Variation of intra-access flow early and late into hemodialysis

被引:18
|
作者
Agharazii, M [1 ]
Clouâtre, Y [1 ]
Nolin, L [1 ]
Leblanc, M [1 ]
机构
[1] Univ Montreal, Hop Maison Neuve Rosemont, Dept Nephrol, Hemodialysis Unit, Montreal, PQ H1T 2M4, Canada
关键词
D O I
10.1097/00002480-200007000-00017
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Intra-access flow (Qac), measured by ultrasound dilution, is a reliable method for screening for access dysfunction. Because of a reduced circulating volume and a relative decrease in blood pressure at the end of hemodialysis (HD), we hypothesized that Qac could be significantly reduced when measured late into HD. Fifty patients were prospectively evaluated for variation in Qac early and late into HD. There were 33 native fistulae and 17 synthetic grafts. Six separate measures of Qac were performed for each patient by ultrasound dilution (Transonic HD01 hemodialysis monitor; Transonic Systems, Inc., Ithaca, NY): three within the first 30 minutes and three within the last 30 minutes of HD. Session time was 3.5 or 4 hours, and mean net ultrafiltration was 3.3 +/- 0.9 L/HD. Early and late into HD, mean arterial pressure (MAP) decreased from 100.0 +/- 14.6 to 92.8 +/- 17.8 mm Hg, heart rate from 73 +/- 11 to 79 +/- 15 bpm, and hematocrit: increased from 34 +/- 3 to 38 +/- 4%. For the whole group, mean Qac decreased from 1,101.7 +/- 566.7 to 972.5 +/- 515.6 ml/min (p = NS); when Qac was corrected for a MAP of 100 mm Hg, the reduction remained nonsignificant (from 1,101.7 to 1,048.0 ml/min). When considering native and synthetic fistulae separately, the drop in Qac was still nonsignificant (from 1,098.9 +/- 613.4 to 983.2 +/- 593.2 for native fistulae versus 1,107.2 +/- 480.5 to 999.8 +/- 379.8 ml/min for grafts, p = NS). Overall, the percent reduction in Qac early versus late into HD was 11.7%, whereas it reached only 4.9% when access flows corrected for MAP were considered. We conclude that variation in Qac during HD is relatively small, especially when values are corrected for MAP. Therefore, according to our results, Qac measures by using the ultrasound dilution method made at any time during HD should be reliable for most patients.
引用
收藏
页码:452 / 455
页数:4
相关论文
共 50 条
  • [1] THE RELATION OF INTRA-ACCESS PRESSURE TO INTRA-ACCESS FLOW
    BESARAB, A
    ROSS, R
    ELAJEL, F
    DEANE, C
    FRINAK, S
    ZASUWA, G
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1995, 6 (03): : 483 - 483
  • [2] The effect of vascular access type on intra-access flow volume during hemodialysis
    Park, Hoon Suk
    Kim, Woo Jeong
    Choi, Joonsung
    Kim, Hyung Wook
    Baik, Jun Hyun
    Kim, Young Ok
    Park, Cheol Whee
    Yang, Chul Woo
    Jin, Dong Chan
    JOURNAL OF VASCULAR ACCESS, 2019, 20 (06): : 746 - 751
  • [3] Intervention for intra-access stenosis
    Besarab, A
    SEMINARS IN DIALYSIS, 2001, 14 (05) : 401 - 402
  • [4] Utility of intra-access pressure
    Caro, P
    Delgado, R
    Dapena, F
    Aguilera, A
    NEFROLOGIA, 2004, 24 (04): : 357 - 363
  • [5] Static intra-access pressure ratio does not correlate with access blood flow
    Spergel, LM
    Holland, JE
    Fadem, SZ
    McAllister, CJ
    Peacock, EJ
    KIDNEY INTERNATIONAL, 2004, 66 (04) : 1512 - 1516
  • [6] Simplified measurement of intra-access pressure
    Besarab, A
    Frinak, S
    Sherman, RA
    Goldman, J
    Dumler, F
    Devita, MV
    Kapoian, T
    Al-Saghir, F
    Lubkowski, T
    JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 1998, 9 (02): : 284 - 289
  • [7] Accuracy of physical examination and intra-access pressure in the detection of stenosis in hemodialysis arteriovenous fistula
    Campos, Rodrigo Peixoto
    Chula, Domingos Candiota
    Perreto, Sonia
    Riella, Miguel Carlos
    do Nascimento, Marcelo Mazza
    SEMINARS IN DIALYSIS, 2008, 21 (03) : 269 - 273
  • [8] Simplified measurement of intra-access pressure
    Besarab, A
    AlSaghir, F
    Alnabhan, N
    Lubkowski, T
    Frinak, S
    ASAIO JOURNAL, 1996, 42 (05) : M682 - M687
  • [9] Simplified measurement of intra-access pressure
    Div. of Nephrology and Hypertension, Department of Medicine, Henry Ford Hospital, Detroit, MI, United States
    不详
    ASAIO J., 5 (M682-M687):
  • [10] Prospective evaluation of the intra-access flow of recently created native arteriovenous fistulae
    Begin, V
    Ethier, J
    Dumont, M
    Leblanc, M
    AMERICAN JOURNAL OF KIDNEY DISEASES, 2002, 40 (06) : 1277 - 1282