Determination of liquiritigenin by ultra high performance liquid chromatography coupled with triple quadrupole mass spectrometry: Application to a linear pharmacokinetic study of liquiritigenin in rat plasma

被引:2
|
作者
Gu, Jie [1 ,2 ]
Li, Huan [1 ,2 ,3 ,4 ]
Pei, Ke [1 ,2 ]
Cai, Hui [4 ]
Qin, Kunming [1 ,2 ]
Zhang, Xinghai [1 ,2 ]
Zheng, Lijuan [1 ,2 ]
Liu, Xiao [1 ,2 ]
Cai, Yunqing [5 ]
Cai, Baochang [1 ,2 ]
机构
[1] Nanjing Univ TCM, Coll Pharm, Nanjing 210023, Jiangsu, Peoples R China
[2] Nanjing Univ Chinese Med, Jiangsu Key Lab Chinese Med Proc, Ctr Engn, State Minist Educ Standardizat Chinese Med Proc, Nanjing 210023, Jiangsu, Peoples R China
[3] ASTAR, Inst Bioengn & Nanotechnol, Singapore 138669, Singapore
[4] Temasek Polytech, Sch Appl Sci, Singapore 529757, Singapore
[5] Nanjing Med Univ, Sch Publ Hlth, Dept Nutr & Food Hyg, Nanjing 210029, Jiangsu, Peoples R China
关键词
Liquiritigenin; UHPLC-MS/MS; Intravenous administration; Linear pharmacokinetic study; 2; GLUCURONIDES; GLYCYRRHIZAE; INHIBITION; TISSUES; CELLS; LIVER; RADIX; M1; M2;
D O I
10.1016/j.jchromb.2014.09.002
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple, sensitive and rapid ultra high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method has been developed and validated for the quantification of liquiritigenin, a promising anti-tumor agent. Liquiritigenin and the internal standard were separated on an Agilent Extend C-18 column and eluted with a gradient mobile phase system of acetonitrile and water. The analysis was performed on a negative ionization electrospray mass spectrometer via multiple reaction monitoring (MRM). Transitions of m/z 255.0 -> 119.0 for liquiritigenin and m/z 269.0 -> 117.0 for the IS were monitored. One-step protein precipitation with acetonitrile was used to remove impurities and extract the analytes from plasma. The method had a chromatographic run time of 4.5 min and a good linearity in the range of 1-1000 ng/mL. The precision (R.S.D.) of intra-day and inter-day ranged from 4.54 to 10.65% and 5.94 to 13.81%, respectively; while the accuracy of intra-day and inter-day ranged from 104.06 to 109.28% and 94.98 to 112.05%. The recovery and stability were also within the acceptable limits. The validated method was applied to a linear pharmacokinetic study of liquiritigenin in rat plasma for the first time. (C) 2014 Published by Elsevier B.V.
引用
收藏
页码:120 / 125
页数:6
相关论文
共 50 条
  • [21] Rapid Simultaneous Determination of Five Amatoxins and Phallotoxins in Human Urine and Plasma by Ultra Performance Liquid Chromatography Coupled with Triple Quadrupole Mass Spectrometry
    Zhang Xiu-Yao
    Cai Xin-Xin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (01) : 39 - 44
  • [22] A sensitive bioanalytical method for quantitative determination of resiniferatoxin in rat plasma using ultra-high performance liquid chromatography coupled to tandem mass spectrometry and its application in pharmacokinetic study
    Sharma, Purnendu K.
    Avula, Bharathi
    Panda, Apoorva
    Wang, Yan-Hong
    Khan, Ikhlas A.
    Murthy, S. Narasimha
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2019, 165 : 284 - 291
  • [23] Determination of Paraquat in Rat Plasma by Ultra Performance Liquid Chromatography and its Application in a Pharmacokinetic Study
    Ma, Jianshe
    Chen, Mengchun
    Zhang, Yuan
    Zhang, Meiling
    Lin, Dan
    Wang, Xianqin
    LATIN AMERICAN JOURNAL OF PHARMACY, 2015, 34 (01): : 191 - 195
  • [24] Pharmacokinetic Study of Colchicine in Rat Plasma by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
    Wu, Mingdong
    Shen, Hongwei
    Yang, Suping
    Liu, Zezheng
    Xu, Mengzhi
    Wen, Congcong
    Gao, Gexin
    LATIN AMERICAN JOURNAL OF PHARMACY, 2016, 35 (01): : 140 - 145
  • [25] Pharmacokinetic Study of Tenacissoside H in Rat Plasma by Ultra Performance Liquid Chromatography Tandem Mass Spectrometry
    Lei, Xuwei
    Zhou, Genzhi
    Fan, Linyu
    Gu, Kaiwen
    Hu, Yue
    Zhang, Mauling
    Yuan, Qian
    Xu, Hongqin
    Zhang, Kaijia
    Ma, Jianshe
    LATIN AMERICAN JOURNAL OF PHARMACY, 2016, 35 (03): : 551 - 557
  • [26] Pharmacokinetic Study of Macitentan in Rat Plasma by Ultra Performance Liquid Chromatography-Tandem Mass Spectrometry
    Chen, Lianguo
    Yang, Suping
    Liu, Zezheng
    Zhang, Lijing
    Lin, Yingying
    Chen, Minle
    Zhou, Quan
    Wen, Congcong
    Wang, Xuebao
    LATIN AMERICAN JOURNAL OF PHARMACY, 2015, 34 (07): : 1411 - 1416
  • [27] Pharmacokinetic study of dendrobine in rat plasma by ultra-performance liquid chromatography tandem mass spectrometry
    Wang, Shuanghu
    Wu, Haiya
    Geng, Peiwu
    Lin, Yingying
    Liu, Zezheng
    Zhang, Lijing
    Ma, Jianshe
    Zhou, Yunfang
    Wang, Xianqin
    Wen, Congcong
    BIOMEDICAL CHROMATOGRAPHY, 2016, 30 (07) : 1145 - 1149
  • [28] Ultra high performance liquid chromatography coupled with triple quadrupole mass spectrometry and chemometric analysis of licorice based on the simultaneous determination of saponins and flavonoids
    Jiang, Zhenzuo
    Wang, Yuefei
    Zheng, Yunfeng
    Yang, Jing
    Zhang, Lei
    JOURNAL OF SEPARATION SCIENCE, 2016, 39 (15) : 2928 - 2940
  • [29] Determination of nimodipine in human plasma by ultra performance liquid chromatography-tandem mass spectrometry and pharmacokinetic application
    Qin, Feng
    Ma, Yuanyuan
    Wang, Yiqi
    Chen, Lingyun
    Wang, Dong
    Li, Famei
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2008, 46 (03) : 557 - 562
  • [30] Ultra-high-performance liquid chromatography for the determination of exenatide in monkey plasma by tandem quadrupole mass spectrometry
    Jin-Feng Zhang
    Chun-Jie Sha
    Yu Sun
    Yun-Yun Gai
    Ji-Ye Sun
    Jiang-Bin Han
    Xin Shao
    Chun-Na Sha
    You-Xin Li
    Wan-Hui Liu
    Journal of Pharmaceutical Analysis, 2013, 3 (04) : 235 - 240