Weighted singular value decomposition (wSVD) to improve the radiation dose efficiency of grating based x-ray phase contrast imaging with a photon counting detector

被引:0
|
作者
Ji, Xu [1 ]
Ge, Yongshuai [1 ]
Zhang, Ran [1 ]
Li, Ke [1 ,2 ]
Chen, Guang-Hong [1 ,2 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Sch Med & Publ Hlth, 1530 Med Sci Ctr, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Radiol, Sch Med & Publ Hlth, Madison, WI 53706 USA
来源
MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING | 2017年 / 10132卷
关键词
X-ray differential phase contrast imaging; photon counting detector; Talbot interferometer; singular value decomposition; contrast-to-noise ratio; low rank approximation; INTERFEROMETER; NOISE;
D O I
10.1117/12.2255014
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The noise performance of grating-based differential phase contrast (DPC) imaging system is strongly dependent on the fringe visibility of the grating interferometer. Since the grating interferometer system is usually designed to be operated at a specific energy, deviation from that energy may lead to visibility loss and increased noise. By incorporating an energy-discriminating photon counting detector (PCD) into the system, photons with energies close to the operation energy of the interferometer can be selected, which offers the possibility of contrast-to-noise ratio (CNR) improvement. In our previous work, a singular value decomposition (SVD)-based rank one approximation method was developed to improve the CNR of DPC imaging. However, as the noise level and energy sensitivity of the interferometer may vary significantly from one energy bin to another, the signal and noise may not be separated well using the previously proposed method, therefore the full potential of the SVD method may not be achieved. This work presents a weighted SVD-based method, which maintains the noise reduction capability regardless of the similarity in the noise level across energy bins. The optimal weighting scheme was theoretically derived, and experimental phantom studies were performed to validate the theory and demonstrate the improved radiation dose efficiency of the proposed weighted SVD method.
引用
收藏
页数:6
相关论文
共 50 条
  • [21] Photon-counting, energy-resolving and super-resolution phase contrast X-ray imaging using an integrating detector
    O'Connell, Dylan W.
    Morgan, Kaye S.
    Ruben, Gary
    Schaff, Florian
    Croton, Linda C. P.
    Buckley, Genevieve A.
    Paganin, David M.
    Uesugi, Kentaro
    Kitchen, Marcus J.
    OPTICS EXPRESS, 2020, 28 (05) : 7080 - 7094
  • [22] Improving radiation dose efficiency of X-ray differential phase contrast imaging using an energy-resolving grating interferometer and a novel rank constraint
    Ge, Yongshuai
    Zhang, Ran
    Li, Ke
    Chen, Guang-Hong
    OPTICS EXPRESS, 2016, 24 (12): : 12955 - 12968
  • [23] Dual phase grating based X-ray differential phase contrast imaging with source grating: theory and validation
    Ge, Yongshuai
    Chen, Jianwei
    Zhu, Peiping
    Yang, Jun
    Deng, Shiwo
    Shi, Wei
    Zhang, Kai
    Guo, Jinchuan
    Zhang, Huitao
    Zheng, Hairong
    Liang, Dong
    OPTICS EXPRESS, 2020, 28 (07) : 9786 - 9801
  • [24] Grating based x-ray differential phase contrast imaging without mechanical phase stepping
    Ge, Yongshuai
    Li, Ke
    Garrett, John
    Chen, Guang-Hong
    OPTICS EXPRESS, 2014, 22 (12): : 14246 - 14252
  • [25] Single absorption grating based X-ray phase contrast CT using Timepix detector
    Zemlicka, J.
    Dudak, J.
    Kubanda, D.
    Krejci, F.
    JOURNAL OF INSTRUMENTATION, 2019, 14
  • [26] Estimation of an Atomic Density with a Singular Value Decomposition Method. Using a Photon-Counting X-ray CT
    Ito, Ryo
    Ogawa, Koichi
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [27] Simulation and measurement of grating-based X-ray phase-contrast imaging
    Bartl, P.
    Bayer, F.
    Durst, J.
    Haas, W.
    Michel, T.
    Pelzer, G.
    Ritter, A.
    Weber, T.
    Anton, G.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2011, 648 : S269 - S272
  • [28] Grating-based X-ray phase-contrast imaging at PETRA III
    Hipp, A.
    Beckmann, F.
    Lytaev, P.
    Greving, I.
    Lottermoser, L.
    Dose, T.
    Kirchhof, R.
    Burmester, H.
    Schreyer, A.
    Herzen, J.
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IX, 2014, 9212
  • [29] Energy weighting in grating-based x-ray phase-contrast imaging
    Pelzer, Georg
    Weber, Thomas
    Anton, Gisela
    Sune, Rafael Ballabriga
    Bayer, Florian
    Campbell, Michael
    Haas, Wilhelm
    Horn, Florian
    Cudie, Xavi Llopart
    Michel, Norbert
    Mollenbauer, Uwe
    Rieger, Jens
    Ritter, Andre
    Ritter, Ina
    Woelfel, Stefan
    Wong, Winnie S.
    Zang, Andrea
    Michel, Thilo
    MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING, 2014, 9033
  • [30] Correcting Intensity Drift in X-ray Grating-based Phase Contrast Imaging
    Zhang, P.
    Shao, Q.
    Hu, R.
    Wang, S.
    Zan, G.
    Wang, S.
    Bao, Y.
    Wali, F.
    Tian, Y.
    Liu, G.
    Wang, Z.
    Gao, K.
    JOURNAL OF INSTRUMENTATION, 2016, 11