Accuracy and Reproducibility of Coronary Angiography-Derived Fractional Flow Reserve in the Assessment of Coronary Lesion Severity

被引:2
|
作者
Yang, Guojian [1 ]
Li, Le [1 ]
Peng, Xi [1 ]
Tang, Guodong [1 ]
Zheng, Naixin [1 ]
Zhao, Ying [1 ]
Li, Hui [1 ]
Zhang, Huiping [1 ]
Sun, Fucheng [1 ]
Ai, Hu [1 ,2 ]
机构
[1] Chinese Acad Med Sci, Beijing Hosp, Inst Geriatr Med, Natl Ctr Gerontol,Dept Cardiol, Beijing 100730, Peoples R China
[2] Chinese Acad Med Sci, Beijing Hosp, Inst Geriatr Med, Natl Ctr Gerontol,Dept Cardiol, 1 DaHua Rd, Beijing 100730, Peoples R China
关键词
fractional flow reserve; computational flow dynamics; grey zone; diagnose; myocardial ischemia; DIAGNOSTIC-ACCURACY; MEDICAL THERAPY; STENOSIS; INTERVENTION; PERFORMANCE; INDEX; RATIO;
D O I
10.2147/IJGM.S413991
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: Coronary angiography-derived fractional flow reserve (caFFR) is a novel computational flow dynamics (CFD)-derived assessment of coronary vessel flow with good diagnostic performance. Herein, we performed a retrospective study to evaluate the reproducibility of caFFR findings between observers and investigate the diagnostic performance of caFFR for coronary stenosis defined as FFR & LE;0.80, especially in the grey zone (0.75 & LE;caFFR & LE;0.80).Patients and Methods: A total of 150 patients (167 coronary vessels) underwent caFFR (with FlashAngio used for calculation of flow variables) and subsequent invasive fractional flow reserve (FFR) measurements. Outcomes, including reproducibility, were compared for vessels in and outside the grey zone.Results: The correlation of caFFR findings was good between the two laboratories (r = 0.723, p<0.001). The AUC of ROC were both high for caFFR-CoreLab1 and caFFR-CoreLab2 (0.975 and 0.883). The diagnostic accuracy, sensitivity, specificity, and negative and positive predictive values were not significantly different between the two laboratories (p>0.05). caFFR had a strong correlation with measures to FFR (r=0.911, p<0.001). There was no systematic difference between caFFR and FFR on Bland-Altman analysis in and outside the grey zone. There was no difference in diagnostic accuracy between the grey and non-grey zones in the prediction of FFR & LE;0.80 (p=0.09).Conclusion: The inter-observer reproducibility for caFFR was high, and the diagnostic accuracy of caFFR was good compared to that of FFR.
引用
收藏
页码:3805 / 3814
页数:10
相关论文
共 50 条
  • [41] Clinical Impact of Coronary Computed Tomography Angiography-Derived Fractional Flow Reserve on Japanese Population in the ADVANCE Registry
    Shiono, Yasutsugu
    Matsuo, Hitoshi
    Kawasaki, Tomohiro
    Amano, Tetsuya
    Kitabata, Hironori
    Kubo, Takashi
    Morino, Yoshihiro
    Yoda, Shunichi
    Sakamoto, Tomohiro
    Ito, Hiroshi
    Shite, Junya
    Otake, Hiromasa
    Tanaka, Nobuhiro
    Terashima, Mitsuyasu
    Kadota, Kazushige
    Patel, Manesh R.
    Nieman, Koen
    Rogers, Campbell
    Norgaard, Bjarne L.
    Bax, Jeroen J.
    Raff, Gilbert L.
    Chinnaiyan, Kavitha M.
    Berman, Daniel S.
    Fairbairn, Timothy A.
