A novel microwave air heater integrated with thermal energy storage

被引:3
|
作者
Yek, Peter Nai Yuh [1 ,2 ]
Lau, Chui Eng [2 ]
Lau, Sie Yee [2 ]
Ting, Tiew Wei [2 ]
Peng, Wanxi [1 ]
Liew, Rock Keey [3 ]
Guerriero, Giulia [4 ]
Chang, Jo-Shu [5 ,6 ]
Park, Young-Kwon [7 ]
Lam, Su Shiung [1 ,8 ]
机构
[1] Henan Agr Univ, Sch Forestry, Henan Prov Int Collaborat Lab Forest Resources Ut, Zhengzhou 450002, Peoples R China
[2] Univ Technol Sarawak, Ctr Res Innovat & Sustainable Dev, 1 Jalan Univ, Sibu, Malaysia
[3] NV WESTERN PLT, George Town, Malaysia
[4] Federico II Univ Naples, Dept Biol, Naples, Italy
[5] Natl Cheng Kung Univ, Dept Chem Engn, Tainan, Taiwan
[6] Tunghai Univ, Dept Chem & Mat Engn, Taichung, Taiwan
[7] Univ Seoul, Sch Environm Engn, 163 Seoulsiripdaero, Seoul 02504, South Korea
[8] Univ Malaysia Terengganu, Higher Inst Ctr Excellence HICoE, Inst Trop Aquaculture & Fisheries AKUATROP, Kuala Nerus, Malaysia
关键词
activated carbon; heat transfer; helical coil; microwave; thermal energy storage; HELICALLY COILED TUBE; ACTIVATED CARBON; FRYING OIL; PYROLYSIS; FLOW; LAMINAR; PUMP;
D O I
10.1002/er.7912
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Conventional heater is limited by the time and energy-consuming design, showing high energy loss and causing a negative impact to the environment. A novel air heater integrated with microwave heating and activated carbon (AC) as thermal energy storage has been developed in this study to investigate the heat transfer efficiency in a helical coil. Microwave radiation provides volumetric heating to the AC, which acts as a microwave absorbent to absorb and convert microwave energy into heat energy for storage and subsequently heating the helical coil that in turn heats the air indirectly. The helical coil exerted centrifugal force and induced secondary flow to significantly enhance the heat transfer. Microwave radiation induced a high heating rate of 30 degrees C/min to heat the AC. Low heat loss (6.12 degrees C/min) was shown during the cooling down of AC, indicating high heat retention by the AC. Then, the convective heat transfer between helical coil and air with over a range of AC temperatures was examined. The highest overall heat transfer coefficient (U-0) and coefficient of performance (COP) with various AC temperatures were recorded at 310.815 W/m(2)center dot degrees C and 3.958, respectively, at 50 L/min of air flow rate. Nusselt number, Reynolds number, and Dean number were increased with higher air flow rate. The experimental results showed good agreement with literature where convective heat transfer in the helical coil is more efficient at the high-temperature region as well as when higher flow rate was applied. The use of microwave air heater shows a potentially high efficiency of energy-saving with capacity to generate hot air at 100 degrees C to 250 degrees C in about 26 min after switching on the microwave oven.
引用
收藏
页码:19269 / 19277
页数:9
相关论文
共 50 条
  • [41] Design and thermal performance evaluation of a novel solar air heater
    Saxena, Abhishek
    Srivastava, Ghanshyam
    Tirth, Vineet
    RENEWABLE ENERGY, 2015, 77 : 501 - 511
  • [42] PERFORMANCE EVALUATION OF A SOLAR WATER HEATER INTEGRATED WITH BUILT-IN THERMAL ENERGY STORAGE VIA POROUS MEDIA
    Majdi, Hasan S.
    Abed, Azher M.
    Habeeb, Laith J.
    FRONTIERS IN HEAT AND MASS TRANSFER, 2021, 17
  • [43] Performance evaluation of a solar water heater integrated with built-In thermal energy storage via porous media
    Majdi H.S.
    Abed A.M.
    Habeeb L.J.
    Frontiers in Heat and Mass Transfer, 2021, 17
  • [44] Effect of the storage tank thermal insulation on the thermal performance of an integrated collector storage solar water heater (ICSSWH)
    Chaabane, Monia
    Mhiri, Hatem
    Bournot, Philippe
    HEAT AND MASS TRANSFER, 2014, 50 (10) : 1335 - 1341
  • [45] Numerical investigation of a solar air heater comprising longitudinally finned absorber plate and thermal energy storage system
    Josyula, Tejaswi
    Singh, Satyender
    Dhiman, Prashant
    JOURNAL OF RENEWABLE AND SUSTAINABLE ENERGY, 2018, 10 (05)
  • [46] Enhanced performance assessment of an integrated evacuated tube and flat plate collector solar air heater with thermal storage material
    El-Fakharany, Magda K.
    Abo-Samra, Aly-Eldeen A.
    Abdelmaqsoud, A. M.
    Marzouk, S. A.
    APPLIED THERMAL ENGINEERING, 2024, 243
  • [47] Effect of the storage tank thermal insulation on the thermal performance of an integrated collector storage solar water heater (ICSSWH)
    Monia Chaabane
    Hatem Mhiri
    Philippe Bournot
    Heat and Mass Transfer, 2014, 50 : 1335 - 1341
  • [48] Optimal Dynamic Dispatch of Wind Integrated Thermal Generators with Compressed Air Energy Storage
    Bhatt, Akanksha
    Pandit, Manjaree
    Shrivastava, Aayush
    Dubey, Hari Mohan
    INTERNATIONAL JOURNAL OF RENEWABLE ENERGY RESEARCH, 2014, 4 (03): : 689 - 697
  • [49] Experimental energy and exergy analysis of a flat plate solar air heater with a new design of integrated sensible heat storage
    Kalaiarasi, G.
    Velraj, R.
    Swami, Muthusamy V.
    ENERGY, 2016, 111 : 609 - 619
  • [50] A review of thermal energy storage in compressed air energy storage system
    Zhou, Qian
    Du, Dongmei
    Lu, Chang
    He, Qing
    Liu, Wenyi
    ENERGY, 2019, 188