Accuracy and reproducibility of fast fractional flow reserve computation from invasive coronary angiography

被引:31
|
作者
van Rosendael, A. R. [1 ]
Koning, G. [2 ]
Dimitriu-Leen, A. C. [1 ]
Smit, J. M. [1 ]
Montero-Cabezas, J. M. [1 ]
van der Kley, F. [1 ]
Jukema, J. W. [1 ]
Reiber, J. H. C. [2 ,3 ]
Bax, J. J. [1 ]
Scholte, A. J. H. A. [1 ]
机构
[1] Leiden Univ, Med Ctr, Dept Cardiol, Albinusdreef 2,Postal Zone 2300 RC, NL-2333 ZA Leiden, Netherlands
[2] Medis Med Imaging Syst BV, Leiden, Netherlands
[3] Leiden Univ, Med Ctr, Dept Radiol, Leiden, Netherlands
来源
关键词
Fractional flow reserve; Computational fluid dynamics; Quantitative coronary angiography;
D O I
10.1007/s10554-017-1190-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Fractional flow reserve (FFR) guided percutaneous coronary intervention (PCI) is associated with favourable outcome compared with revascularization based on angiographic stenosis severity alone. The feasibility of the new image-based quantitative flow ratio (QFR) assessed from 3D quantitative coronary angiography (QCA) and thrombolysis in myocardial infarction (TIMI) frame count using three different flow models has been reported recently. The aim of the current study was to assess the accuracy, and in particular, the reproducibility of these three QFR techniques when compared with invasive FFR. QFR was derived (1) from adenosine induced hyperaemic coronary angiography images (adenosine-flow QFR [aQFR]), (2) from non-hyperemic images (contrast-flow QFR [cQFR]) and (3) using a fixed empiric hyperaemic flow [fixed-flow QFR (fQFR)]. The three QFR values were calculated in 17 patients who prospectively underwent invasive FFR measurement in 20 vessels. Two independent observers performed the QFR analyses. Mean difference, standard deviation and 95% limits of agreement (LOA) between invasive FFR and aQFR, cQFR and fQFR for observer 1 were: 0.01 +/- 0.04 (95% LOA: -0.07; 0.10), 0.01 +/- 0.05 (95% LOA: -0.08; 0.10), 0.01 +/- 0.04 (95% LOA: -0.06; 0.08) and for observer 2: 0.00 +/- 0.03 (95% LOA: -0.06; 0.07), -0.01 +/- 0.03 (95% LOA: -0.07; 0.05), 0.00 +/- 0.03 (95% LOA: -0.06; 0.05). Values between the 2 observers were (to assess reproducibility) for aQFR: 0.01 +/- 0.04 (95% LOA: -0.07; 0.09), for cQFR: 0.02 +/- 0.04 (95% LOA: -0.06; 0.09) and for fQFR: 0.01 +/- 0.05 (95% LOA: -0.07; 0.10). In a small number of patients we showed good accuracy of three QFR techniques (aQFR, cQFR and fQFR) to predict invasive FFR. Furthermore, good inter-observer agreement of the QFR values was observed between two independent observers.
引用
收藏
页码:1305 / 1312
页数:8
相关论文
共 50 条
  • [41] Modeling of Fractional Flow Reserve Based on Coronary CT Angiography
    Grunau, Gilat L.
    Min, James K.
    Leipsic, Jonathon
    CURRENT CARDIOLOGY REPORTS, 2013, 15 (01)
  • [42] Coronary CT Angiography-Derived Fractional Flow Reserve
    Sulaiman N.
    Soon J.
    Leipsic J.
    Current Radiology Reports, 4 (8)
  • [43] Modeling of Fractional Flow Reserve Based on Coronary CT Angiography
    Gilat L. Grunau
    James K. Min
    Jonathon Leipsic
    Current Cardiology Reports, 2013, 15
  • [44] Fractional Flow Reserve Estimation by Coronary Computed Tomography Angiography
    Martus, Peter
    Schueler, Sabine
    Dewey, Marc
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (15) : 1410 - 1411
  • [45] The effect of blood pressure on non-invasive fractional flow reserve derived from coronary computed tomography angiography
    Akira Kurata
    Adriaan Coenen
    Marisa M. Lubbers
    Koen Nieman
    Teruhito Kido
    Tomoyuki Kido
    Natsumi Yamashita
    Kouki Watanabe
    Gabriel P. Krestin
    Teruhito Mochizuki
    European Radiology, 2017, 27 : 1416 - 1423
  • [46] Validation of a Prediction Model From Quantitative Coronary Angiography to Detect Ischaemic Lesions as Evaluated by Invasive Fractional Flow Reserve
    Yang, Shuai
    Leng, Shuang
    Fam, Jiang Ming
    Low, Adrian Fatt Hoe
    Tan, Ru-San
    Chai, Ping
    Teo, Lynette
    Chin, Chee Yang
    Allen, John C.
    Chan, Mark Yan-Yee
    Yeo, Khung Keong
    Wong, Aaron Sung Lung
    Wu, Qinghua
    Lim, Soo Teik
    Zhong, Liang
    HEART LUNG AND CIRCULATION, 2025, 34 (02): : 125 - 134
  • [47] Cost analysis of non-invasive fractional flow reserve derived from coronary computed tomographic angiography in Japan
    Kimura T.
    Shiomi H.
    Kuribayashi S.
    Isshiki T.
    Kanazawa S.
    Ito H.
    Ikeda S.
    Forrest B.
    Zarins C.K.
    Hlatky M.A.
    Norgaard B.L.
    Cardiovascular Intervention and Therapeutics, 2015, 30 (1) : 38 - 44
  • [48] The effect of blood pressure on non-invasive fractional flow reserve derived from coronary computed tomography angiography
    Kurata, Akira
    Coenen, Adriaan
    Lubbers, Marisa M.
    Nieman, Koen
    Kido, Teruhito
    Kido, Tomoyuki
    Yamashita, Natsumi
    Watanabe, Kouki
    Krestin, Gabriel P.
    Mochizuki, Teruhito
    EUROPEAN RADIOLOGY, 2017, 27 (04) : 1416 - 1423
  • [49] Fractional flow reserve derived from coronary CT angiography in stable coronary disease: a new standard in non-invasive testing?
    Norgaard, B. L.
    Jensen, J. M.
    Leipsic, J.
    EUROPEAN RADIOLOGY, 2015, 25 (08) : 2282 - 2290
  • [50] Fractional flow reserve derived from coronary CT angiography in stable coronary disease: a new standard in non-invasive testing?
    B. L. Nørgaard
    J. M. Jensen
    J. Leipsic
    European Radiology, 2015, 25 : 2282 - 2290