Electron beam quality correction factors for plane-parallel ionization chambers: Monte Carlo calculations using the PENELOPE system

被引:96
|
作者
Sempau, J [1 ]
Andreo, P
Aldana, J
Mazurier, J
Salvat, F
机构
[1] Univ Politecn Cataluna, Inst Tecn Energet, Barcelona, Spain
[2] Stockholm Univ, Karolinska Inst, S-10691 Stockholm, Sweden
[3] Ctr Hautes Energies, Serv Radiotherapie, Toulouse, France
[4] Univ Barcelona, Fac Fis, ECM, E-08028 Barcelona, Spain
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2004年 / 49卷 / 18期
关键词
D O I
10.1088/0031-9155/49/18/016
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Simulations of three plane-parallel ionization chambers have been used to determine directly the chamber-and quality-dependent factors fc,(Q,) instead of the product (S-w,(air) p)(Q), and k(Q).(Q), (or k(Q),(Qint)) for a broad range of electron beam qualities (4-20 MeV) using divergent monoenergetic beams and phase-space data from two accelerators. An original calculation method has been used which circumvents the weakness of the so far assumed independence between stopping-power ratios and perturbation factors. Very detailed descriptions of the geometry and materials of the chambers have been obtained from the manufacturers, and prepared as input to the PENELOPE 2003 Monte Carlo system using a computer code that includes correlated sampling and particle splitting. Values of the beam quality factors have been determined for the case of an electron reference beam. The calculated values have been compared with those in the IAEA TRS-398 dosimetry protocol and the differences analysed. The results for a NACP-02 chamber show remarkably good agreement with TRS-398 at high electron beam qualities but differ slightly at low energies. Arguments to explain the differences include questioning the undemonstrated assumption that the NACP is a 'perturbation-free' chamber even at very low electron beam energies. Results for Wellhofer PPC-40 and PPC-05 chambers cannot be compared with data from others for these chambers because no calculations or reliable experimental data exist. It has been found that the results for the PPC-40 are very close to those of a Roos chamber, but the values for the PPC-05 are considerably different from those of a Markus chamber, and rather approach those of a Roos chamber. Results for monoenergetic electrons and accelerator phase-space data have been compared to assess the need for detailed and costly simulations, finding very small differences. This questions the emphasis given in recent years to the use of 'realistic' source data for accurate electron beam dosimetry.
引用
收藏
页码:4427 / 4444
页数:18
相关论文
共 50 条
  • [41] CALIBRATION AND USE OF PLANE-PARALLEL IONIZATION CHAMBERS FOR THE DETERMINATION OF ABSORBED DOSE IN ELECTRON-BEAMS
    MATTSSON, LO
    JOHANSSON, KA
    SVENSSON, H
    ACTA RADIOLOGICA ONCOLOGY, 1981, 20 (06): : 385 - 399
  • [42] Determination of the recombination correction factor kS for some specific plane-parallel and cylindrical ionization chambers in pulsed photon and electron beams
    Bruggmoser, G.
    Saum, R.
    Schmachtenberg, A.
    Schmid, F.
    Schuele, E.
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (02): : N35 - N50
  • [43] Monte Carlo calculations of the perturbation correction factors for a parallel plate Roos chamber in electron beams
    Zink, K.
    Wulff, J.
    RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S113 - S113
  • [44] Monte Carlo calculations of correction factors for plastic phantoms in clinical photon and electron beam dosimetry
    Araki, Fujio
    Hanyu, Yuji
    Fukuoka, Miyoko
    Matsumoto, Kenji
    Okumura, Masahiko
    Oguchi, Hiroshi
    MEDICAL PHYSICS, 2009, 36 (07) : 2992 - 3001
  • [45] Monte Carlo calculated beam quality correction factors for high energy electron beams
    Alissa, Mohamad
    Zink, Klemens
    Roeser, Arnd
    Flatten, Veronika
    Schoenfeld, Andreas A.
    Czarnecki, Damian
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2024, 117
  • [46] Monte Carlo simulation of initial and volume ion recombination correction factor in plane parallel ionization chambers exposed to ion beams
    Orts, Marina
    Rossomme, Severine
    Souris, Kevin
    Sterpin, Edmond
    PHYSICS IN MEDICINE AND BIOLOGY, 2024, 69 (16):
  • [47] Monte Carlo calculations of beam quality correction factors for monoenergetic carbon-ion beams
    Stolzenberg, Jessica
    Sasse, Pascal
    Baumann, Kilian
    Poppe, Bjoern
    Looe, Hui Khee
    RADIOTHERAPY AND ONCOLOGY, 2024, 194 : S3314 - S3316
  • [48] Experimental investigation of the effective point of measurement for plane-parallel chambers used in electron beam dosimetry
    Yasui, Kohki
    Nakajima, Yujiro
    Suda, Yuhi
    Arai, Yu
    Takizawa, Takuto
    Sakai, Kaito
    Fujita, Yukio
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2023, 24 (07):
  • [50] Monte Carlo simulated beam quality and perturbation correction factors for ionization chambers in monoenergetic proton beams (vol 47, pg 5890, 2020)
    Kretschmer, J.
    Dulkys, A.
    Brodbek, L.
    MEDICAL PHYSICS, 2021,