Evaluation of a Real-Time Hybrid Three-Dimensional Echo and X-Ray Imaging System for Guidance of Cardiac Catheterisation Procedures

被引:0
|
作者
Housden, R. J. [1 ]
Arujuna, A. [1 ,2 ,3 ]
Ma, Y. [1 ]
Nijhof, N. [3 ]
Gijsbers, G. [3 ]
Bullens, R. [3 ]
O'Neill, M. [1 ,2 ]
Cooklin, M. [2 ]
Rinaldi, C. A. [2 ]
Gill, J. [2 ]
Kapetanakis, S. [2 ]
Hancock, J. [2 ]
Thomas, M. [2 ]
Razavi, R. [1 ,2 ]
Rhode, K. S. [1 ]
机构
[1] Kings Coll London, Div Imaging Sci & Biomed Engn, London WC2R 2LS, England
[2] Guys & St Thomas NHS Fdn Trust, Dept Cardiol, London, England
[3] Philips Healthcare, Intervent Xray, Best, Netherlands
来源
MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2012, PT II | 2012年 / 7511卷
关键词
Intervention guidance; image fusion; registration; X-ray fluoroscopy; 4D ultrasound; REGISTRATION; FLUOROSCOPY;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Minimally invasive cardiac surgery is made possible by image guidance technology. X-ray fluoroscopy provides high contrast images of catheters and devices, whereas 3D ultrasound is better for visualising cardiac anatomy. We present a system in which the two modalities are combined, with a trans-esophageal echo volume registered to and overlaid on an X-ray projection image in real-time. We evaluate the accuracy of the system in terms of both temporal synchronisation errors and overlay registration errors. The temporal synchronisation error was found to be 10% of the typical cardiac cycle length. In 11 clinical data sets, we found an average alignment error of 2.9 mm. We conclude that the accuracy result is very encouraging and sufficient for guiding many types of cardiac interventions. The combined information is clinically useful for placing the echo image in a familiar coordinate system and for more easily identifying catheters in the echo volume.
引用
收藏
页码:25 / 32
页数:8
相关论文
共 50 条
  • [21] 3-DIMENSIONAL IMAGING OF X-RAY AND GAMMA-RAY OBJECTS IN REAL-TIME
    YIN, LI
    TROMBKA, JI
    SELTZER, SM
    APPLIED OPTICS, 1980, 19 (17) : 2952 - 2956
  • [22] Three-dimensional X-ray imaging system and its application in power equipment
    Zhong, Fei
    Zhang, Fumu
    Zhang, Liping
    Hao, Ming
    INSIGHT, 2019, 61 (10) : 572 - 576
  • [23] Photoacoustic tomography system for noninvasive real-time three-dimensional imaging of epilepsy
    Wang, Bo
    Xiang, Liangzhong
    Jiang, Max S.
    Yang, Jianjun
    Zhang, Qizhi
    Carney, Paul R.
    Jiang, Huabei
    BIOMEDICAL OPTICS EXPRESS, 2012, 3 (06): : 1427 - 1432
  • [24] Real-time three-dimensional optoacoustic imaging using an acoustic lens system
    Niederhauser, JJ
    Jaeger, M
    Frenz, M
    APPLIED PHYSICS LETTERS, 2004, 85 (05) : 846 - 848
  • [25] Real-time radio-transparent dosimeter for X-ray imaging system
    Staub, D
    Cailleret, J
    Guyonnet, JL
    Le, TD
    Wurtz, J
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 525 (1-2): : 303 - 307
  • [26] Rapid Image Registration of Three-Dimensional Transesophageal Echocardiography and X-ray Fluoroscopy for the Guidance of Cardiac Interventions
    Gao, Gang
    Penney, Graeme
    Gogin, Nicolas
    Cathier, Pascal
    Arujuna, Aruna
    Wright, Matt
    Caulfield, Dennis
    Rinaldi, Aldo
    Razavi, Reza
    Rhode, Kawal
    INFORMATION PROCESSING IN COMPUTER-ASSISTED INTERVENTIONS, 2010, 6135 : 124 - +
  • [27] Three-TFT image sensor for real-time digital X-ray imaging
    Safavian, N
    Chaji, GR
    Nathan, A
    Rowlands, JA
    ELECTRONICS LETTERS, 2006, 42 (03) : 150 - 151
  • [28] Integration of X-Ray and Optical Tomography for Precision Radiation Guidance and Real-Time Treatment Evaluation
    Yang, Y.
    Wang, K.
    Eslami, S.
    Iordachita, I.
    Patterson, M.
    Wong, J.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [29] Three-Dimensional X-Ray Imaging and Analysis of Fungi on and in Wood
    Van den Bulcke, Jan
    Boone, Matthieu
    Van Acker, Joris
    Van Hoorebeke, Luc
    MICROSCOPY AND MICROANALYSIS, 2009, 15 (05) : 395 - 402
  • [30] Coherent three-dimensional X-ray cryo-imaging
    Robinson, Ian
    IUCRJ, 2015, 2 : 477 - 478