (3) : 273 - 276
  • [33] Sonographic anatomy and dynamic study of the normal iliopsoas musculotendinous junction
    Raphaël Guillin
    Étienne Cardinal
    Nathalie J. Bureau
    European Radiology, 2009, 19 : 995 - 1001
  • [34] DYNAMIC MUSCULOTENDINOUS TRANSFER TO REPLACE THE ANTERIOR CRUCIATE LIGAMENT IN THE DOG
    ADELAAR, RS
    ZUELZER, W
    ANTHONY, S
    CARDEA, JA
    LURIE, HI
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1983, 65 (05): : 650 - 655
  • [35] Revealing static and dynamic modular architecture of the eukaryotic protein interaction network
    Komurov, Kakajan
    White, Michael
    MOLECULAR SYSTEMS BIOLOGY, 2007, 3 (1) : 1 - 11
  • [36] Maintenance of service oriented architecture composite applications: static and dynamic support
    White, Laura J.
    Reichherzer, Thomas
    Coffey, John
    Wilde, Norman
    Simmons, Sharon
    JOURNAL OF SOFTWARE-EVOLUTION AND PROCESS, 2013, 25 (01) : 97 - 109
  • [37] Static vs Dynamic Architecture of Aware Cyber Physical Systems of Systems
    Bemus, Peter
    Noran, Ovidiu
    2021 IEEE 25TH INTERNATIONAL ENTERPRISE DISTRIBUTED OBJECT COMPUTING CONFERENCE WORKSHOPS (EDOCW 2021), 2021, : 186 - 193
  • [38] Static IRS Meets Distributed MIMO: A New Architecture for Dynamic Beamforming
    Chen, Guangji
    Wu, Qingqing
    Wu, Celimuge
    Jian, Mengnan
    Chen, Yijian
    Chen, Wen
    IEEE WIRELESS COMMUNICATIONS LETTERS, 2023, 12 (11) : 1866 - 1870
  • [39] An amalgamated dynamic and static architecture reconstruction framework to control component interactions
    Sartipi, Kamran
    Dezhkam, Nima
    14TH WORKING CONFERENCE ON REVERSE ENGINEERING, PROCEEDINGS, 2007, : 259 - 268
  • [40] A hierarchical birdsong feature extraction architecture combining static and dynamic modeling
    Wang, Yanan
    Chen, Aibin
    Li, Huaicheng
    Zhou, Guoxiong
    Yi, Jizheng
    Zhang, Zhiqiang
    ECOLOGICAL INDICATORS, 2023, 150