    Koweek, Lynne M. Hurwitz
    Leipsic, Jonathon
    Akasaka, Takashi
    CIRCULATION JOURNAL, 2019, 83 (06) : 1293 - 1301
  • [42] The impact of deep learning reconstruction on image quality and coronary CT angiography-derived fractional flow reserve values
    Cheng Xu
    Min Xu
    Jing Yan
    Yan-Yu Li
    Yan Yi
    Yu-Bo Guo
    Ming Wang
    Yu-Mei Li
    Zheng-Yu Jin
    Yi-Ning Wang
    European Radiology, 2022, 32 : 7918 - 7926
  • [43] Coronary Computed Tomography Angiography-derived Fractional Flow Reserve An Expert Consensus Document of Chinese Society of Radiology
    Zhang, Long Jiang
    Tang, Chunxiang
    Xu, Pengpeng
    Guo, Bangjun
    Zhou, Fan
    Xue, Yi
    Zhang, Jiayin
    Zheng, Minwen
    Xu, Lei
    Hou, Yang
    Lu, Bin
    Guo, Youmin
    Cheng, Jingliang
    Liang, Changhong
    Song, Bin
    Zhang, Huimao
    Hong, Nan
    Wang, Peijun
    Chen, Min
    Xu, Ke
    Liu, Shiyuan
    Jin, Zhengyu
    Lu, Guangming
    JOURNAL OF THORACIC IMAGING, 2022, 37 (06) : 385 - 400
  • [44] Graft patency and progression of coronary artery disease after CABG assessed by angiography-derived fractional flow reserve
    Gigante, Carlo
    Mizukami, Takuya
    Sonck, Jeroen
    Tanzilli, Alessandra
    Bartunek, Jozef
    Barbato, Emanuele
    Pompilio, Giulio
    Mushtaq, Saima
    Bartorelli, Antonio
    De Bruyne, Bernard
    Andreini, Daniele
    Collet, Carlos
    EUROPEAN HEART JOURNAL SUPPLEMENTS, 2019, 21 (0J) : J157 - J157
  • [45] Graft Patency and Progression of Coronary Artery Disease after CABG Assessed by Angiography-Derived Fractional Flow Reserve
    Sonck, Jeroen
    Andreini, Daniele
    Collet, Carlos
    De Bruyne, Bernard
    Gigante, Carlo
    Mizukami, Takuya
    Nagumo, Sakura
    ACTA CARDIOLOGICA, 2020, 75 : 40 - 41
  • [46] Is it the Time to Move Towards Coronary Computed Tomography Angiography-Derived Fractional Flow Reserve Guided Percutaneous Coronary Intervention? The Pros and Cons
    Sharifkazemi, Mohammadbagher
    Hooshanginezhad, Zahra
    Zoroufian, Arezou
    Shamsa, Kamran
    CURRENT CARDIOLOGY REVIEWS, 2023, 19 (04) : 14 - 23
  • [47] Coronary CT angiography-derived fractional flow reserve in-stable angina: association with recurrent chest pain
    Madsen, Kristian Taekker
    Veien, Karsten Tange
    Larsen, Pia
    Husain, Majed
    Deibjerg, Lone
    Junker, Anders
    Kusk, Martin Weber
    Thomsen, Kristian Korsgaard
    Rohold, Allan
    Jensen, Lisette Okkels
    Sand, Niels Peter Ronnow
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2022, 23 (11) : 1511 - 1519
  • [48] The impact of deep learning reconstruction on image quality and coronary CT angiography-derived fractional flow reserve values
    Xu, Cheng
    Xu, Min
    Yan, Jing
    Li, Yan-Yu
    Yi, Yan
    Guo, Yu-Bo
    Wang, Ming
    Li, Yu-Mei
    Jin, Zheng-Yu
    Wang, Yi-Ning
    EUROPEAN RADIOLOGY, 2022, 32 (11) : 7918 - 7926
  • [49] Combining anatomy and physiology: New angiography-based and computed tomography coronary angiography-derived fractional flow reserve indices
    Tomaniak, Mariusz
    Serruys, Patrick W.
    CARDIOLOGY JOURNAL, 2020, 27 (03) : 225 - 229
  • [50] Sex differences in computed tomography angiography-derived coronary plaque burden in relation to invasive fractional flow reserve
    Han, Donghee
    van Diemen, Pepijn
    Kuronuma, Keiichiro
    Lin, Andrew
    Motwani, Manish
    McElhinney, Priscilla
    Tomasino, Guadalupe Flores
    Park, Caroline
    Kwan, Alan
    Tzolos, Evangelos
    Klein, Eyal
    Grodecki, Kajetan
    Shou, Benjamin
    Tamarappoo, Balaji
    Cadet, Sebastien
    Danad, Ibrahim
    Driessen, Roel S.
    Berman, Daniel S.
    Slomka, Piotr J.
    Dey, Damini
    Knaapen, Paul
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2023, 17 (02) : 112 - 119