Variation of intra-access flow early and late into hemodialysis

被引:18
|
作者
Agharazii, M [1 ]
Clouâtre, Y [1 ]
Nolin, L [1 ]
Leblanc, M [1 ]
机构
[1] Univ Montreal, Hop Maison Neuve Rosemont, Dept Nephrol, Hemodialysis Unit, Montreal, PQ H1T 2M4, Canada
关键词
D O I
10.1097/00002480-200007000-00017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Intra-access flow (Qac), measured by ultrasound dilution, is a reliable method for screening for access dysfunction. Because of a reduced circulating volume and a relative decrease in blood pressure at the end of hemodialysis (HD), we hypothesized that Qac could be significantly reduced when measured late into HD. Fifty patients were prospectively evaluated for variation in Qac early and late into HD. There were 33 native fistulae and 17 synthetic grafts. Six separate measures of Qac were performed for each patient by ultrasound dilution (Transonic HD01 hemodialysis monitor; Transonic Systems, Inc., Ithaca, NY): three within the first 30 minutes and three within the last 30 minutes of HD. Session time was 3.5 or 4 hours, and mean net ultrafiltration was 3.3 +/- 0.9 L/HD. Early and late into HD, mean arterial pressure (MAP) decreased from 100.0 +/- 14.6 to 92.8 +/- 17.8 mm Hg, heart rate from 73 +/- 11 to 79 +/- 15 bpm, and hematocrit: increased from 34 +/- 3 to 38 +/- 4%. For the whole group, mean Qac decreased from 1,101.7 +/- 566.7 to 972.5 +/- 515.6 ml/min (p = NS); when Qac was corrected for a MAP of 100 mm Hg, the reduction remained nonsignificant (from 1,101.7 to 1,048.0 ml/min). When considering native and synthetic fistulae separately, the drop in Qac was still nonsignificant (from 1,098.9 +/- 613.4 to 983.2 +/- 593.2 for native fistulae versus 1,107.2 +/- 480.5 to 999.8 +/- 379.8 ml/min for grafts, p = NS). Overall, the percent reduction in Qac early versus late into HD was 11.7%, whereas it reached only 4.9% when access flows corrected for MAP were considered. We conclude that variation in Qac during HD is relatively small, especially when values are corrected for MAP. Therefore, according to our results, Qac measures by using the ultrasound dilution method made at any time during HD should be reliable for most patients.
引用
收藏
页码:452 / 455
页数:4
相关论文
共 50 条
  • [21] Native arteriovenous fistulas: Correlation of intra-access blood flow with characteristics of stenoses found during diagnostic angiography
    Monroy-Cuadros, Mauricio
    Salazar, Anastasio
    Yilmaz, Serdar
    McLaughlin, Kevin
    SEMINARS IN DIALYSIS, 2008, 21 (01) : 89 - 92
  • [22] Static intra-access pressure ratio and cardiovascular events in patients undergoing haemodialysis
    Hee Jung Jeon
    Jieun Oh
    Young-Ki Lee
    Ajin Cho
    Jong Woo Yoon
    Hyunsuk Kim
    Dong Ho Shin
    Scientific Reports, 10
  • [23] Dialyzer venous drip chamber (DC) accurately reflects intra-access pressure
    Besarab, A
    Frinak, S
    Dumler, F
    Goldman, J
    DeVita, MV
    Sherman, R
    Kapoian, T
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1996, 7 (09): : A0786 - A0786
  • [24] Static intra-access pressure ratio and cardiovascular events in patients undergoing haemodialysis
    Jeon, Hee Jung
    Oh, Jieun
    Lee, Young-Ki
    Cho, Ajin
    Yoon, Jong Woo
    Kim, Hyunsuk
    Shin, Dong Ho
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [25] The accuracy of drip chamber method in measuring static intra-access pressure: Comparison with Access Alert method
    Kim, Young Ok
    Shin, Young Shin
    Shin, Mi Jung
    Song, Ho Cheol
    Yoon, Sun Ae
    Lee, Seung Hun
    Kim, Yong Soo
    Kim, Suk Young
    Choi, Euy Jin
    Chang, Yoon Sik
    Bang, Byung Kee
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2006, 21 : 218 - 218
  • [27] PREDICTION OF VASCULAR ACCESS STENOSIS: BLOOD TEMPERATURE MONITORING WITH TWISTER VS STATIC INTRA-ACCESS PRESSURE RATIO
    Choi, Yoo Jin
    Lee, Young-Ki
    Cho, Ajin
    Kim, Eun Yi
    Choi, Sun Ryoung
    Kim, Eun-Jung
    Yoon, Jong-Woo
    Noh, Jung-Woo
    NEPHROLOGY DIALYSIS TRANSPLANTATION, 2018, 33 : 233 - 233
  • [28] Prediction of vascular access stenosis: Blood temperature monitoring with the Twister versus static intra-access pressure ratio
    Choi, Yoo Jin
    Lee, Young-Ki
    Park, Hayne Cho
    Kim, Eun Yi
    Cho, Ajin
    Han, Chaehoon
    Choi, Sun Ryoung
    Kim, Hanmyun
    Kim, Eun-Jung
    Yoon, Jong-Woo
    Noh, Jung-Woo
    PLOS ONE, 2018, 13 (10):
  • [29] The consistency of intra-access pressure (IAP) measured using an external pressure transducer.
    Kapoian, T
    Steward, CA
    Sherman, RA
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1997, 8 : A0761 - A0761
  • [30] Total short-term variation in hemodialysis access blood flow: Implications for access monitoring.
    Sharaf, R
    Ram, SJ
    Swamy, S
    Magnasco, A
    Abreo, K
    Zsom, L
    Paulson, WD
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2003, 14 : 721A - 721A