Accuracy and reproducibility of fast fractional flow reserve computation from invasive coronary angiography

被引:31
|
作者
van Rosendael, A. R. [1 ]
Koning, G. [2 ]
Dimitriu-Leen, A. C. [1 ]
Smit, J. M. [1 ]
Montero-Cabezas, J. M. [1 ]
van der Kley, F. [1 ]
Jukema, J. W. [1 ]
Reiber, J. H. C. [2 ,3 ]
Bax, J. J. [1 ]
Scholte, A. J. H. A. [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Cardiol, Albinusdreef 2,Postal Zone 2300 RC, NL-2333 ZA Leiden, Netherlands
[2] Medis Med Imaging Syst BV, Leiden, Netherlands
[3] Leiden Univ, Med Ctr, Dept Radiol, Leiden, Netherlands
来源
关键词
Fractional flow reserve; Computational fluid dynamics; Quantitative coronary angiography;
D O I
10.1007/s10554-017-1190-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Fractional flow reserve (FFR) guided percutaneous coronary intervention (PCI) is associated with favourable outcome compared with revascularization based on angiographic stenosis severity alone. The feasibility of the new image-based quantitative flow ratio (QFR) assessed from 3D quantitative coronary angiography (QCA) and thrombolysis in myocardial infarction (TIMI) frame count using three different flow models has been reported recently. The aim of the current study was to assess the accuracy, and in particular, the reproducibility of these three QFR techniques when compared with invasive FFR. QFR was derived (1) from adenosine induced hyperaemic coronary angiography images (adenosine-flow QFR [aQFR]), (2) from non-hyperemic images (contrast-flow QFR [cQFR]) and (3) using a fixed empiric hyperaemic flow [fixed-flow QFR (fQFR)]. The three QFR values were calculated in 17 patients who prospectively underwent invasive FFR measurement in 20 vessels. Two independent observers performed the QFR analyses. Mean difference, standard deviation and 95% limits of agreement (LOA) between invasive FFR and aQFR, cQFR and fQFR for observer 1 were: 0.01 +/- 0.04 (95% LOA: -0.07; 0.10), 0.01 +/- 0.05 (95% LOA: -0.08; 0.10), 0.01 +/- 0.04 (95% LOA: -0.06; 0.08) and for observer 2: 0.00 +/- 0.03 (95% LOA: -0.06; 0.07), -0.01 +/- 0.03 (95% LOA: -0.07; 0.05), 0.00 +/- 0.03 (95% LOA: -0.06; 0.05). Values between the 2 observers were (to assess reproducibility) for aQFR: 0.01 +/- 0.04 (95% LOA: -0.07; 0.09), for cQFR: 0.02 +/- 0.04 (95% LOA: -0.06; 0.09) and for fQFR: 0.01 +/- 0.05 (95% LOA: -0.07; 0.10). In a small number of patients we showed good accuracy of three QFR techniques (aQFR, cQFR and fQFR) to predict invasive FFR. Furthermore, good inter-observer agreement of the QFR values was observed between two independent observers.
引用
收藏
页码:1305 / 1312
页数:8
相关论文
共 50 条
  • [1] Accuracy and reproducibility of fast fractional flow reserve computation from invasive coronary angiography
    A. R. van Rosendael
    G. Koning
    A. C. Dimitriu-Leen
    J. M. Smit
    J. M. Montero-Cabezas
    F. van der Kley
    J. W. Jukema
    J. H. C. Reiber
    J. J. Bax
    A. J. H. A. Scholte
    The International Journal of Cardiovascular Imaging, 2017, 33 : 1305 - 1312
  • [2] ACCURACY OF VIRTUAL FRACTIONAL FLOW RESERVE COMPUTATION FROM INVASIVE CORONARY ANGIOGRAPHY IN DAILY PRACTICE
    El Kasty, Mohamad
    Rezine, Zhor
    Hakim, Maher
    Viana, Vincent
    Elhadad, Simon
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2021, 77 (18) : 937 - 937
  • [3] Accuracy of Fractional Flow Reserve Derived From Coronary Angiography
    Fearon, William F.
    Achenbach, Stephan
    Engstrom, Thomas
    Assali, Abid
    Shlofmitz, Richard
    Jeremias, Allen
    Fournier, Stephane
    Kirtane, Ajay J.
    Kornowski, Ran
    Greenberg, Gabriel
    Jubeh, Rami
    Kolansky, Daniel M.
    McAndrew, Thomas
    Dressler, Ovidiu
    Maehara, Akiko
    Matsumura, Mitsuaki
    Leon, Martin B.
    De Bruyne, Bernard
    CIRCULATION, 2019, 139 (04) : 477 - 484
  • [4] Accuracy and Reproducibility of Coronary Angiography-Derived Fractional Flow Reserve in the Assessment of Coronary Lesion Severity
    Yang, Guojian
    Li, Le
    Peng, Xi
    Tang, Guodong
    Zheng, Naixin
    Zhao, Ying
    Li, Hui
    Zhang, Huiping
    Sun, Fucheng
    Ai, Hu
    INTERNATIONAL JOURNAL OF GENERAL MEDICINE, 2023, 16 : 3805 - 3814
  • [5] Virtual Fractional Flow Reserve Derived From Invasive Coronary Angiography
    Fan, Guoxin
    Qi, Xiaolong
    Yang, Changqing
    Fu, Qingsong
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2014, 84 (02) : E16 - E17
  • [6] Accuracy and usefulness of noninvasive fractional flow reserve from computed tomographic coronary angiography: comparison with myocardial perfusion imaging, echocardiographic coronary flow reserve, and invasive fractional flow reserve
    Taguchi E.
    Nakao K.
    Hirakawa K.
    Fukunaga T.
    Miyamoto S.
    Sakamoto T.
    Cardiovascular Intervention and Therapeutics, 2017, 32 (1) : 66 - 71
  • [7] Diagnostic Accuracy of a Fast Computational Approach to Derive Fractional Flow Reserve From Coronary CT Angiography
    Li, Zehang
    Zhang, Jiayin
    Xu, Lei
    Yang, Wenjie
    Li, Guanyu
    Ding, Daixin
    Chang, Yunxiao
    Yu, Mengmeng
    Kitslaar, Pieter
    Zhang, Su
    Reiber, Johan H. C.
    Arbab-Zadeh, Armin
    Yan, Fuhua
    Tu, Shengxian
    JACC-CARDIOVASCULAR IMAGING, 2020, 13 (01) : 172 - 175
  • [8] Computing Fractional Flow Reserve From Invasive Coronary Angiography Getting Closer
    Morris, Paul D.
    Gunn, Julian P.
    CIRCULATION-CARDIOVASCULAR INTERVENTIONS, 2017, 10 (09)
  • [9] Accuracy of analytically determined fractional flow reserve derived from coronary angiography for non-invasive assessment of coronary artery stenosis
    Milovanovic, Aleksandar
    Isailovic, Velibor
    Saveljic, Igor
    Filipovic, Nenad
    TECHNOLOGY AND HEALTH CARE, 2024, 32 (06) : 4613 - 4626
  • [10] Fractional flow reserve and fractional flow reserve gradient from coronary CT angiography for future coronary events
    Hong, D.
    Dai, N.
    Lee, S. H.
    Shin, D.
    Choi, K. H.
    Kim, S. M.
    Park, T. K.
    Yang, J. H.
    Song, Y. B.
    Hahn, J. Y.
    Choi, S. H.
    Choe, Y. H.
    Gwon, H. C.
    Ge, J.
    Lee, J. M.
    EUROPEAN HEART JOURNAL, 2023, 44