Weighted singular value decomposition (wSVD) to improve the radiation dose efficiency of grating based x-ray phase contrast imaging with a photon counting detector

被引:0
|
作者
Ji, Xu [1 ]
Ge, Yongshuai [1 ]
Zhang, Ran [1 ]
Li, Ke [1 ,2 ]
Chen, Guang-Hong [1 ,2 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Sch Med & Publ Hlth, 1530 Med Sci Ctr, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Radiol, Sch Med & Publ Hlth, Madison, WI 53706 USA
来源
MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING | 2017年 / 10132卷
关键词
X-ray differential phase contrast imaging; photon counting detector; Talbot interferometer; singular value decomposition; contrast-to-noise ratio; low rank approximation; INTERFEROMETER; NOISE;
D O I
10.1117/12.2255014
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The noise performance of grating-based differential phase contrast (DPC) imaging system is strongly dependent on the fringe visibility of the grating interferometer. Since the grating interferometer system is usually designed to be operated at a specific energy, deviation from that energy may lead to visibility loss and increased noise. By incorporating an energy-discriminating photon counting detector (PCD) into the system, photons with energies close to the operation energy of the interferometer can be selected, which offers the possibility of contrast-to-noise ratio (CNR) improvement. In our previous work, a singular value decomposition (SVD)-based rank one approximation method was developed to improve the CNR of DPC imaging. However, as the noise level and energy sensitivity of the interferometer may vary significantly from one energy bin to another, the signal and noise may not be separated well using the previously proposed method, therefore the full potential of the SVD method may not be achieved. This work presents a weighted SVD-based method, which maintains the noise reduction capability regardless of the similarity in the noise level across energy bins. The optimal weighting scheme was theoretically derived, and experimental phantom studies were performed to validate the theory and demonstrate the improved radiation dose efficiency of the proposed weighted SVD method.
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Development of x-ray scintillator functioning also as an analyser grating used in grating-based x-ray differential phase contrast imaging
    雷耀虎
    刘鑫
    郭金川
    赵志刚
    牛憨笨
    Chinese Physics B, 2011, 20 (04) : 226 - 231
  • [42] Development of x-ray scintillator functioning also as an analyser grating used in grating-based x-ray differential phase contrast imaging
    Lei Yao-Hu
    Liu Xin
    Guo Jin-Chuan
    Zhao Zhi-Gang
    Niu Han-Ben
    CHINESE PHYSICS B, 2011, 20 (04)
  • [43] The Effects of Spectral Distortion on Multi-Energy X-ray Imaging Based on Photon Counting Detector
    Cho, Hyo-Min
    Choi, Yu-Na
    Lee, Seung-Wan
    Ryu, Hyun-Ju
    Lee, Young-Jin
    Kim, Hee-Joung
    2011 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2011, : 3001 - 3003
  • [44] Performance of Amorphous Selenium Based Unipolar Charge Sensing Detector for Photon Counting X-ray Imaging
    Camlica, Ahmet
    Lee, Denny
    Jang, Hyunsuk
    Arnab, Salman M.
    Fang, Yuan
    Kabir, M. Z.
    Karim, S. Karim
    MEDICAL IMAGING 2020: PHYSICS OF MEDICAL IMAGING, 2020, 11312
  • [45] Shifting curves based on the detector integration effect for x-ray phase contrast imaging
    Yang, Jun
    Guo, Jin-Chuan
    Lei, Yao-Hu
    Yi, Ming-Hao
    Chen, Li
    CHINESE PHYSICS B, 2017, 26 (02)
  • [46] Shifting curves based on the detector integration effect for x-ray phase contrast imaging
    杨君
    郭金川
    雷耀虎
    易明皓
    陈力
    Chinese Physics B, 2017, 26 (02) : 516 - 519
  • [47] Reducing radiation dose in grating based x-ray phase contrast CT with twin-peaks in its phase stepping curves
    Xie, Huiqiao
    Cai, Weixing
    Yang, Lily
    Mao, Hui
    Tang, Xiangyang
    MEDICAL PHYSICS, 2016, 43 (11) : 5942 - 5950
  • [48] Hard x-ray phase contrast imaging using single absorption grating and hybrid semiconductor pixel detector
    Krejci, Frantisek
    Jakubek, Jan
    Kroupa, Martin
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2010, 81 (11):
  • [49] High sensitivity phase retrieval method in grating-based x-ray phase contrast imaging
    Wu, Zhao
    Gao, Kun
    Chen, Jian
    Wang, Dajiang
    Wang, Shenghao
    Chen, Heng
    Bao, Yuan
    Shao, Qigang
    Wang, Zhili
    Zhang, Kai
    Zhu, Peiping
    Wu, Ziyu
    MEDICAL PHYSICS, 2015, 42 (02) : 741 - 749
  • [50] Analysis of partial coherence in grating-based phase-contrast X-ray imaging
    Wang, Zhili
    Liu, Xiaosong
    Zhu, Peiping
    Huang, Wanxia
    Yuan, Qingxi
    Li, Enrong
    Liu, Yijin
    Zhang, Kai
    Hong, Youli
    Wu, Ziyu
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2010, 619 (1-3): : 319 - 322