Biomechanical evaluation of distal biceps reconstruction with cortical button and interference screw fixation

被引:64
|
作者
Sethi, Paul [1 ]
Obopilwe, Elifho [2 ]
Rincon, Lina [2 ]
Miller, Seth [1 ]
Mazzocca, Augustus [2 ]
机构
[1] ONS Fdn Clin Res & Educ, Greenwich, CT 06830 USA
[2] Univ Connecticut, Ctr Hlth, MARB, Farmington, CT USA
关键词
distal biceps; repair; gap formation; cortical button; interference screw; TENDON REPAIR; 2-INCISION TECHNIQUE; SUTURE ANCHOR; BRACHII; RUPTURE;
D O I
10.1016/j.jse.2009.05.007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Hypothesis: Tension slide repair maintains the strength of the standard cortical button repair but reduces gap formation at the repair. Distal biceps tendon repair with a suspensory cortical button has yielded the strongest published repair, despite observed gap formation and tendon pistoning. The tension slide technique (TST) was described to reduce gap formation while maintaining the strength of cortical button repair. This study evaluates the biomechanics of the TST compared with previously described EndoButton (Smith & Nephew, Memphis, TN) repair and the TST with and without an interference screw. Materials and methods: The study used 20 matched specimens: 5 had a standard cortical button repair, and 5 had biceps repair with the TST. An additional 10 specimens underwent a TST, 5 with an interference screw and 5 without. All were cyclically loaded for 3600 cycles. Gap formation and load to failure were measured. Results: The mean (SD) load to failure for standard technique was at 389 (148) N vs 432 (66) N for the TST (P=.28). The mean (SD) gap formation was 2.79 (1.43) mm with the standard repair and 1.26 (0.61) mm with the TST (P=.03). The mean (SD) load to failure with TST repair was 436 (103) N without the interference screw and 439 (94) N (P=0.48) with the screw. The mean gap formation was 1.63 (1.09) mm without the screw and 1.45 (0.67) mm with the screw (P=.38.) Conclusion: This TST maintains the strength of the standard cortical button repair, but significantly reduces gap formation and motion at the repair site.
引用
收藏
页码:53 / 57
页数:5
相关论文
共 50 条
  • [41] The Intramedullary Cortical Button Technique for Distal Biceps Tendon Repair
    Buchholz, Arne
    Siebenlist, Sebastian
    OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2018, 26 (02) : 126 - 129
  • [42] Quadrupled Semitendinosus ACL Reconstruction Combining Cortical Button in Femur and Interference Screw in Tibia
    Pablo Martinez-Cano, Juan
    Marcela Zamudio-Castilla, Laura
    Andres Cuadros-Potes, Janio
    Catalina Ibarra-Mosquera, Laura
    Manuel Mejia-Lopez, Fernando
    ARTHROSCOPY TECHNIQUES, 2020, 9 (01): : E9 - E14
  • [43] Editorial Commentary : Biceps Tenodesis Fixation: Screw, Button, or None of the Above?
    Frank, Rachel M.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2020, 36 (05): : 1261 - 1263
  • [44] Distal Clavicle Fracture Repair Using Cortical Button Fixation With Coracoclavicular Ligament Reconstruction
    Yagnik, Gautam P.
    Porter, David A.
    Jordan, Charles J.
    ARTHROSCOPY TECHNIQUES, 2018, 7 (04): : E411 - E415
  • [45] Suprapectoral biceps tenodesis: A biomechanical comparison of a new "soft anchor" tenodesis technique versus interference screw biceps tendon fixation
    Baleani, Massimiliano
    Francesconi, Dunia
    Zani, Lorenzo
    Giannini, Sandro
    Snyder, Stephen J.
    CLINICAL BIOMECHANICS, 2015, 30 (02) : 188 - 194
  • [46] Biomechanical Comparison of Screw Fixation Versus a Cortical Button and Self-tensioning Suture for the Latarjet Procedure
    Provencher, Matthew T.
    Aman, Zachary S.
    LaPrade, Christopher M.
    Bernhardson, Andrew S.
    Moatshe, Gilbert
    Storaci, Hunter W.
    Chahla, Jorge
    Turnbull, Travis Lee
    LaPrade, Robert F.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2018, 6 (06):
  • [47] Failure of Primary Distal Biceps Repair After Cortical Button Fixation With Whipstitch Technique: A Root Cause Analysis
    Cheppalli, Naga
    Metikala, Sreenivasulu
    Leung, Eric
    Richter, Dustin L.
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2022, 14 (01)
  • [48] Biomechanical Comparison of All-Suture Anchor Fixation and Interference Screw Technique for Subpectoral Biceps Tenodesis
    Chiang, Florence L.
    Hong, Chih-Kai
    Chang, Chih-Hsun
    Lin, Cheng-Li
    Jou, I-Ming
    Su, Wei-Ren
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2016, 32 (07): : 1247 - 1252
  • [49] Distal Biceps Brachii Tendon Repairs A Single-Incision Technique Using a Cortical Button With Interference Screw Versus a Double-Incision Technique Using Suture Fixation Through Bone Tunnels
    Shields, Edward
    Olsen, Joshua R.
    Williams, Richard B.
    Rouse, Lucien
    Maloney, Michael
    Voloshin, Ilya
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2015, 43 (05): : 1072 - 1076
  • [50] High complication rate following distal biceps refixation with cortical button
    Marc Banerjee
    Sven Shafizadeh
    Bertil Bouillon
    Thorsten Tjardes
    Arasch Wafaisade
    Maurice Balke
    Archives of Orthopaedic and Trauma Surgery, 2013, 133 : 1361 - 1366