Evaluation of a Real-Time Hybrid Three-Dimensional Echo and X-Ray Imaging System for Guidance of Cardiac Catheterisation Procedures

被引:0
|
作者
Housden, R. J. [1 ]
Arujuna, A. [1 ,2 ,3 ]
Ma, Y. [1 ]
Nijhof, N. [3 ]
Gijsbers, G. [3 ]
Bullens, R. [3 ]
O'Neill, M. [1 ,2 ]
Cooklin, M. [2 ]
Rinaldi, C. A. [2 ]
Gill, J. [2 ]
Kapetanakis, S. [2 ]
Hancock, J. [2 ]
Thomas, M. [2 ]
Razavi, R. [1 ,2 ]
Rhode, K. S. [1 ]
机构
[1] Kings Coll London, Div Imaging Sci & Biomed Engn, London WC2R 2LS, England
[2] Guys & St Thomas NHS Fdn Trust, Dept Cardiol, London, England
[3] Philips Healthcare, Intervent Xray, Best, Netherlands
来源
MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2012, PT II | 2012年 / 7511卷
关键词
Intervention guidance; image fusion; registration; X-ray fluoroscopy; 4D ultrasound; REGISTRATION; FLUOROSCOPY;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
Minimally invasive cardiac surgery is made possible by image guidance technology. X-ray fluoroscopy provides high contrast images of catheters and devices, whereas 3D ultrasound is better for visualising cardiac anatomy. We present a system in which the two modalities are combined, with a trans-esophageal echo volume registered to and overlaid on an X-ray projection image in real-time. We evaluate the accuracy of the system in terms of both temporal synchronisation errors and overlay registration errors. The temporal synchronisation error was found to be 10% of the typical cardiac cycle length. In 11 clinical data sets, we found an average alignment error of 2.9 mm. We conclude that the accuracy result is very encouraging and sufficient for guiding many types of cardiac interventions. The combined information is clinically useful for placing the echo image in a familiar coordinate system and for more easily identifying catheters in the echo volume.
引用
收藏
页码:25 / 32
页数:8
相关论文
共 50 条
  • [1] Real-time three dimensional intracardiac echocardiography for guidance of cardiac interventional procedures
    Lee, W
    Light, ED
    Idriss, SF
    Dixon-Tulloch, E
    Wolf, PD
    Smith, SW
    2001 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 AND 2, 2001, : 1307 - 1310
  • [2] Integration of real-time X-ray fluoroscopy, rotational X-ray imaging and real-time catheter tracking for improved navigation in interventional cardiac electrophysiology procedures
    Manzke, R.
    Chan, R. C.
    Shechter, G.
    Sokka, S.
    Stanton, D.
    Malchano, Z. J.
    Rasche, V.
    Reddy, V. Y.
    MEDICAL IMAGING 2006: VISUALIZATION, IMAGE-GUIDED PROCEDURES, AND DISPLAY, 2006, 6141
  • [3] EVALUATION OF A REAL-TIME DISPLAY FOR SKIN DOSE MAP IN CARDIAC CATHETERISATION PROCEDURES
    Sanchez, Roberto M.
    Vano, Eliseo
    Fernandez, Jose M.
    Escaned, Javier
    RADIATION PROTECTION DOSIMETRY, 2015, 165 (1-4) : 240 - 243
  • [4] Optical Microscanning X-ray Real-time Imaging System
    Gao Meijing
    Wu Weilong
    Xu Wei
    Wang Jingyuan
    PROCEEDINGS OF THE 2014 INTERNATIONAL CONFERENCE ON MECHATRONICS, ELECTRONIC, INDUSTRIAL AND CONTROL ENGINEERING, 2014, 5 : 1136 - 1140
  • [5] Monoscopic X-Ray Imaging for Real-Time Three-Dimensional Target Localization Using Multiple Internal Fiducial Markers
    Miyamoto, N.
    Suzuki, R.
    Takao, S.
    Matsuura, T.
    Fujii, T.
    Hirayama, S.
    Koyano, H.
    Shimizu, S.
    Umegaki, K.
    Shirato, H.
    MEDICAL PHYSICS, 2017, 44 (06) : 3203 - 3203
  • [6] Hybrid echo and x-ray image guidance for cardiac catheterization procedures by using a robotic arm: a feasibility study
    Ma, YingLiang
    Penney, Graeme P.
    Bos, Dennis
    Frissen, Peter
    Rinaldi, C. Aldo
    Razavi, Reza
    Rhode, Kawal S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2010, 55 (13): : N371 - N382
  • [7] Three-dimensional image fusion of CTA and angiography for real-time guidance during neurointerventional procedures
    Zhang, Qiang
    Sun, Qi
    Zhang, Yiqi
    Zhang, Hao
    Shan, Tonghui
    Han, Jingfeng
    Pan, Wenlong
    Gu, Chuanqi
    Xu, Ruxiang
    JOURNAL OF NEUROINTERVENTIONAL SURGERY, 2017, 9 (03) : 302 - U96
  • [8] Three-dimensional real-time imaging of cardiac cell motions in living embryos
    Lu, Jian
    Pereira, Francisco
    Fraser, Scott E.
    Gharib, Morteza
    JOURNAL OF BIOMEDICAL OPTICS, 2008, 13 (01)
  • [9] Real-time X-ray imaging data acquisition system for pnCCD
    Huo, Jia
    Zhao, Xiaofan
    Cui, Weiwei
    Wang, Yusa
    Wang, Hao
    Chen, Yong
    Guangxue Jingmi Gongcheng/Optics and Precision Engineering, 2024, 32 (21): : 3166 - 3173
  • [10] Real-time pose estimation of devices from x-ray images: Application to x-ray/echo registration for cardiac interventions
    Hatt, Charles R.
    Speidel, Michael A.
    Raval, Amish N.
    MEDICAL IMAGE ANALYSIS, 2016, 34 : 101 - 108