Investigation of the Static and Dynamic Musculotendinous Architecture of Supraspinatus

被引:41
|
作者
Kim, S. [1 ]
Bleakney, R. [2 ,3 ]
Boynton, E. [4 ]
Ravichandiran, K. [1 ]
Rindlisbacher, T. [5 ,6 ]
McKee, N. [7 ]
Agur, A. [1 ]
机构
[1] Univ Toronto, Dept Surg, Div Anat, Toronto, ON, Canada
[2] Mt Sinai Hosp, Univ Hlth Network, Joint Dept Med Imaging, Musculoskeletal Div, Toronto, ON M5G 1X5, Canada
[3] Univ Toronto, Womens Coll Hosp, Toronto, ON, Canada
[4] Inst Sports Med, Toronto, ON, Canada
[5] Cleveland Clin Canada, Toronto, ON, Canada
[6] Univ Toronto, Sunnybrook Hlth Sci Ctr, Toronto, ON, Canada
[7] Univ Toronto, Dept Surg, Div Plast & Reconstruct Surg, Toronto, ON, Canada
关键词
rotator cuff; shoulder; muscle; tendon; fiber bundle; angle; exercises; surgery; INTRATENDINOUS STRAIN FIELDS; SKELETAL-MUSCLE ARCHITECTURE; ROTATOR CUFF; IN-VIVO; THICKNESS; TENDON; PENNATION; TEARS;
D O I
10.1002/ca.20896
中图分类号
R602 [外科病理学、解剖学]; R32 [人体形态学];
学科分类号
100101 ;
摘要
To date, the architecture of supraspinatus (SP) and its relation to joint position has not been investigated. The purpose of this study was to quantify the dynamic architecture of the distinct regions of SP using ultrasound (US). Seventeen subjects (8 M/9 F), mean age 36.4 +/- 12.7 years, without tendon pathology were recruited. The SP was scanned in relaxed and contracted states. For the contracted state, SP was scanned with the shoulder actively abducted to 60 degrees and the glenohumeral joint in neutral rotation; 80 degrees external rotation; 80 degrees internal rotation. Fiber bundle length (FBL) and pennation angle (PA) of distinct regions, and muscle thickness were computed. Measurements of the posterior region were limited because of acromion shadowing. Parameters between regions and changes between relaxed and contracted states were analyzed using paired t-tests and repeated measures ANOVA (P < 0.05). On contraction in the anterior region, mean percentage of FBL shortening ranged between 9% and 21%. However, in the posterior region, shortening of approximately 2% only occurred in two of the three positions; lengthening of approximately 2.5% occurred in internal rotation. For the anterior region, the mean PA increased the least in the externally rotated position, and the mean PA of the middle part was smaller than the deep part for all states. Findings suggest changes in the architecture are not uniform throughout the muscle and joint position may play an important role in force production. The US protocol may serve as an outcome measure of adaptive changes of muscle function following surgery, training, and rehabilitation. Clin. Anat. 23:48-55, 2010. (C) 2009 Wiley-Liss, Inc.
引用
收藏
页码:48 / 55
页数:8
相关论文
共 50 条
  • [21] Distributed Software Architecture for AGVs for Separation of Dynamic and Static Obstacles
    Scholz, Michael
    Lieret, Markus
    Bigott, Marc
    Franke, Joerg
    29TH INTERNATIONAL CONFERENCE ON FLEXIBLE AUTOMATION AND INTELLIGENT MANUFACTURING (FAIM 2019): BEYOND INDUSTRY 4.0: INDUSTRIAL ADVANCES, ENGINEERING EDUCATION AND INTELLIGENT MANUFACTURING, 2019, 38 : 367 - 374
  • [22] VXI architecture provides integration of static/dynamic testing solution
    McDonald, DJ
    PROCEEDINGS OF IMAC-XIX: A CONFERENCE ON STRUCTURAL DYNAMICS, VOLS 1 AND 2, 2001, 4359 : 27 - 31
  • [23] Branched architecture of fucoidan characterized by dynamic and static light scattering
    Ekaterina R. Gasilova
    Irina M. Lapina
    Anna A. Kulminskaya
    Yury A. Skorik
    Colloid and Polymer Science, 2020, 298 : 1349 - 1359
  • [24] Branched architecture of fucoidan characterized by dynamic and static light scattering
    Gasilova, Ekaterina R.
    Lapina, Irina M.
    Kulminskaya, Anna A.
    Skorik, Yury A.
    COLLOID AND POLYMER SCIENCE, 2020, 298 (10) : 1349 - 1359
  • [25] Investigation of Static and Dynamic Stability of the Deformable Dynamic Spiral Magnetic Domain
    V. N. Mal’tsev
    A. A. Nesterenko
    The Physics of Metals and Metallography, 2016, 117 : 222 - 229
  • [26] Investigation of Static and Dynamic Stability of the Deformable Dynamic Spiral Magnetic Domain
    Mal'tsev, V. N.
    Nesterenko, A. A.
    PHYSICS OF METALS AND METALLOGRAPHY, 2016, 117 (03): : 222 - 229
  • [27] Passive tension in the supraspinatus musculotendinous unit after long-standing rupture of its tendon: A preliminary report
    Hersche, O
    Gerber, C
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 1998, 7 (04) : 393 - 396
  • [28] Effects of a static stretching program on the incidence of lower extremity musculotendinous strains
    Cross, KM
    Worrell, TW
    JOURNAL OF ATHLETIC TRAINING, 1999, 34 (01) : 11 - 14
  • [29] EXPERIMENTAL INVESTIGATION INTO THE STATIC AND DYNAMIC STIFFNESS OF A MACHINING CENTER
    BLINOV, VB
    SOVIET ENGINEERING RESEARCH, 1986, 6 (12): : 57 - 59
  • [30] An Experimental Investigation on Static and Dynamic Fracture Properties of MgAl
    Zhong, Weizhou
    Luo, Jingrun
    Song, Shuncheng
    Huang, Xicheng
    MANUFACTURING SCIENCE AND ENGINEERING, PTS 1-5, 2010, 97-101 : 683 - +