Biomechanical evaluation of distal biceps reconstruction with cortical button and interference screw fixation

被引:64
|
作者
Sethi, Paul [1 ]
Obopilwe, Elifho [2 ]
Rincon, Lina [2 ]
Miller, Seth [1 ]
Mazzocca, Augustus [2 ]
机构
[1] ONS Fdn Clin Res & Educ, Greenwich, CT 06830 USA
[2] Univ Connecticut, Ctr Hlth, MARB, Farmington, CT USA
关键词
distal biceps; repair; gap formation; cortical button; interference screw; TENDON REPAIR; 2-INCISION TECHNIQUE; SUTURE ANCHOR; BRACHII; RUPTURE;
D O I
10.1016/j.jse.2009.05.007
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Hypothesis: Tension slide repair maintains the strength of the standard cortical button repair but reduces gap formation at the repair. Distal biceps tendon repair with a suspensory cortical button has yielded the strongest published repair, despite observed gap formation and tendon pistoning. The tension slide technique (TST) was described to reduce gap formation while maintaining the strength of cortical button repair. This study evaluates the biomechanics of the TST compared with previously described EndoButton (Smith & Nephew, Memphis, TN) repair and the TST with and without an interference screw. Materials and methods: The study used 20 matched specimens: 5 had a standard cortical button repair, and 5 had biceps repair with the TST. An additional 10 specimens underwent a TST, 5 with an interference screw and 5 without. All were cyclically loaded for 3600 cycles. Gap formation and load to failure were measured. Results: The mean (SD) load to failure for standard technique was at 389 (148) N vs 432 (66) N for the TST (P=.28). The mean (SD) gap formation was 2.79 (1.43) mm with the standard repair and 1.26 (0.61) mm with the TST (P=.03). The mean (SD) load to failure with TST repair was 436 (103) N without the interference screw and 439 (94) N (P=0.48) with the screw. The mean gap formation was 1.63 (1.09) mm without the screw and 1.45 (0.67) mm with the screw (P=.38.) Conclusion: This TST maintains the strength of the standard cortical button repair, but significantly reduces gap formation and motion at the repair site.
引用
收藏
页码:53 / 57
页数:5
相关论文
共 50 条
  • [21] Biomechanical Evaluation of Open Suture Anchor Fixation Versus Interference Screw for Biceps Tenodesis
    Papp, Derek F.
    Skelley, Nathan W.
    Sutter, Edward G.
    Ji, Jong Hun
    Wierks, Carl H.
    Belkoff, Stephen M.
    McFarland, Edward G.
    ORTHOPEDICS, 2011, 34 (07) : E275 - E278
  • [22] The double intramedullary cortical button fixation for distal biceps tendon repair
    Sebastian Siebenlist
    Florian Elser
    Gunther H. Sandmann
    Arne Buchholz
    Frank Martetschläger
    Ulrich Stöckle
    Andreas Lenich
    Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19 : 1925 - 1929
  • [23] A comparison of cortical button with interference screw versus suture anchor techniques for distal biceps brachii tendon repairs
    Olsen, Joshua R.
    Shields, Edward
    Williams, Richard B.
    Miller, Richard
    Maloney, Michael
    Voloshin, Ilya
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2014, 23 (11) : 1607 - 1611
  • [24] Biomechanical Evaluation of Humerus Fracture After Subpectoral Biceps Tenodesis With Interference Screw Versus Unicortical Button
    Khalid, Mohammed A.
    Morris, Randal P.
    Black, Natalie
    Maassen, Nicholas H.
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2020, 36 (05): : 1253 - 1260
  • [25] Biomechanical evaluation of subpectoral biceps tenodesis: dual suture anchor versus interference screw fixation
    Tashjian, Robert Z.
    Henninger, Heath B.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2013, 22 (10) : 1408 - 1412
  • [26] Combined Button and Screw Technique for Distal Biceps Ruptures
    Rizk, Paul
    Morikawa, Daichi
    Coyner, Katherine
    OPERATIVE TECHNIQUES IN SPORTS MEDICINE, 2018, 26 (02) : 120 - 125
  • [27] Adjustable-length loop cortical button versus interference screw fixation in quadriceps tendon anterior cruciate ligament reconstruction - A biomechanical in vitro study
    Karkosch, Roman Frederik
    Ettinger, Max
    Bachmaier, Samuel
    Wijdicks, Coen A.
    Smitha, Tomas
    CLINICAL BIOMECHANICS, 2018, 60 : 60 - 65
  • [28] Biomechanical evaluation of a new ulnar collateral ligament reconstruction technique with interference screw fixation
    Ahmad, CS
    Lee, TQ
    ElAttrache, NS
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2003, 31 (03): : 332 - 337
  • [29] A Combined Technique for Distal Biceps Repair Using a Soft Tissue Button and Biotenodesis Interference Screw
    Heinzelmann, Andrew D.
    Savoie, Felix H., III
    Ramsey, J. Randall
    Field, Larry D.
    Mazzocca, Augustus D.
    AMERICAN JOURNAL OF SPORTS MEDICINE, 2009, 37 (05): : 989 - 994
  • [30] Cortical suture button fixation vs. bicortical screw fixation in the Latarjet procedure: a biomechanical comparison
    Williams, Robert C.
    Morris, Randal P.
    El Beaino, Marc
    Maassen, Nicholas H.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2020, 29 (07) : 1470 - 1478