Weighted singular value decomposition (wSVD) to improve the radiation dose efficiency of grating based x-ray phase contrast imaging with a photon counting detector

被引:0
|
作者
Ji, Xu [1 ]
Ge, Yongshuai [1 ]
Zhang, Ran [1 ]
Li, Ke [1 ,2 ]
Chen, Guang-Hong [1 ,2 ]
机构
[1] Univ Wisconsin, Dept Med Phys, Sch Med & Publ Hlth, 1530 Med Sci Ctr, Madison, WI 53706 USA
[2] Univ Wisconsin, Dept Radiol, Sch Med & Publ Hlth, Madison, WI 53706 USA
关键词
X-ray differential phase contrast imaging; photon counting detector; Talbot interferometer; singular value decomposition; contrast-to-noise ratio; low rank approximation; INTERFEROMETER; NOISE;
D O I
10.1117/12.2255014
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
The noise performance of grating-based differential phase contrast (DPC) imaging system is strongly dependent on the fringe visibility of the grating interferometer. Since the grating interferometer system is usually designed to be operated at a specific energy, deviation from that energy may lead to visibility loss and increased noise. By incorporating an energy-discriminating photon counting detector (PCD) into the system, photons with energies close to the operation energy of the interferometer can be selected, which offers the possibility of contrast-to-noise ratio (CNR) improvement. In our previous work, a singular value decomposition (SVD)-based rank one approximation method was developed to improve the CNR of DPC imaging. However, as the noise level and energy sensitivity of the interferometer may vary significantly from one energy bin to another, the signal and noise may not be separated well using the previously proposed method, therefore the full potential of the SVD method may not be achieved. This work presents a weighted SVD-based method, which maintains the noise reduction capability regardless of the similarity in the noise level across energy bins. The optimal weighting scheme was theoretically derived, and experimental phantom studies were performed to validate the theory and demonstrate the improved radiation dose efficiency of the proposed weighted SVD method.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] X-ray differential phase contrast imaging using a grating interferometer and a single photon counting detector
    Ge, Yongshuai
    Zhang, Ran
    Li, Ke
    Chen, Guang-Hong
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [2] Improvement of the visibility for X-ray Phase Contrast Imaging using Photon Counting Detector
    Sano, S.
    Tanabe, K.
    Yoshimuta, T.
    Kimura, K.
    Shirai, T.
    Doki, T.
    Horiba, A.
    Sato, T.
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [3] Spectral X-ray phase contrast imaging with a CdTe photon-counting detector
    Navarrete, Carlos
    Procz, Simon
    Schuetz, Michael Kilian
    Roque, Gerardo
    Fey, Julian
    Avila, Carlos
    Olivo, Alessandro
    Fiederle, Michael
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2020, 971 (971):
  • [4] Grating-based x-ray phase-contrast imaging with a multi energy-channel photon-counting pixel detector
    Pelzer, Georg
    Weber, Thomas
    Anton, Gisela
    Ballabriga, Rafael
    Bayer, Florian
    Campbell, Michael
    Gabor, Thomas
    Haas, Wilhelm
    Horn, Florian
    Llopart, Xavi
    Michel, Norbert
    Mollenbauer, Uwe
    Rieger, Jens
    Ritter, Andre
    Ritter, Ina
    Sievers, Peter
    Woelfel, Stefan
    Wong, Winnie S.
    Zang, Andrea
    Michel, Thilo
    OPTICS EXPRESS, 2013, 21 (22): : 25677 - 25684
  • [5] The Effect of Photon Energy Weighting on X-ray Imaging Based on a Photon Counting Detector
    Choi, Yu-Na
    Lee, Seung-Wan
    Cho, Hyo-Min
    Ryu, Hyun-Ju
    Lee, Young-Jin
    Kim, Hee-Joung
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2011, 59 (05) : 3114 - 3119
  • [6] Low-dose and fast grating-based x-ray phase-contrast imaging
    Wali, Faiz
    Wang, Shenghao
    Han, Huajie
    Gao, Kun
    Wu, Zhao
    Zhu, Peiping
    Tian, Yangchao
    OPTICAL ENGINEERING, 2017, 56 (09)
  • [7] Uniformity Correction in Photon-counting X-ray Detector Based on Basis Material Decomposition
    Wang, Xiaolan
    He, Xin
    Taguchi, Katsuyuki
    Patt, Bradley E.
    Wagenaar, Douglas J.
    Frey, Eric C.
    2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9, 2009, : 4168 - +
  • [8] Single-step phase contrast x-ray imaging using photon counting detectors
    Guersoy, Doga
    Das, Mini
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [9] Experimental Study of X-ray Phase Contrast Imaging Based on Cascaded Grating
    Li Ji
    Huang Jian-heng
    Lei Yao-hu
    Liu Xin
    Zhao Zhi-gang
    ACTA PHOTONICA SINICA, 2019, 48 (01)
  • [10] Grating-based X-ray phase contrast for biomedical imaging applications
    Pfeiffer, Franz
    Herzen, Julia
    Wiliner, Marian
    Chabior, Michael
    Auweter, Sigrid
    Reiser, Maximilian
    Bamberg, Fabian
    ZEITSCHRIFT FUR MEDIZINISCHE PHYSIK, 2013, 23 (03): : 176 - 185