Accuracy and Reproducibility of Coronary Angiography-Derived Fractional Flow Reserve in the Assessment of Coronary Lesion Severity

被引:2
|
作者
Yang, Guojian [1 ]
Li, Le [1 ]
Peng, Xi [1 ]
Tang, Guodong [1 ]
Zheng, Naixin [1 ]
Zhao, Ying [1 ]
Li, Hui [1 ]
Zhang, Huiping [1 ]
Sun, Fucheng [1 ]
Ai, Hu [1 ,2 ]
机构
[1] Chinese Acad Med Sci, Beijing Hosp, Inst Geriatr Med, Natl Ctr Gerontol,Dept Cardiol, Beijing 100730, Peoples R China
[2] Chinese Acad Med Sci, Beijing Hosp, Inst Geriatr Med, Natl Ctr Gerontol,Dept Cardiol, 1 DaHua Rd, Beijing 100730, Peoples R China
关键词
fractional flow reserve; computational flow dynamics; grey zone; diagnose; myocardial ischemia; DIAGNOSTIC-ACCURACY; MEDICAL THERAPY; STENOSIS; INTERVENTION; PERFORMANCE; INDEX; RATIO;
D O I
10.2147/IJGM.S413991
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: Coronary angiography-derived fractional flow reserve (caFFR) is a novel computational flow dynamics (CFD)-derived assessment of coronary vessel flow with good diagnostic performance. Herein, we performed a retrospective study to evaluate the reproducibility of caFFR findings between observers and investigate the diagnostic performance of caFFR for coronary stenosis defined as FFR & LE;0.80, especially in the grey zone (0.75 & LE;caFFR & LE;0.80).Patients and Methods: A total of 150 patients (167 coronary vessels) underwent caFFR (with FlashAngio used for calculation of flow variables) and subsequent invasive fractional flow reserve (FFR) measurements. Outcomes, including reproducibility, were compared for vessels in and outside the grey zone.Results: The correlation of caFFR findings was good between the two laboratories (r = 0.723, p<0.001). The AUC of ROC were both high for caFFR-CoreLab1 and caFFR-CoreLab2 (0.975 and 0.883). The diagnostic accuracy, sensitivity, specificity, and negative and positive predictive values were not significantly different between the two laboratories (p>0.05). caFFR had a strong correlation with measures to FFR (r=0.911, p<0.001). There was no systematic difference between caFFR and FFR on Bland-Altman analysis in and outside the grey zone. There was no difference in diagnostic accuracy between the grey and non-grey zones in the prediction of FFR & LE;0.80 (p=0.09).Conclusion: The inter-observer reproducibility for caFFR was high, and the diagnostic accuracy of caFFR was good compared to that of FFR.
引用
收藏
页码:3805 / 3814
页数:10
相关论文
共 50 条
  • [1] Coronary angiography-derived contrast fractional flow reserve
    Gong, Yanjun
    Zheng, Bo
    Yi, Tieci
    Yang, Fan
    Hong, Tao
    Liu, Zhaoping
    Huo, Yunlong
    Li, Jianping
    Huo, Yong
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2022, 99 (03) : 763 - 771
  • [2] Coronary CT Angiography-Derived Fractional Flow Reserve
    Sulaiman N.
    Soon J.
    Leipsic J.
    Current Radiology Reports, 4 (8)
  • [3] Coronary CT Angiography-derived Fractional Flow Reserve
    Tesche, Christian
    De Cecco, Carlo N.
    Albrecht, Moritz H.
    Duguay, Taylor M.
    Bayer, Richard R., II
    Litwin, Sheldon E.
    Steinberg, Daniel H.
    Schoepf, U. Joseph
    RADIOLOGY, 2017, 285 (01) : 17 - 33
  • [4] Diagnostic accuracy of coronary computed tomography angiography-derived fractional flow reserve
    Wenbing Jiang
    Yibin Pan
    Yumeng Hu
    Xiaochang Leng
    Jun Jiang
    Li Feng
    Yongqing Xia
    Yong Sun
    Jian’an Wang
    Jianping Xiang
    Changling Li
    BioMedical Engineering OnLine, 20
  • [5] Diagnostic accuracy of coronary computed tomography angiography-derived fractional flow reserve
    Jiang, Wenbing
    Pan, Yibin
    Hu, Yumeng
    Leng, Xiaochang
    Jiang, Jun
    Li Feng
    Xia, Yongqing
    Sun, Yong
    Wang, Jian'an
    Xiang, Jianping
    Li, Changling
    BIOMEDICAL ENGINEERING ONLINE, 2021, 20 (01)
  • [6] Angiography-Derived Fractional Flow Reserve in Coronary Assessment: Current Developments and Future Perspectives
    Chow, Han Bing
    Tan, Shirley Siang Ning
    Lai, Wei Hong
    Fong, Alan Yean Yip
    CARDIOVASCULAR INNOVATIONS AND APPLICATIONS, 2023, 8 (01)
  • [7] Advancements and future perspectives in coronary angiography-derived fractional flow reserve
    Collet, Carlos
    Amponsah, Daniel K.
    Mahendiran, Thabo
    Mizukami, Takuya
    Wilgenhof, Adriaan
    Fearon, William F.
    PROGRESS IN CARDIOVASCULAR DISEASES, 2025, 88 : 94 - 104
  • [8] Accuracy of Fractional Flow Reserve Derived From Coronary Angiography
    Fearon, William F.
    Achenbach, Stephan
    Engstrom, Thomas
    Assali, Abid
    Shlofmitz, Richard
    Jeremias, Allen
    Fournier, Stephane
    Kirtane, Ajay J.
    Kornowski, Ran
    Greenberg, Gabriel
    Jubeh, Rami
    Kolansky, Daniel M.
    McAndrew, Thomas
    Dressler, Ovidiu
    Maehara, Akiko
    Matsumura, Mitsuaki
    Leon, Martin B.
    De Bruyne, Bernard
    CIRCULATION, 2019, 139 (04) : 477 - 484
  • [9] Sex Differences in Coronary Computed Tomography Angiography-Derived Fractional Flow Reserve
    Fairbairn, Timothy A.
    Dobson, Rebecca
    Hurwitz-Koweek, Lyne
    Matsuo, Hitoshi
    Norgaard, Bjarne L.
    Sand, Niels Peter Ronnow
    Nieman, Koen
    Bax, Jeroen J.
    Pontone, Gianluca
    Raff, Gilbert
    Chinnaiyan, Kavitha M.
    Rabbat, Mark
    Amano, Tetsuya
    Kawasaki, Tomohiro
    Akasaka, Takashi
    Kitabata, Hironori
    Binukrishnan, Sukumaran
    Rogers, Campbell
    Berman, Daniel
    Patel, Manesh R.
    Douglas, Pamela S.
    Leipsic, Jonathon
    JACC-CARDIOVASCULAR IMAGING, 2020, 13 (12) : 2576 - 2587
  • [10] Different Approaches for Coronary Computed Tomography Angiography-Derived Versus Invasive Fractional Flow Reserve Assessment
    Baumann, Stefan
    Akin, Ibrahim
    Borggrefe, Martin
    Ball, B. Devon, Jr.
    Schoepf, U. Joseph
    AMERICAN JOURNAL OF CARDIOLOGY, 2016, 117 (03): : 486 - 486