Variation of intra-access flow early and late into hemodialysis

被引:18
|
作者
Agharazii, M [1 ]
Clouâtre, Y [1 ]
Nolin, L [1 ]
Leblanc, M [1 ]
机构
[1] Univ Montreal, Hop Maison Neuve Rosemont, Dept Nephrol, Hemodialysis Unit, Montreal, PQ H1T 2M4, Canada
关键词
D O I
10.1097/00002480-200007000-00017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Intra-access flow (Qac), measured by ultrasound dilution, is a reliable method for screening for access dysfunction. Because of a reduced circulating volume and a relative decrease in blood pressure at the end of hemodialysis (HD), we hypothesized that Qac could be significantly reduced when measured late into HD. Fifty patients were prospectively evaluated for variation in Qac early and late into HD. There were 33 native fistulae and 17 synthetic grafts. Six separate measures of Qac were performed for each patient by ultrasound dilution (Transonic HD01 hemodialysis monitor; Transonic Systems, Inc., Ithaca, NY): three within the first 30 minutes and three within the last 30 minutes of HD. Session time was 3.5 or 4 hours, and mean net ultrafiltration was 3.3 +/- 0.9 L/HD. Early and late into HD, mean arterial pressure (MAP) decreased from 100.0 +/- 14.6 to 92.8 +/- 17.8 mm Hg, heart rate from 73 +/- 11 to 79 +/- 15 bpm, and hematocrit: increased from 34 +/- 3 to 38 +/- 4%. For the whole group, mean Qac decreased from 1,101.7 +/- 566.7 to 972.5 +/- 515.6 ml/min (p = NS); when Qac was corrected for a MAP of 100 mm Hg, the reduction remained nonsignificant (from 1,101.7 to 1,048.0 ml/min). When considering native and synthetic fistulae separately, the drop in Qac was still nonsignificant (from 1,098.9 +/- 613.4 to 983.2 +/- 593.2 for native fistulae versus 1,107.2 +/- 480.5 to 999.8 +/- 379.8 ml/min for grafts, p = NS). Overall, the percent reduction in Qac early versus late into HD was 11.7%, whereas it reached only 4.9% when access flows corrected for MAP were considered. We conclude that variation in Qac during HD is relatively small, especially when values are corrected for MAP. Therefore, according to our results, Qac measures by using the ultrasound dilution method made at any time during HD should be reliable for most patients.
引用
收藏
页码:452 / 455
页数:4
相关论文
共 50 条
  • [31] Hemodialysis access flow phantom
    Smits, HFM
    Bos, C
    van der Weide, R
    Bakker, CJG
    JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1998, 9 (05) : 840 - 845
  • [32] Performance Analysis of the 802.11aa Intra-Access Category Prioritization under Saturated Condition
    Zeng, Yijing
    2014 IEEE GLOBAL COMMUNICATIONS CONFERENCE (GLOBECOM 2014), 2014, : 4610 - 4615
  • [33] Patency rates and intra-access blood flow (Qa) when using the angioflow catheter (AC) to verify arteriovenous dialysis vascular access percutaneous angioplasty success.
    Levine, MI
    Anne, RE
    Jeffrey, WD
    Matthew, HH
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2003, 14 : 724A - 724A
  • [34] The StenTec Gauge for Measuring Static Intra-access Pressure Ratio (PIa Ratio) of Fistulas and Grafts
    Ash, Stephen R.
    Dhamija, Rajiv
    Zaroura, Mohamad Y.
    Hentschel, Dirk M.
    SEMINARS IN DIALYSIS, 2012, 25 (04) : 474 - 481
  • [35] UTILITY OF INTRA-ACCESS PRESSURE MONITORING IN DETECTING AND CORRECTING VENOUS OUTLET STENOSES PRIOR TO THROMBOSIS
    BESARAB, A
    SULLIVAN, KL
    ROSS, RP
    MORITZ, MJ
    KIDNEY INTERNATIONAL, 1995, 47 (05) : 1364 - 1373
  • [36] Multi-user access mechanism with intra-access categories differentiation for IEEE 802.11ac wireless local area networks
    Charfi, Emna
    Chaari, Lamia
    Ben Hlima, Souha
    Kammoun, Lotfi
    TELECOMMUNICATION SYSTEMS, 2017, 64 (03) : 479 - 494
  • [37] Access flow measured during hemodialysis
    Sands, J
    Glidden, D
    Miranda, C
    ASAIO JOURNAL, 1996, 42 (05) : M530 - M532
  • [38] Access flow measured during hemodialysis
    Department of Wyoming Valley, P.C., Wilkes-Barre, PA, United States
    不详
    不详
    ASAIO J., 5 (M530-M532):
  • [39] Hemodialysis Access Flow Measurements Using Flow Dilution and In-Line Dialysance Are Not Interchangeable for Hemodialysis Access Flow Surveillance Response
    Mansy, Hansen A.
    Whittier, William L.
    Sandler, Richard H.
    ASAIO JOURNAL, 2010, 56 (01) : 80 - 80
  • [40] Multi-user access mechanism with intra-access categories differentiation for IEEE 802.11ac wireless local area networks
    Emna Charfi
    Lamia Chaari
    Souha Ben Hlima
    Lotfi Kammoun
    Telecommunication Systems, 2017, 64 : 479 - 494