A 3D two-point method for whole-brain water content and relaxation time mapping: Comparison with gold standard methods

被引:9
|
作者
Schall, Melissa [1 ]
Zimmermann, Markus [1 ]
Iordanishvili, Elene [1 ]
Gu, Yun [1 ]
Shah, N. Jon [1 ,2 ,3 ,4 ]
Oros-Peusquens, Ana-Maria [1 ]
机构
[1] Res Ctr Julich, INM 4, Julich, Germany
[2] Res Ctr Julich, INM 11, Julich, Germany
[3] Julich Aachen Res Alliance JARA BRAIN Translat Me, Aachen, Germany
[4] Rhein Westfal TH Aachen, Dept Neurol, Aachen, Germany
来源
PLOS ONE | 2018年 / 13卷 / 08期
基金
美国国家科学基金会;
关键词
HIGH-RESOLUTION T-1; MAGNETIC-FIELD; QUANTITATIVE T-1; SPOILED FLASH; TISSUE; ACCURACY; BIAS;
D O I
10.1371/journal.pone.0201013
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Quantitative imaging of the human brain is of great interest in clinical research as it enables the identification of a range of MR biomarkers useful in diagnosis, treatment and prognosis of a wide spectrum of diseases. Here, a 3D two-point method for water content and relaxation time mapping is presented and compared to established gold standard methods. The method determines free water content, H2O, and the longitudinal relaxation time, T-1, quantitatively from a two-point fit to the signal equation including corrections of the transmit and receive fields. In addition, the effective transverse relaxation time, T-2*, is obtained from an exponential fit to the multi-echo signal train and its influence on H2O values is corrected. The phantom results obtained with the proposed method show good agreement for H2O and T-1 values with known and spectroscopically measured values, respectively. The method is compared in vivo to already established gold standard quantitative methods. For H2O and T-2* mapping, the 3D two-point results were compared to a measurement conducted with a multiple-echo GRE with long TR and T-1 is compared to results from a Look-Locker method, TAPIR. In vivo results show good overall agreement between the methods, but some systematic deviations are present. Besides an expected dependence of T-2* on voxel size, T-1 values are systematically larger in the 3D approach than those obtained with the gold standard method. This behaviour might be due to imperfect spoiling, influencing each method differently. Results for H2O differ due to differences in the saturation of cerebrospinal fluid and partial volume effects. In addition, ground truth values of in vivo studies are unknown, even when comparing to in vivo gold standard methods. A detailed region-of-interest analysis for H2O and T-1 matches well published literature values.
引用
收藏
页数:21
相关论文
共 44 条
  • [21] Spin-lock based fast whole-brain 3D macromolecular proton fraction mapping of relapsing-remitting multiple sclerosis
    Hou, Jian
    Cai, Zongyou
    Chen, Weitian
    So, Tiffany Y.
    SCIENTIFIC REPORTS, 2024, 14 (01):
  • [22] Plaque Morphologic Quantification Reliability of 3D Whole-Brain Vessel Wall Imaging in Patients With Intracranial Atherosclerotic Disease: A Comparison With Conventional 3D Targeted Vessel Wall Imaging
    Zhang, Na
    Liu, Xinfeng
    Xiao, Jiayu
    Song, Shlee S.
    Fan, Zhaoyang
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2021, 54 (01) : 166 - 174
  • [23] A k-space sharing 3D GRASE pseudocontinuous ASL method for whole-brain resting-state functional connectivity
    Liang, Xiaoyun
    Tournier, Jacques-Donald
    Masterton, Richard
    Connelly, Alan
    Calamante, Fernando
    INTERNATIONAL JOURNAL OF IMAGING SYSTEMS AND TECHNOLOGY, 2012, 22 (01) : 37 - 43
  • [24] Comparison of T1-weighted 2D TSE, 3D SPGR, and two-point 3D Dixon MRI for automated segmentation of visceral adipose tissue at 3 Tesla
    Fallah, Faezeh
    Machann, Juergen
    Martirosian, Petros
    Bamberg, Fabian
    Schick, Fritz
    Yang, Bin
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2017, 30 (02) : 139 - 151
  • [25] Accelerated 3D whole-brain T1, T2, and proton density mapping: feasibility for clinical glioma MR imaging
    Pirkl, Carolin M.
    Nunez-Gonzalez, Laura
    Kofler, Florian
    Endt, Sebastian
    Grundl, Lioba
    Golbabaee, Mohammad
    Gomez, Pedro A.
    Cencini, Matteo
    Buonincontri, Guido
    Schulte, Rolf F.
    Smits, Marion
    Wiestler, Benedikt
    Menze, Bjoern H.
    Menzel, Marion I.
    Hernandez-Tamames, Juan A.
    NEURORADIOLOGY, 2021, 63 (11) : 1831 - 1851
  • [26] Comparison of T1-weighted 2D TSE, 3D SPGR, and two-point 3D Dixon MRI for automated segmentation of visceral adipose tissue at 3 Tesla
    Faezeh Fallah
    Jürgen Machann
    Petros Martirosian
    Fabian Bamberg
    Fritz Schick
    Bin Yang
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2017, 30 : 139 - 151
  • [27] Accelerated 3D whole-brain T1, T2, and proton density mapping: feasibility for clinical glioma MR imaging
    Carolin M. Pirkl
    Laura Nunez-Gonzalez
    Florian Kofler
    Sebastian Endt
    Lioba Grundl
    Mohammad Golbabaee
    Pedro A. Gómez
    Matteo Cencini
    Guido Buonincontri
    Rolf F. Schulte
    Marion Smits
    Benedikt Wiestler
    Bjoern H. Menze
    Marion I. Menzel
    Juan A. Hernandez-Tamames
    Neuroradiology, 2021, 63 : 1831 - 1851
  • [28] Detection of Small Metastatic Brain Tumors Comparison of 3D Contrast-Enhanced Whole-Brain Black-Blood Imaging and MP-RAGE Imaging
    Park, Jaeseok
    Kim, Jinna
    Yoo, Eunhye
    Lee, Hyunyeol
    Chang, Jong-Hee
    Kim, Eung Yeop
    INVESTIGATIVE RADIOLOGY, 2012, 47 (02) : 136 - 141
  • [29] Rapid MR Angiography Using 3D Gradient-echo Imaging and the Two-point Dixon Method to Evaluate Carotid Plaque
    Irie, Ryusuke
    Amemiya, Shiori
    Ueyama, Tsuyoshi
    Suzuki, Yuichi
    Takao, Hidemasa
    Abe, Osamu
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2023, 22 (03) : 373 - 378
  • [30] Whole-Brain Myelin Imaging Using 3D Double-Echo Sliding Inversion Recovery Ultrashort Echo Time (DESIRE UTE) MRI
    Ma, Ya-Jun
    Searleman, Adam C.
    Jang, Hyungseok
    Wong, Jonathan
    Chang, Eric Y.
    Corey-Bloom, Jody
    Bydder, Graeme M.
    Du, Jiang
    RADIOLOGY, 2020, 294 (02) : 362 - 374