Determination of liquiritigenin by ultra high performance liquid chromatography coupled with triple quadrupole mass spectrometry: Application to a linear pharmacokinetic study of liquiritigenin in rat plasma

被引:2
|
作者
Gu, Jie [1 ,2 ]
Li, Huan [1 ,2 ,3 ,4 ]
Pei, Ke [1 ,2 ]
Cai, Hui [4 ]
Qin, Kunming [1 ,2 ]
Zhang, Xinghai [1 ,2 ]
Zheng, Lijuan [1 ,2 ]
Liu, Xiao [1 ,2 ]
Cai, Yunqing [5 ]
Cai, Baochang [1 ,2 ]
机构
[1] Nanjing Univ TCM, Coll Pharm, Nanjing 210023, Jiangsu, Peoples R China
[2] Nanjing Univ Chinese Med, Jiangsu Key Lab Chinese Med Proc, Ctr Engn, State Minist Educ Standardizat Chinese Med Proc, Nanjing 210023, Jiangsu, Peoples R China
[3] ASTAR, Inst Bioengn & Nanotechnol, Singapore 138669, Singapore
[4] Temasek Polytech, Sch Appl Sci, Singapore 529757, Singapore
[5] Nanjing Med Univ, Sch Publ Hlth, Dept Nutr & Food Hyg, Nanjing 210029, Jiangsu, Peoples R China
关键词
Liquiritigenin; UHPLC-MS/MS; Intravenous administration; Linear pharmacokinetic study; 2; GLUCURONIDES; GLYCYRRHIZAE; INHIBITION; TISSUES; CELLS; LIVER; RADIX; M1; M2;
D O I
10.1016/j.jchromb.2014.09.002
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A simple, sensitive and rapid ultra high performance liquid chromatography tandem mass spectrometry (UHPLC-MS/MS) method has been developed and validated for the quantification of liquiritigenin, a promising anti-tumor agent. Liquiritigenin and the internal standard were separated on an Agilent Extend C-18 column and eluted with a gradient mobile phase system of acetonitrile and water. The analysis was performed on a negative ionization electrospray mass spectrometer via multiple reaction monitoring (MRM). Transitions of m/z 255.0 -> 119.0 for liquiritigenin and m/z 269.0 -> 117.0 for the IS were monitored. One-step protein precipitation with acetonitrile was used to remove impurities and extract the analytes from plasma. The method had a chromatographic run time of 4.5 min and a good linearity in the range of 1-1000 ng/mL. The precision (R.S.D.) of intra-day and inter-day ranged from 4.54 to 10.65% and 5.94 to 13.81%, respectively; while the accuracy of intra-day and inter-day ranged from 104.06 to 109.28% and 94.98 to 112.05%. The recovery and stability were also within the acceptable limits. The validated method was applied to a linear pharmacokinetic study of liquiritigenin in rat plasma for the first time. (C) 2014 Published by Elsevier B.V.
引用
收藏
页码:120 / 125
页数:6
相关论文
共 50 条
  • [11] Determination and Pharmacokinetics of Okanin in Rat Plasma by UltraHigh Performance Liquid Chromatography Coupled with Triple-Quadrupole Tandem Mass Spectrometry
    Shi, Yurui
    Chen, Rongda
    Xie, Jing
    Li, Li
    Liu, Guiming
    Zheng, Meizhu
    Zhang, Ning
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2020, 2020
  • [12] Simultaneous Determination of Eleven Rodenticides in Human Plasma and Urine Using Ultra Performance Liquid Chromatography Coupled With Triple Quadrupole Mass Spectrometry
    Cai Xin-Xin
    Zhang Xiu-Yao
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (10) : 1411 - 1416
  • [13] Determination of flurbiprofen in rat plasma using ultra-high performance liquid chromatography-tandem mass spectrometry and its application in a pharmacokinetic study
    Zhao, Xihong
    Lv, Chunjing
    Chen, Hong
    Qin, Feng
    Lu, Xiumei
    BIOMEDICAL CHROMATOGRAPHY, 2024, 38 (02)
  • [14] Simultaneous determination of tedizolid and linezolid in rat plasma by ultra performance liquid chromatography tandem mass spectrometry and its application to a pharmacokinetic study
    Yu, Hua-chen
    Pan, Chen-wei
    Xie, Qi-peng
    Zheng, Yi
    Hu, Yue-zheng
    Lin, Yi-mu
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2016, 1011 : 94 - 98
  • [15] Determination of Amanita Peptides in Human Plasma and Urine by High-Performance Liquid Chromatography Coupled with Triple Quadrupole Mass Spectrometry
    Wei, Jia-Hui
    Chen, Jia
    Wu, Bi-Dong
    Chen, Zuo-Hong
    Wu, Jian-Feng
    Xie, Jian-Wei
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2020, 48 (03) : 405 - 412
  • [16] Determination of Phillyrin in Rat Plasma by High Performance Liquid Chromatography-Tandem Mass Spectrometry and its Application to a Pharmacokinetic Study
    Cao, Huihui
    Peng, Jingdong
    Zhang, Lei
    LATIN AMERICAN JOURNAL OF PHARMACY, 2012, 31 (02): : 207 - 213
  • [17] Determination of zabofloxacin in rat plasma by liquid chromatography with mass spectrometry and its application to pharmacokinetic study
    Jin, Hyo-Eon
    Lee, Kyeong-Ryoon
    Kang, In-Hyul
    Chung, Suk-Jae
    Shim, Chang-Koo
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 54 (04) : 873 - 877
  • [18] Determination of Lamotrigine in Rat Plasma by Liquid Chromatography Mass Spectrometry and its Application to Pharmacokinetic Study
    Yang, Xuzhi
    Lin, Chongliang
    Cai, Jinzhang
    Zhang, Qingwei
    Lin, Guanyang
    LATIN AMERICAN JOURNAL OF PHARMACY, 2013, 32 (05): : 779 - 783
  • [19] Determination of bicuculline in rat plasma by liquid chromatography mass spectrometry and its application in a pharmacokinetic study
    Ma, Jianshe
    Lin, Chongliang
    Wen, Congcong
    Xiang, Zheng
    Yang, Xuezhi
    Wang, Xianqin
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2014, 953 : 143 - 146
  • [20] Determination of Gelsemine in Rat Plasma by Liquid Chromatography Mass Spectrometry and its Application to a Pharmacokinetic Study
    Tong, Shuhua
    Wang, Zhiyi
    Jiang, Shuomin
    Cai, Jinzhang
    LATIN AMERICAN JOURNAL OF PHARMACY, 2014, 33 (06): : 988 - 993