Changes in biofilm composition and microbial water quality in drinking water distribution systems by temperature increase induced through thermal energy recovery

被引:14
|
作者
Ahmad, Jawairia Imtiaz [1 ,3 ]
Dignum, Marco [2 ]
Liu, Gang [1 ,4 ]
Medema, Gertjan [1 ,5 ,6 ]
van der Hoek, Jan Peter [1 ,2 ]
机构
[1] Delft Univ Technol, Fac Civil Engn & Geosci, Dept Water Management, Sanit Engn, POB 5048, NL-2600 GA Delft, Netherlands
[2] Waternet, Korte Ouderkerkerdijk 7, NL-1096 AC Amsterdam, Netherlands
[3] Natl Univ Sci & Technol, Sch Civil & Environm Engn, Inst Environm Sci & Engn, H-12 Sect, Islamabad, Pakistan
[4] Chinese Acad Sci, Res Ctr Ecoenvironm Sci, Key Lab Drinking Water Sci & Technol, Beijing 100085, Peoples R China
[5] KWR Water Res Inst, POB 1072, NL-3430 BB Nieuwegein, Netherlands
[6] Michigan State Univ, 1405 S Harrison Rd, E Lansing, MI 48823 USA
关键词
Cold recovery; Drinking water distribution system; Temperature increase; Microbial water quality; Primary colonizers; Microbial source tracking; Biofilm; NUCLEIC-ACID-CONTENT; BACTERIAL COMMUNITIES; BULK WATER; DYNAMICS; CARBON;
D O I
10.1016/j.envres.2020.110648
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Drinking water distribution systems (DWDSs) have been thoroughly studied, but the concept of thermal energy recovery from DWDSs is very new and has been conceptualized in the past few years. Cold recovery results in a temperature increase of the drinking water. Its effects on drinking water quality and biofilm development are unclear. Hence, we studied both bulk water and biofilm phases for 232 days in two parallel pilot scale distribution systems with two temperature settings after cold recovery, 25 degrees C and 30 degrees C, and compared these with a reference pilot system without cold recovery. In all three pilot distributions systems (DSs) our results showed an initial increase in biomass (ATP) in the biofilm phase, along with occurrence of primary colonizers (Betapro-teobacteriales) and subsequently a decrease in biomass and an increasing relative abundance of other microbial groups (amoeba resisting groups; Xanthobacteraceae, Legionellales), including those responsible for EPS formation in biofilms (Sphingomonadaceae). The timeline for biofilm microbial development was different for the three pilot DSs: the higher the temperature, the faster the development took place. With respect to the water phase within the three pilot DSs, major microbial contributions came from the feed water (17-100%) and unkown sources (2-80%). Random contributions of biofilm (0-70%) were seen between day 7-77. During this time period sixfold higher ATP concentration (7-11 ng/l) and two-fold higher numbers of high nucleic acid cells (5.20-5.80 x 10(4) cells/ml) were also observed in the effluent water from all three pilot DSs, compared to the feed water. At the end of the experimental period the microbial composition of effluent water from three pilot DSs revealed no differences, except the presence of a biofilm related microbial group (Sphingomonadaceae), within all three DSs compared to the feed water. In the biofilm phase higher temperatures initiated the growth of primary colonizing bacteria but this did not lead to differences in microbial diversity and composition at the end of the experimental period. Hence, we propose that the microbiological water quality of DWDSs with cold recovery should be monitored more frequently during the first 2-3 months of operation.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Assessing the Effect of Changing Ambient Air Temperature on Water Temperature and Quality in Drinking Water Distribution Systems
    Lai, Yuchuan
    Dzombak, David A.
    WATER, 2021, 13 (14)
  • [22] Modelling bacteriological water quality in drinking water distribution systems
    Piriou, P
    Dukan, S
    Kiene, L
    WATER SCIENCE AND TECHNOLOGY, 1998, 38 (8-9) : 299 - 307
  • [23] Threats Associated with the Presence of Biofilm in Drinking Water Distribution Systems
    Swiderska-Broz, Maria
    OCHRONA SRODOWISKA, 2012, 34 (01): : 9 - 14
  • [24] Influence of phosphorus on biofilm accumulation in drinking water distribution systems
    Kasahara, S
    Maeda, K
    Ishikawa, M
    4TH WORLD WATER CONGRESS: INNOVATION IN DRINKING WATER TREATMENT, 2004, 4 (5-6): : 389 - 398
  • [25] Climate-change-induced energy and water use increase in water distribution systems
    Truettner, Conrad B.
    Barkdoll, Brian D.
    URBAN WATER JOURNAL, 2022, 19 (05) : 492 - 498
  • [26] Applied Research Note: Microbial composition of the biofilm of poultry drinking water system
    Ogundipe, T. T.
    Beitia, S.
    Obe, T.
    JOURNAL OF APPLIED POULTRY RESEARCH, 2024, 33 (02):
  • [27] Effect of free chlorine application on microbial quality of drinking water in chloraminated distribution systems
    Rosenfeldt, Erik J.
    Baeza, Carolina
    Knappe, Detlef R. U.
    JOURNAL AMERICAN WATER WORKS ASSOCIATION, 2009, 101 (10): : 60 - 70
  • [28] Particle related water quality prediction for drinking water distribution systems
    Ripl, K.
    Lerch, A.
    Uhl, W.
    INTEGRATING WATER SYSTEMS, 2010, : 415 - 421
  • [29] Copper corrosion in drinking water distribution systems - the influence of water quality
    Dept of Inorganicf Chemistry, University of Goteborg, Sweden
    Corros Sci, 6 (1119-1132):
  • [30] Copper corrosion in drinking water distribution systems - The influence of water quality
    Broo, AE
    Berghult, B
    Hedberg, T
    CORROSION SCIENCE, 1997, 39 (06) : 1119 - 1132