Overcoming artifacts from metallic orthopedic implants at high-field-strength MR imaging and multidetector CT

被引:379
|
作者
Lee, Mi-Jung
Kim, Sungjun
Lee, Sung-Ah
Song, Ho-Taek
Huh, Yong-Min
Kim, Dae-Hong
Han, Seung Hwan
Suh, Jin-Suck
机构
[1] Yonsei Univ, Coll Med, Dept Diagnost Radiol, Seoul 120752, South Korea
[2] Yonsei Univ, Coll Med, Res Inst Radiol Sci, Seoul 120752, South Korea
[3] Yonsei Univ, Coll Med, Brain Korea Project Med Sci 21, Seoul 120752, South Korea
[4] Hanyang Univ, Coll Med, Dept Diagnost Radiol, Kuri City, Kyunggi Do, South Korea
[5] Ajou Univ, Coll Med, Dept Orthoped Surg, Suwon 441749, South Korea
关键词
D O I
10.1148/rg.273065087
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
At magnetic resonance ( MR) imaging and multidetector computed tomography ( CT), artifacts arising from metallic orthopedic hardware are an obstacle to obtaining optimal images. Although various techniques for reducing such artifacts have been developed and corroborated by previous researchers, a new era of more powerful MR imaging and multidetector CT modalities has renewed the importance of a systematic consideration of methods for artifact reduction. Knowledge of the factors that contribute to artifacts, of related theories, and of artifact reduction techniques has become mandatory for radiologists. Factors that affect artifacts on MR images include the composition of the metallic hardware, the orientation of the hardware in relation to the direction of the main magnetic field, the strength of the magnetic field, the pulse sequence type, and other MR imaging parameters ( mainly voxel size, which is determined by the field of view, image matrix, section thickness, and echo train length). At multidetector CT, the factors that affect artifacts include the composition of the hardware, orientation of the hardware, acquisition parameters ( peak voltage, tube charge, collimation, and acquired section thickness), and reconstruction parameters ( reconstructed section thickness, reconstruction algorithm used, and whether an extended CT scale was used). A comparison of images obtained with different hardware and different acquisition and reconstruction parameters facilitates an understanding of methods for reducing or overcoming artifacts related to metallic implants. (C) RSNA, 2007.
引用
收藏
页码:791 / 803
页数:13
相关论文
共 50 条
  • [21] HIGH-FIELD-STRENGTH STIR IMAGING - LIMITATIONS - REPLY
    PORTER, BA
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1989, 153 (05) : 1104 - 1104
  • [22] ARTIFACTS FROM METALLIC ORTHOPEDIC IMPLANTS - CHARACTERIZATION DEPENDING ON IMAGING SEQUENCE, IMPLANT ORIENTATION, AND METAL TYPE
    MCDONNELL, CH
    GOLD, JS
    BJORKENGREN, AG
    HERFKENS, RJ
    RADIOLOGY, 1992, 185 : 117 - 117
  • [23] MR-GUIDED NEEDLE-BIOPSY WITH A HIGH-FIELD-STRENGTH MR SYSTEM
    LUFKIN, RB
    AMERICAN JOURNAL OF NEURORADIOLOGY, 1991, 12 (06) : 1268 - 1268
  • [24] Numerical approach to investigate MR imaging artifacts from orthopedic implants at different field strengths according to ASTM F2119
    Spronk, Tobias
    Kraff, Oliver
    Schaefers, Gregor
    Quick, Harald H.
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2023, 36 (05) : 725 - 735
  • [25] Numerical approach to investigate MR imaging artifacts from orthopedic implants at different field strengths according to ASTM F2119
    Tobias Spronk
    Oliver Kraff
    Gregor Schaefers
    Harald H. Quick
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2023, 36 : 725 - 735
  • [26] SAFETY OF METALLIC SURGICAL CLIPS IN PATIENTS UNDERGOING HIGH-FIELD-STRENGTH MAGNETIC-RESONANCE IMAGING
    GOLD, JP
    PULSINELLI, W
    WINCHESTER, P
    BRILL, PW
    JACEWICZ, M
    ISOM, OW
    ANNALS OF THORACIC SURGERY, 1989, 48 (05): : 643 - 645
  • [27] Minimizing artifacts caused by metallic implants at MR imaging: Experimental and clinical studies
    Suh, JS
    Jeong, EK
    Shin, KH
    Cho, JH
    Na, JB
    Kim, DH
    Han, CD
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1998, 171 (05) : 1207 - 1213
  • [28] Brain tumor resection: Intraoperative monitoring with high-field-strength MR imaging-initial results
    Martin, AJ
    Hall, WA
    Liu, HY
    Pozza, CH
    Michel, E
    Casey, SO
    Maxwell, RE
    Truwit, CL
    RADIOLOGY, 2000, 215 (01) : 221 - 228
  • [29] Osteochondral Lesions of the Talus: Retrograde Drilling with High-Field-Strength MR Guidance
    Seebauer, Christian J.
    Bail, Hermann J.
    Wichlas, Florian
    Jung, Tobias
    Papanikolaou, Ioannis S.
    van der Voort, Ivo
    Rump, Jens C.
    Schilling, Rene
    Winkelmann, Andreas
    Walther, Thula
    Chopra, Sasha S.
    Teichgraeber, Ulf K. M.
    RADIOLOGY, 2009, 252 (03) : 857 - 864
  • [30] Gradient field switching as a source for artifacts in MR imaging of metallic stents
    Shenhav, A
    Azhari, H
    MAGNETIC RESONANCE IN MEDICINE, 2004, 52 (06) : 1465 - 1468